1、054001 OUTPUT UNIT Instruction Manual -GOULDADVANCE Telephone 01-5001000 Telegrams AttenuateIlford Telex 263785 RadioFans.CN 收音机爱 好者资料库 SECTION1Introduction3 SECTION5Maintenance12 5.1Fitting the 4001 to the OS400012 SECTION2Specification4 5.2Access13 5.3Fault finding14 SECTION3Operating Instructions
2、5 5.4Setting up Procedure15 3.1General5 3.2Chart recorder speed5 SECTION6Circuit Diagrams and Components 3.3Driving a chart recorder5 Schedules17 3.4The Read-out cycle5 3.5Remote start5SECTION7 Guarantee and Service Facilities21 3.6Function Generation7 3.7Digital Outputs7 ILLUSTRATIONS Fig. 1Typical
3、 read-out cycle6 SECTION4Circuit Description8 Fig. 2Connectionsto back panel socket 7 4.1General8 Fig. 3Block diagram8 4.2D-A Converter9 Fig. 4Data Selector - mechanical 4.3Latches and latch control9 equivalent10 4.4 X-ramp counter9 Fig. 5Clock delay - timing diagram 11 4.5Data Selector9 Fig. 6Inter
4、nal view of 4001 12 4.6Clock delay10 Fig. 7Fixing details 13 Fig. 8Circuit diagram 19 RadioFans.CN 收音机爱 好者资料库 Introduction The 400 I option is designed to be added to a standard OS4000 Digital Storage Oscilloscope to enable the infor- mation in store to be retransmittedin both analogue and digital f
5、orm.Two analogue outputs are provided, and these are intended primarily to drive strip chart and X-V recorders.Channel I and 2 signals are available simultan- eously at a read-out rate which can be varied to suit the chart recorder, with a slowest time of 200 seconds representing the 10 division dis
6、play.In addition, a correspondingX-ramp signal is provided for X-Y recorder use. The unit also incorporatesrelay contacts for pen lift or chart motor control.There is a variable delay between the closing of these contacts and the start of read out which can be preset to allow a chart drive motor to
7、accelerate. .A socket on the rear panel presents the outputinfor- mation in digital form as two eight bit parallel signals for Y and one ten bit parallel signal for the X ramp.Control facilities for remote start and continuousreadout are also provided.The latter can be used for continuous generation
8、 of a recorded transient or frequencyshift of recorded waveforms. RadioFans.CN 收音机爱 好者资料库 Specification ANALOGUEOUTPUTSVia B.N.C. connectors Channels 1 and 2 AmplitudelOOmV per cm of screen height. Bipolar with OV correspondingto middle of screen AccuracyOutput voltage per cm of display3% Output to
9、input voltage (ca!)3% X Ramp Amplitude lOOmV per cm of screen width. Positive ramp resetting to OV Output voltage/cm of displayJ% Output voltage/unittime recorded3% Time outputaccuracy of Y Channel outputs1% (Record to replay ratio) Output ImpedanceCHI, CH2 and X-ramp100H/0.IJ.lF Continuousshort cir
10、cuit protected DIGITALOUTPUTSVia back panel socket All outputstrue binary from open collector T.T.L. buffers 8 bit parallel, negative logic 10 bit parallel, negative logic Y Channelfull scale=9cm of display5% X Rampfull scale=II.3cmof display 5% Channels I and 2 X Ramp Accuracy READ OUT RATE Set on
11、OS4000 time base range switch Range 20sec/cm to200J.ls/cm Read-out bandwidthD.C. -16kHz (-3dB) CONTROLS Front panel start buttonto initiate single read-out cycle. Remote start by T.T.L.lowor contact closure to ground. Section 2 Remote continuousread-out by T.T.L. low or contact closure to ground. De
12、lay between start command and initiation of read-out cycle set by front panel preset control fromI sec. (lOJ.lsec. to lOsec. by internal component change) Front panel access via 4mm sockets to isolated single pole contact which closes from start command to end of read-out cycle Contact rating 200V D
13、.C. 0.5 A D.C. IOWD.C. Isolation 400V max. OUTPUTS Oocks I and 2 Negative T.T.L. pulses, 100nsec. duration marking the change of each digital word. T.T.L. low, commencingat the end of delay, for the durationof the read-out cycle. DIMENSIONS3.75cm extra height to OS4000 WEIGHT570gm extra (l%Ib) to OS
14、4000 approx. ACCESSORIES36 way plugAmpheno157-30360 2 x 4mm plugs Handbook PN 36896 Operation 3.1ANALOGUEOUTPUTS The 4001 may be used to drive strip-chart, T-Y or X-V recorders.Both Y channels are available simultaneously for chart recorders with two pens. Alternatively,the two channels may be repro
15、ducedsequentially on single pen recorders.A synchronisedX-ramp is available to drive X-V recorders as Y-t. Alternatively,the CHI and CH2 outputs can drive an X-Y display directly. The internal contacts can be used to control chart motor and/or pen lift if required. 3.2CHARTRECORDERSPEED The 4001 off
16、ers a very wide range of read-out rates to suit the recorder being used. The rate should be chosen by considering the following: 1)A slow read-out rate, while faithfully reproducing the stored signal, will also show the discrete levels in the output waveform, (there is no dot-joining on the 4001 out
17、puts).A faster read-out rate and chart recorder speed will tend to smooth the output wave form. 2)If too high a read-out rate is chosen, the chart recorder may be unable to follow any large ampli- tude fast change of the signal. This is slew-rate limitation of the recorder. The optimum read out spee
18、d for any particular stored waveform is thus the maximum at which the chart recorder is capable of tracking the signal. This may be determinedby increasing the readout/chart recorder speed each sweep until waveform degrad- ation can be observed. The bandwidth of the outputamplifier is d.c. to 16kHz
19、(-3d B) which is well above the limitationof most chart recorders.However this limitationmay be reached if the outputis required for other purposes when the replay frequencyis a function of recorded waveform and replay rate. (See Function Generator) 3.3DRIVINGA CHARTRECORDER 1)Connect to the CHI, CH
20、2 and X-ramp sockets as reqUired. In single trace operation,the same signal will be present at CHI and CH2 outputs. Set the sensitivity of the chart recorder inputs to accommodate400rn V f.s. on CHI and CH2 and oto 1V on the X-ramp. When the 4001 is not reading out, the CHI and 2 and the X-ramp outp
21、uts return toOV.Ov on the V-channel outputcorrespondsto mid-screen on the OS4000 display and thus the chart recorder pen should be set to mid-scale unless specifically required otherwise. The X-ramp moves positive fromOVand thus the pen should be positionedto allow at least 1V positive travel. 2)Con
22、nect, if required for remote start/penlift. NOTE:The relay contacts are unprotectedand inductive loads should be suppressed to stay within the contact rating. 3)The delay time (from closing of relay contacts to start of read-out) is set by a front panel screwdriver preset.The minimum delay time of20
23、rns is sufficiently short for recorders for which no delay is required.The preset control range allows the delay time to be set to a maximum of 1 second but this can be increased to approx.10 sec. by increasing the internal capacitor C80I to I5tlF. 4)Obtain the required trace on the OS4000 and STORE
24、 or LOCK it. If the 50% hold facility is being used, the trace stored by the 50% hold will appear at the CH2 output,the other trace appearing at CHI. 5)Set the required read-out rate on the timebase range switch. 6)Press the start switch to initiate the read-out cycle. Note the display is inhibited