DE_5000_im 电路图.pdf
《DE_5000_im 电路图.pdf》由会员分享,可在线阅读,更多相关《DE_5000_im 电路图.pdf(52页珍藏版)》请在收音机爱好者资料库上搜索。
1、 PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 534 Main Street, Westbury, NY 11590 IET LABS, INC. DE-5000 Portable, Full-Featured LCR Meter User and Service Manual RadioFans.CN 收音机爱 好者资料库 TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 5
2、34 Main Street, Westbury, NY 11590 IET LABS, INC. RadioFans.CN 收音机爱 好者资料库 PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 534 Main Street, Westbury, NY 11590 IET LABS, INC. Copyright 2011 IET Labs, Inc. Visit for manual revision updates DE-5000 i
3、m/October 2011 DE-5000 Portable, Full-Featured LCR Meter User and Service Manual RadioFans.CN 收音机爱 好者资料库 PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 534 Main Street, Westbury, NY 11590 IET LABS, INC. WARRANTY We warrant that this product is f
4、ree from defects in material and workmanship and, when properly used, will perform in accordance with applicable IET specifi cations. If within one year after original shipment, it is found not to meet this standard, it will be repaired or, at the option of IET, replaced at no charge when returned t
5、o IET. Changes in this product not approved by IET or application of voltages or currents greater than those allowed by the specifi cations shall void this warranty. IET shall not be liable for any indirect, special, or consequential damages, even if notice has been given to the possibility of such
6、damages. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. WARNING OBSERVE ALL SAFETY RULES WHEN WORKING WITH HIGH VOLTAGES OR LINE VOLTAGES. Dangerous voltages may be p
7、resent inside this instrument. Do not open the case Refer servicing to qualifi ed personnel HIGH VOLTAGES MAY BE PRESENT AT THE TERMINALS OF THIS INSTRUMENT WHENEVER HAZARDOUS VOLTAGES ( 45 V) ARE USED, TAKE ALL MEASURES TO AVOID ACCIDENTAL CONTACT WITH ANY LIVE COMPONENTS. USE MAXIMUM INSULATION AN
8、D MINIMIZE THE USE OF BARE CONDUCTORS WHEN USING THIS INSTRUMENT. Use extreme caution when working with bare conductors or bus bars. WHEN WORKING WITH HIGH VOLTAGES, POST WARNING SIGNS AND KEEP UNREQUIRED PERSONNEL SAFELY AWAY. CAUTION DO NOT APPLY ANY VOLTAGES OR CURRENTS TO THE TERMINALS OF THIS I
9、NSTRUMENT IN EXCESS OF THE MAXIMUM LIMITS INDICATED ON THE FRONT PANEL OR THE OPERATING GUIDE LABEL. - iii - Table of Contents Chapter 1: Introduction . 1 1.1. Overview .1 1.2. Introduction to measuring principles .2 1.2.1. What is impedance . 2 1.2.2. Measuring impedance . 4 1.3. Equivalent circuit
10、 .6 1.4. Instrument layout .7 1.5. LCD display layout . 10 Chapter 2: Operation . 12 2.1. How to obtain optimum precision . 12 2.2. Default settings . 12 2.3. Zeroing the meter . 14 2.4. Attaching DUTs to the meter . 17 2.5. Primary measurements and functions . 19 2.5.1. Measuring inductance, capaci
11、tance, and resistance . 19 2.5.2. Measuring dissipation, quality, ESR, and phase angle. 22 2.5.3. Sorting components . 24 2.5.4. Making relative measurements . 26 2.6. Additional settings . 30 2.6.1. Selecting test frequency . 30 2.6.2. Making measurements in series and parallel . 32 - iv - 2.7. Add
12、itional features . 33 2.7.1. Connecting to a PC . 33 2.7.2. Using the backlight . 35 2.7.3. Holding a reading on the display . 35 2.8. Replacing Batteries . 36 Chapter 3: Specifications . 37 3.1. General specifications . 37 3.2. Accuracy specifications . 39 3.3. Ordering information . 42 - 1 - Chapt
13、er 1: Introduction 1.1. Overview The DE-500 is a portable, high-performance LCR meter that is full-featured yet cost effective. It measures in true 4-wire Kelvin mode and rivals the capabilities and options of many of its bench counterparts. It measures: Ls/Lp - Series and parallel inductance Cs/Cp
14、- Series and parallel capacitance Rs/Rp - Series and parallel resistance (ac) Rdc/Rp - Series and parallel resistance (dc) ESR/Rp - Series and parallel equivalent resistance D - Dissipation factor Q - Quality factor - Phase angle This LCR meter can transfer data to a PC via a standard, fully isolate
15、d, optical IR-USB interface. It also features a Sorting mode, allowing users to quickly sort components. DE-5000 has automatic LCR selection. This allows the user to measure the L/C/R components in Auto LCR mode without having to select the type of measurement. - 2 - To accommodate various test requ
16、irements, the DE-5000 offers selectable test frequencies: 100 Hz / 120 Hz / 1 kHz / 10 kHz / 100 kHz. The unit is powered by a standard 9V battery. For additional convenience, it may also use an optional ac adapter (DE-5000-AC). To transfer data to a PC, the unit comes with a built-in IR interface.
17、IET offers an optional Data Transfer Kit (DE-5000-DTK). This kit includes: IR-USB interface adapter, a USB cable, and a CD with software for the PC. 1.2. Introduction to measuring principles 1.2.1. What is impedance Impedance (Z) consists of resistance (real part) and reactance (imaginary part). Ser
18、ies impedance (Zs) can be defined as a combination of series resistance (Rs) and series reactance (Xs). It can be represented mathematically as magnitude |Z|=(Rs2+Xs2) at a phase angle . - 3 - There are two types of reactance. One is inductive reactance XL, and the other is capacitive reactance XC.
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DE_5000_im 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


