1689_im 电路图.pdf
《1689_im 电路图.pdf》由会员分享,可在线阅读,更多相关《1689_im 电路图.pdf(211页珍藏版)》请在收音机爱好者资料库上搜索。
1、1689/1689M SERIES Precision RLC Digibridge User and Service Manual PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT Copyright 2006 IET Labs, Inc. 1689/December 2006 TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 IET LABS, INC. formerly manufacturer by GenRad 534 Main Street, Westbury, NY 11590
2、 RadioFans.CN 收音机爱 好者资料库 PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 534 Main Street, Westbury, NY 11590 IET LABS, INC. RadioFans.CN 收音机爱 好者资料库 iii WARRANTY We warrant that this product is free from defects in material and workmanship and, wh
3、en properly used, will perform in accordance with applicable IET specifications. If within one year after original shipment, it is found not to meet this standard, it will be repaired or, at the option of IET, replaced at no charge when returned to IET. Changes in this product not approved by IET or
4、 application of voltages or currents greater than those allowed by the specifications shall void this warranty. IET shall not be liable for any indirect, special, or consequential damages, even if notice has been given to the possibility of such damages. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANT
5、IES, EXPRESSED OR IMPLIED, INCLUD- ING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTIBILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. RadioFans.CN 收音机爱 好者资料库 vii WARNING OBSERVE ALL SAFETY RULES WHEN WORKING WITH HIGH VOLTAGES OR LINE VOLTAGES. Dangerous voltages may be present inside this instr
6、ument. Do not open the case Refer servicing to qulified personnel HIGH VOLTAGES MAY BE PRESENT AT THE TERMINALS OF THIS INSTRUMENT WHENEVER HAZARDOUS VOLTAGES ( 45 V) ARE USED, TAKE ALL MEASURES TO AVOID ACCIDENTAL CONTACT WITH ANY LIVE COMPONENTS. USE MAXIMUM INSULATION AND MINIMIZE THE USE OF BARE
7、 CONDUCTORS WHEN USING THIS INSTRUMENT. Use extreme caution when working with bare conductors or bus bars. WHEN WORKING WITH HIGH VOLTAGES, POST WARNING SIGNS AND KEEP UNREQUIRED PERSONNEL SAFELY AWAY. CAUTION DO NOT APPLY ANY VOLTAGES OR CURRENTS TO THE TERMINALS OF THIS INSTRUMENT IN EXCESS OF THE
8、 MAXIMUM LIMITS INDICATED ON THE FRONT PANEL OR THE OPERATING GUIDE LABEL. 700011. Instruction Manual Changes (continued) Page 5-41 -Table 5-7, Capacitance Accuracy Checks .QDR Display Max column corrected as follows: Nominal Value QDR Max 10 pF6100 ppm 100 pF2500 ppm 1500 pF700 ppm 1500 pF1000 ppm
9、1500 pF1700 ppm 6400 pF500 ppm 10 nF500 ppm 25 nF500 ppm 25 nF800 ppm 25 nF1500 ppm 100 nF500 ppm 200 nF600 ppm 400 nF600 ppm 400 nF900 ppm 400 nF1600 ppm 1000 nF600 ppm Page 6-2 -Figure 6-2, 1689 Rear View Rear view should show new power supply assembly (PN 700011) without line voltage switch. Page
10、 6-3 -Mechanical Parts List for 1689, Rear Items 4 through 7 (power connector, fuse extractor post and line voltage switch and cover) deleted on new power supply assembly. Page 6-4 -Figure 6-2(A), 1689M Rear View Rear view should show new power supply assembly (pN 700011) without line voltage switch
11、. Page 6-5 -Mechanical Parts List for 1689M, Rear Items 3 through 6 (power connector, fuse extractor post, line voltage switch and cover) deleted on new power supply assembly. Page 6-15 RLC difference: same as R, L, or C. If any of these quantities is negative, the NEG RLC indicator light is lit. vi
12、i TABLE A GR1689 MEASUREMENT RATE TEST FREQUENCY MEASUREMENT RATE 12 Hz 100 Hz 120Hz 1 kHz 10 kHz 100 kHz SLOW 875 ms 940 ms 940 ms 970 ms 930 ms 930 ms MEDIUM 670 ms 130 ms 185 ms 200 ms 190 ms 190 ms FAST 670 ms 125 ms 110 ms 80 ms 75 ms 70 ms MAX IMUM 670 ms 110 ms* 100 ms* 40 ms 34 ms 33 ms Note
13、s:1. If the high-speed option is not used, add 19 ms for MAXIMUM, or 38 ms for SLOW, NEDIUM or FAST measurement. 2. If the display is value, delta%, or deltaRLC, add 6 to 10 ms. 3. If data is output via the IEEE Bus., add 6 to 12 ms. 4. For ACQ, subtract 22 ms for SLOW, MEDIUM or FAST and 12 ms for
14、MAXIMUM. TABLE B GR1689M MEASUREMENT RATE TEST FREQUENCY MEASUREMENT RATE12 Hz100 Hz120 Hz1 kHz10 kHz100 kHz SLOW 875 ms 920 ms 920 ms 950 ms 920 ms 920 ms MEDIUM 670 ms 120 ms 170 ms 180 ms 170 ms 170 ms FAST670 ms105 ms90 ms65 ms55 ms55 ms MAXIMUM 660 ms 101 ms* 86 ms* 32 ms 22 ms 22 ms Notes: 1.
15、If the high-speed option is not used, add 12 ms for MAXIMUM, or 24 ms for SLOW, MEDIUM or FAST measurement. 2. If the display is value, delta% or deltaRLC, add 3 to 5 ms. 3. If data is output via the IEEE Bus, add 3 to 6 ms. 4. For ACQ, subtract 11 ms for SLOW, MEDIUM or FAST and 6 ms for MAXIMUM. *
16、 These times can be shortened by 14 ms with reduced accuracy using the quick acquisition routine. The measurement times are obtained with use of the high-speed measurement option, continuous measurement mode, bin number display/handler output, and without IEEE-Bus data output. For other conditions,
17、refer to the table notes. If the measurement mode is triggered, programmed delay (settling time), if any, should be added. Normal power up conditions included a programmed delay of 7/f to 12/f ms depending upon measurement rate. This delay can be programmed to zero or to any value up to 100 sec. Tes
18、t connections can be broken (handler indexing can begin) as soon as data acquisition is complete (ACQ line low on handler interface). See Note 4 in tables. i x Measurement Modes Two test modes are available: CONTINUOUS and TRIGGERED. The CONTINUOUS mode makes successive measurements continuously, up
19、dating the display after each measurement. TRIGGERED measurements are initiated by the START button, or remotely from the IEEE bus or from the Handler Interface, and the measurement result is displayed until the next measurement is started. Average The AVERAGE of any number of measurements from 1 to
20、 255 may be made as desired in either of the two MEASURE MODES. In the TRIGGERED mode, the running average is displayed and the final value held until the START button is again depressed. In the CONTINUOUS mode, only the final value is displayed. Test Voltage The RMS test voltage is selectable from
21、5 mV to 1.275 V in 5 mV steps. The accuracy is: (5% + 2 mV) (1 + .001 f 2) where f = frequency in kHz. This voltage may be applied behind a source impedance (which depends on the range) in which case the selected voltage is the maximum that will be applied and the voltage will be less at the low imp
22、edance end of each range. The voltage may be applied also behind 25 ohms using the CONSTANT VOLTAGE function in which case the applied voltage will be constant except when low impedances are measured. Delay A delay of from 1 to 99999 ms may be added to allow for settling of external switches and to
23、permit a wider selection of measurement rates. DC Bias An internal bias of 2 V may be applied to capacitors under test by means of the INT BIAS key. An external bias of up to 60 VDC may be applied to capacitors under test using a panel switch. The applied current should be limited to 200 mA. The ins
24、trument is protected from damage from charged capacitors with a stored energy up to 1 joule at 60 volts or less. Protection from higher voltages may be provided by external components. Zeroing Open: A simple OPEN operation removes the effects of stray capacitance and conductance of the internal test