1、Giga-tronics Incorporated v 4650 Norris Canyon Road v San Ramon, California 94583 925.328.4650 or 800.726.4442 v 925.328.4700 (Fax) v 800.444.2878 (Customer Service) v 925.328.4702 (CS Fax) ISO 9001. Certified Process Registrar: BSI, Certification No. FM 34226 v Registered 04 June 1996 v Amended 01
2、March 2000 P/N: Revision: Publication Date: 58542 VXIbus Universal Power Meter Operation address 255 permits the Resource Manager to dynamically address the unit based on the chassis VXI slot. To change the logical address, set the respective sections on the eight position DIP switch. The switch is
3、accessible after removing the right cover (see Figure 2-1). The address is set with binary values of 0 to 255. Switch position 1 is the least significant bit of the address. Figure 2-1 illustrates logical address values of 3 (binary 00000011) and 255 (binary 11111111). Giga-tronics ships the power m
4、eter with a logical address of 255 for dynamic configuration. Figure 2-1: Setting the Logical Address RIGHT SIDE HOUSING COVER 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 LOGICAL ADDRESS:LOGICAL ADDRESS: 2553 8-POSITION DIP SWITCH Operation Publication 21555, Rev. F, March 20072-3 2.3.2Data Transfer Bus Arbitra
5、tion The power meter has VMEbus Mastership capability. When enabled, it sends responses and events as signals (software interrupts) to its Commander Signal Register. The power meter cannot drive the interrupt lines. The power meter is configured as a level 3 requester by the factory. The level 3 Bus
6、 Request and Bus Grant lines (BR3*, BG3IN* and BG3OUT*) are used. The other Bus Grant lines are daisy-chained by jumpers (see Figure 2-2). The VMEbus specifications describe three priority schemes: (1) Prioritized, (2) round-robin, and (3) single level. Prioritized arbitration assigns the bus accord
7、ing to a fixed priority scheme where each of four bus lines has a priority from highest (BR3*) to lowest (BR0*). Round-robin arbitration assigns the bus on a rotating basis. Single level arbitration accepts requests only on BR3*. The jumpers must be changed if a different requester level is required
8、. Figure 2-2 will aid in reconfiguring the power meter to a new level. Refer to the VMEbus specification for more information on data transfer bus arbitration. Figure 2-2: Default Bus Arbitration Settings 13 1213 1213 1213 12 24 124 124 124 1 BR0 BG0IN BG0OUT BR1 BG1IN BG1OUT BR2 BG2IN BG2OUT BR3 BG
9、3IN BG3OUT 0 123 FACTORY SETTING ARBITRATION LEVEL BUS REQUEST ARBITRATION LEVEL JUMPER BLOCK RIGHT SIDE HOUSING COVER 58542 VXIbus Universal Power Meter 2-4Publication 21555, Rev. F, March 2007 2.4Sensor Precautions Sensors used with the 58542 are configured in metal housings for superior mechanica
10、l performance as well as excellent shielding. When connecting the sensors to other devices or components, the body of the sensor should never be turned to tighten the RF connection. Mechanical damage to the connector can result if im- properly handled when connecting the sensors. Scratched or damage
11、d connector mating surfaces can lead to inaccurate mea- surements. If a sensor is connected to CW or peak power devices with power output in excess of +23 dBm (200 mW), degradation or destruc- tion of the diode can occur. Diodes degraded or destroyed in this manner will not be replaced under warrant
12、y. Destructive signal levels are higher for High Power, TrueRMS, and Low VSWR sensors. 2.5Operation 2.5.1SCPI Command Interface This section details operation of the power meter using the SCPI interface commands. A SCPI Command Reference is presented in Table 2-2 and the sections that follow. The po
13、wer meter is compatible with the Standard Commands for Programmable Instruments (SCPI) standard. SCPI promotes consistency in its definition of a common instrument control and measurement command language. The structured approach of the SCPI standard offers test system design engineers a number of s
14、ystem integration advantages that achieve considerable efficiency gains during control program development. SCPI compatible instrument commands are structured from a common functional organization or model of a test instrument (see Figure 2-3). Most of the power meter configuration and measurement f
15、unctions fall within the Measurement Function Block and the Trigger Subsystem of the SCPI instrument model. The 58542 uses the SENSe Subsystem of the Measurement Function Block to implement commands that apply specifically to the individual power sensors; sensor 1, and sensor 2. For example, the SEN
16、Se2:CORRection:OFFSet command corrects for the attenuation of a signal that passes through an attenuator or coupler before it is measured by power sensor 2. Figure 2-3 illustrates the SCPI subsystem model. NOTE: Throughout this manual, some commands will be in both upper and lowercase, such as CALCu
17、late and MEMory. The uppercase is the required input. The whole word can be used if desired. CAUTION * Operation Publication 21555, Rev. F, March 20072-5 Figure 2-3: SCPI Subsystem Model SENSeCALCulate TRIGgerMEMory 58542 VXIbus Universal Power Meter 2-6Publication 21555, Rev. F, March 2007 2.5.2Sen
18、sor and Channel Configuration The CALCulate Subsystem of the Measurement Function Block contains commands that define the form of the measured data from sensor 1 and sensor 2. CALCulate commands define the configuration of the two Software Calculation Channels (channels). For example, the CALC1:POW
19、1 command configures channel 1 to report the power level as measured by sensor 1. CALC2: RAT 2,1 configures channel 2 to report the ratio of power levels, sensor 2 over sensor 1. 2.5.3Measurement TRIGgering The power meter uses the TRIGger Subsystem to trigger measurements in two different operation
20、al modes - a normal mode which maximizes the instruments functionality, and swift and burst modes that maximize the power measurement rate. 2.5.4MEMory Functions The MEMory commands control the configuration of the automated Voltage-Proportional-to-Frequency (VPROPF), sensor Cal Factor correction, a
21、nd the Analog Output on the front panel. Each of these connectors is used with external devices. The VPROPF can be configured to match the VPROPF output of your microwave source. The Analog Output is used with a variety of devices including chart recorders, oscilloscopes, voltmeters, and microwave s
22、ource leveling inputs. 2.5.5IEEE 488.2 Commands Consistent with SCPI compliance criteria, the power meter implements all the common commands declared mandatory by IEEE 488.2. These commands are listed in Table 2-1. 2.5.6DIAGnostic Commands DIAGnostic commands are used for a variety of instrument spe
23、cific maintenance and calibration functions. Unless you are performing instrument calibration functions, it is unlikely that you will need to use the DIAGnostic command sets. For calibration laboratory metrology professionals, the DIAG commands will allow you to completely automate instrument and se
24、nsor calibration functions. The commands program EEPROMs inside the meter and individual sensors. If desired, a password function Table 2-1: VXI GPIB Command Syntax MnemonicName *CLSClear Status Command *ESEStandard Event Status Enable Command *ESE?Standard Event Status Enable Query *ESR?Standard Ev