1657 RLC Digibridge 电路图.pdf
《1657 RLC Digibridge 电路图.pdf》由会员分享,可在线阅读,更多相关《1657 RLC Digibridge 电路图.pdf(57页珍藏版)》请在收音机爱好者资料库上搜索。
1、1657 RLC Digibridge Instruction Manual Foun 1657-0120-07/B1 QuadTech, Inc., 1992 5 Clock Tower Place, 210 East Maynard, Massachusetts, U.S.A. 01754 January, 1997 Tel. 978-461-2100 800-253-1230 (Sales) 800-253-1230 (Service) Fax. 978-461-4295 The material in this manual is for informational purposes
2、only and is subject to change, without notice. QuadTech assumes no responsibility for any error or for consequential damages that may result from the misinterpretation of any procedures in this publication. Contents Instruction Manual Changes Specifications Warranty Introduction -Section 1 Installat
3、ion -Section 2 Operation -Section 3 Theory -Section 4 Service and Maintenance -Section 5 Parts Lists and Diagrams -Section 6 Product will be marked with this symbol (ISO#3684) when it is necessary for the user to refer to the instruction manual in order to prevent injury or equipment damage. RadioFa
4、ns.CN 收音机爱 好者资料库 These two supplementary pages contain information of improvements or modifications not documented in the current manual. All references to GenRad in the manual now apply to QuadTech, Inc. Page -Specifications (Power L and Q series or parallel; C and D series or parallel. All measure
5、ment modes are pushbutton selectable. Displays: LED-type numerical display with automatically positioned decimal points and illumination of units. For R LC, five digits (99999) and simultaneously for DQ, four digits (9999). Measurement Speed: Greater than 3 measurements per second. / Test frequencie
6、s: Pushbutton selection between 2. Accuracy re panel legends: +2%, -.01%. Actual frequencies: for 1657-9700, 1020.0 Hz +/- .01% (panel legend 1 kHz) and 120.00 Hz +/- .01%; for 1657.9800,1000.0 and 100.00 Hz +/- .01%. Applied Voltage: 0.3 V rms maximum. Ranges: Pushbutton selection with automatic fr
7、ont-panel guidance. Three basic ranges (best accuracy, see table) of 2 decades each, for each parameter. Automatic extensions to min and max, as tabulated. SERVICE POLICY QuadTech policy is to maintain product repair capability for a period of five (5) years after original shipment and to make this
8、capability available at the then prevailing schedule of charges. Table of Contents 1.1 PURPOSE 1-1 1.2 GENERAL DESCRIPTION 1-1 1.3 CONTROLS, INDICATORS, AND CONNECTORS 1-1 1.4 ACCESSORIES 1-1 1.1 PURPOSE. in keeping with the long-life circuitry inside. Glass-epoxy The 1657 Digibridge digital impedan
9、ce meter embodies circuit boards interconnect and support high-quality com use of a microprocessor and other LSI circuitry to ponents to assure years of dependability. provide excellent performance at low cost. Adaptability to any common ac power line is assured by A few clearly labeled pushbuttons
10、and the versatile the removable power cord and the convenient line-voltage built-in test fixture make this instrument a model for con- switch. Safety is enhanced by the fused, isolating power venience. Measurement results are clearly shown with dec- transformer and the 3-wire power connection. A com
11、pre imal points and units, which are automatically presented to hensive functional description is given in Theory, Section 4 assure correctness. Display resolution is 5 digits for R, C, Electrical and physical characteristics are listed in Specifi and L (4 for D or Q) and the basic accuracy is 0.2%.
12、 cations at the front of this manual, dimensions in Installa Long-term accuracy and reliability are assured by the tion, Section 2. Controls are described below, and their use measurement system. It makes these accurate analog in Operation, Section 3. measurements over many decades of impedance with
13、out a single calibration or trimming adjustment (not even in 1.3 CONTROLS, INDICATORS, AND CONNECTORS. original manufacture). . The built-in test fixture, with a pair of plug-in adaptors, Figure :-1 shows the front panel conrols and indicators. receives any common component part (axial-lead or radia
14、l- Table 1-1 identifies them with descriptions and functions. lead) so easily that insertion of the DUT is a one-hand Similarily, Figure 1-2 shows the rear panel and Table 1-2 identifies t . . I . Identifies and describes the rear panel controls and connec operation. True 4-terminal connections are
15、made automat .ically. Extender cables and other accessories are available and describes the rear panel controls and connectors. for measurements at a distance from the Digibridge. 1.4 ACCESSORIES. Gen Rad makes several accessories that enhance the use 1.2 GENERAL DESCRIPTION.fulness of this instrume
16、nt. Two extender cables facilitate Convenience is enhanced by the arrangement of testmaking connections to those devices and impedance stan fixture on the front ledge, with push buttons farther for-dards that do not readily fit the built-in test fixture. A ward and display behind. The display panel
17、is inclined and remote test fixture (used with BNC adaptor and cable recessed to enhance visbility of digital readouts and modeassembly) provides convenience and relatively easy main indicators. These indicators serve to inform and guide the tenance, and saves wear on the built-in test fixture. All
18、of operator as he operates the simple controls. these test-fixture accessories provide for true 4-terminal The instrument stands on a table or bench top. Theconnections (and guard) to the device being measured, sturdy metal cabinet is attractively and durably finished,without appreciable reduction i
19、n measurement accuracy. Other useful accessories are offered, such as standards for checking the performance of the Digibridge. Refer to Table 1 -3 and Section 5. INTRODUCTION 1-1 1-2 INTRODUCTION INTRODUCTION 1-3 1-4 INTRODUCTION 2.1 UNPACKING AND INSPECTION. If the shipping carton is damaged, ask
20、that the carriers agent be present when the instrument is unpacked. Inspect the instrument for damage (scratches, dents, broken parts, etc.). If the instrument is damaged or fails to meet specifications, notify the carrier and the nearest GenRad field office. (See list at back of this manual). Retai
21、n the shipping carton and the padding material for the carriers inspection. 2.2 DIMENSIONS Figure 2-1. The instrument is supplied in the bench configuration, i.e., in a cabinet with resilient feet for placement on a table. The overall dimensions are given in the figure. 2.3 POWER-liNE CONNECTION. Th
22、e power transformer primary windings can be switched, by means of the line voltage switch on the rear panel, to ac. commodate ac line voltages in either of 2 ranges, as labeled, at a frequency of 50 or 60 Hz, nominal. Using a small screwdriver, set this switch to match the measured voltage of your p
23、ower line. I f your I ine voltage is in the lower range, connect the 3-wire power cable (P/N 4200-9625) to the power connector on the rear panel (Figure 1-2) and then to the power line. The instrument is fitted with a power connector that is in conformance with the International Electrotechnical Com
24、mission publication 320. The 3 flat contacts are surrounded by a cylindrical plastic shroud that reduces the possibility of electrical shock whenever the power cord is being unplugged from the instrument. In addition, the center ground pin is longer, which means that it mates first and disconnects l