1、 Instruction Manual Model Y5020 Current Shunt P/N 516591 September 1979 RadioFans.CN 收音机爱 好者资料库 Y5020 RadioFans.CN 收音机爱 好者资料库 Y5020 1 INTRODUCTION The Model Y5020 is a precision, four-terminal, current shunt designed for use in calibrating ac/dc current sources in the range of 0 to 20 amps, do to 5
2、kHz. The shunt is housed in a forced-air cooled, PTI (Portable Test Instrument) case. This case is compatible with all instruments in the Fluke PTI product line and can be stacked with other PTI products to form a portable test system. Forced-air cooling is accomplished by a fan mounted on the rear
3、panel. Air is pulled in through the fan, passed over the shunt, and exhausted through the rear panel. Power for the fan is derived from the power line. Two voltage configurations are available, 115 or 230V ac 10%, 50 to 60 Hz. Four front panel terminals provide electrical access to the shunt; two ar
4、e current input terminals and two are voltage output (sense) terminals. When the shunt is connected into a circuit and operating at its maximum current limit (20 amps), the input connections and the shunt present a burden voltage of less than 0.25V dc. SPECIFICATIONS Specifications for the Y5020 Cur
5、rent Shunt are given in Table 1. INSTALLATION The Y5020 PTI case is designed to stack with other Fluke instruments in the PTI product line. Use the following procedure to stack the Y5020 with the other PTI instruments. 1. Locate and pull the black latches on both sides of the unit to their extended
6、position. 2. Place the unit on top of the PTI stack with the front panel toward the front of the stack. 3. When the unit is properly seated push both latches to the in position. This will lock the Y5020 to the stack. CONTROLS AND CONNECTORS The front- and rear-panel controls and connectors on the Y5
7、020 are shown in Figure 1 and described in Table 2. OPERATING NOTES Input Power Line power requirements for the Y5020 are specified on a decal located on the bottom side of the unit. These include line voltage requirements (115V or 230V ac 10%, 50 to 60 Hz) and replacement fuse types. Input power is
8、 used solely to power an internal cooling fan. A front panel POWER switch allows the fan to be turned on and off. Fuse Replacement The Y5020 includes a fuse to protect the ac power line from an accidental overload. If replacement is required, use a 1/8 amp, 250 volt (AGC) fuse. Use the following pro
9、cedure to replace the fuse: 1. Set the POWER switch to OFF and disconnect the unit from line power. 2. Locate the fuse holder on the rear panel. Table 1. Y5020 Specifications NOMINAL RESISTANCE ACCURACY OF CALIBRATION VALUE DC DC to 1 kHz 1 kHz to 5 kHz STABILITY OF CALIBRATION VALUE MAXIMUM CURRENT
10、 BURDEN VOLTAGE AT 20 AMPS TEMPERATURE COEFFICIENT POWER COEFFICIENT POWER PROTECTION CLASS 3 0.01 1% .01% .01% .025% .035% (30 ppm per 6 months) 20A dc or rms ac Less than 0.25V 0.001% per C 0.005% at 20 amps 115V ac 10% or 230V ac 10%, 11 watts for cooling fan. Relates solely to insulating or grou
11、nding properties as defined in IEC 348. RadioFans.CN 收音机爱 好者资料库 Y5020 2 12 6 54 3 Figure 1. Controls and Connectors Y5020 3 Table 2. Controls and Connectors REF NO. NAMEFUNCTION 1VOLTAGE OUTPUT TerminalsA pair of binding posts that serve as the sense connections to the four- terminal shunt. The maxi
12、mum sense voltage at 20 amps is 0.2 volts. 2CURRENT INPUT TerminalsTwo binding posts that serve as the current input connections to the shunt. The maximum current rating for the shunt is 20 amps. 3POWER SwitchA push-push type switch used to switch the cooling fan on and off. 4Input Power ConnectorA
13、three-prong connector used to connect the instrument (via the power cord) to line power. 5Fuse HolderHolds the line power fuse for the cooling fan. The fuse provides ac input protection from overloads. 6Fan Intake and Exhaust PortsCooling air for the shunt is pulled in through the rear-right port (i
14、ntake) and exhausted through the rear-left port. The fan is located behind the intake port. 3. Release the fuse by pressing in on the fuse cap and turning it 1/8 of a turn counterclockwise. Use a suitable screwdriver. CAUTION To avoid fire hazard use only a 1/8 amp, 250 volt (AGC) fuse replacement.
15、4. Install the new fuse in the fuse cap and install both in the fuse holder. Forced-Air Cooling CAUTION To ensure the accuracy specifications of the shunt, do not apply input current to the Y5020 unless the cooling fan is energized. The Y5020 is equipped with an internal cooling fan to ensure the ac
16、curacy and stability of the shunt over its operating range (0 to 20 amps). The fan pulls the air in through the rear panel, passes it over the shunt, and exhausts it through the rear panel. Power for the fan is derived from the ac power line. A front panel POWER switch is used to turn the fan off an
17、d on. Four-Terminal Measurements The Y5020 is a four-terminal current shunt. Two terminals (CURRENT INPUT) are used to carry the current to be measured. The other two (VOLTAGE OUTPUT) are voltage sense terminals and are not designed to carry any measurement current. These sense terminals are connect