1、1 Introduction HATS-Y Series Chapter 1 INTRODUCTION and nominal) for all three decades is essentially the same, e.g. if the adjustment error at 100 k is 4 ppm, then it is also 4 ppm at 10 k and 1 M, remember- ing that the transfer accuracy error has to be added at these additional decade settings. T
2、he HATS-Y standards are constructed using matched low temperature coefficient, hermetically sealed resistors (except for 10 and 100 M step units) for high stability and imperviousness to moisture. Each resistance step is composed of multiple individual re- sistors for better power handling, heat dis
3、tribution, and higher voltage capability. In addition, there is a trim- ming network that allows precise setting of the resis- tance step values, and greatly simplifies subsequent calibrations. The switches are of special low-leakage construc- tion. Switches are placed at every junction and at the t
4、wo ends of the series string to connect that junction to either of the two binding posts; a center-off setting provides for no connection to that junction. By means of these switches, the resistances may be connected in various series-parallel combinations. Low-thermal-emf five way binding posts are
5、 used for connections to the two buses, and a shielded bnc con- nector provides for connection to one end of the re- sistor string. A third, metal, binding post provides a connection to the metal case; this may be used as a guard. The unit is housed in a contamination-and-moisture- resistant case Th
6、e insulation materials in the instru- ment are Kel-F plastic and teflon, for the highest pos- sible resistance and low moisture absorption. 1.1 General Description The HATS-Y Series (Figure 1.1) is a family of trans- fer standards suitable for making resistance calibra- tion transfer measurements fr
7、om 10 k to 1 G, with step sizes ranging from 100 k to 100 M In order to perform calibrations with a high degree of accuracy, reference standards must normally be em- ployed at every range or decade of the measuring or calibration instrumentation. Clearly this can be diffi- cult and costly, since the
8、se standards must be highly stable and their values must be known with a high degree of certainty and with a sufficient resolution. To minimize the cost and difficulty, a more practical means of performing such calibrations is to use trans- fer standards. The HATS-Y Series of transfer standard consi
9、sts of 11 matched equal value resistors, R, which may be connected in series or parallel combinations to pro- duce a number of values such as R/10, R, and 10R, thereby allowing progressive transfers to higher or lower decades. For lower resistance values (below 10 k) The HATS-LR Series of transfer s
10、tandards may by used. If one has a single primary standard with a traceable calibration, one can calibrate the transfer standard to the primary standard. The transfer standard may then be used at R/10, R, and at 10R, where R is the step size. It may be used at these three decades with an uncertainty
11、 that is equal to the initial calibration un- certainty of the steps plus the transfer uncertainty. For example, if a 100 k step HATS-Y unit has a nominal uncertainty of 5 ppm and a transfer uncer- tainty of 2 ppm, then it may be used at 10 k and 1 M with an uncertainty of 7 ppm. The nominal ad- jus
12、tment error (the difference between actual value RadioFans.CN 收音机爱 好者资料库 2 Specifications HATS-Y Series Chapter 2 SPECIFICATIONS For convenience to the user, the pertinent specifica- tions are given in an OPERATING GUIDE, Figure 2.1, affixed to the unit. A calibration chart, as shown in Figure 2.2,
13、is also affixed to the side of the unit. This gives the indi- vidual and progressive cumulative deviations from nominal. These are deviations which may be used for transfers. Specifications: Calibration Conditions: 23C, with meter guard applied to COM and ground applied to the center metal post, at
14、low power, traceable to SI. Initial cali- bration data is supplied with each instrument. Leakage Resistance: 10 T from terminal to case. Power Coefficient: 0.05 ppm/mW per resistor. Resistor Type: Matched low temperature coeffi- cient, hermetically sealed resistors, or high voltage film resistors fo
15、r 10 M and 100 M steps. In addi- tion, there is a lockable trimming potentiometer that Step Size100 k1 M10 M100 M Adjustment Accuracy 10 ppm 20 ppm 20 ppm 100 ppm Transfer Accuracy 2 ppm2 ppm2 ppm30 ppm Stability ppm/year 10 ppm 15 ppm 30 ppm 30 ppm Stability long term 30 ppm 30 ppm 50 ppm 50 ppm Te
16、mperature Coefficient 1 ppm/oC3 ppm/oC5 ppm/oC5 ppm/oC Matching Adj. Acc. 10 ppm 10 ppm 10 ppm 20 ppm TC 1 ppm3 ppm3 ppm5 ppm Calibration Uncertainty 5 ppm10 ppm 10 ppm 15 ppm allows precise setting of the resistance step values, and greatly simplifies subsequent calibrations. Switches: The switches
17、 are of special low-leakage construction. The switches are tied to every junction and at the two ends of the series string to connect that junction to either of the two binding posts; a cen- ter-off setting provides for no connection to that junc- tion. By means of these switches, the resistances ma
18、y be connected in various series-parallel combinations Terminals: Two low-thermal-emf five way binding posts; a shielded bnc connector provides for connec- tion to one end of the resistor string. A third metal binding post provides for connection to the metal case; this may be used as a guard. Dimen
19、sions: 35.6 cm W x 16.5 cm H x 10.2 cm D (14 x 6.5 x 4). Weight: 5 kg (11 lb.). Functional Schematic: RadioFans.CN 收音机爱 好者资料库 3 Specifications HATS-Y Series MODEL: HATS-Y-100M SN: E1-0536109 Transfer Accuracy: Limited only by short term repeatability of resistance values. Calibration Conditions: 23C
20、, with meter guard applied to COM and ground applied to G, at low power, traceable to SI. Calibration data supplied with instrument. Power Coefficient: 10 T from terminal to case. Operation: (With switch 0 being leftmost). To set standard to R/10, set Switch 0 down, Switch 1 up, switch 2 down and so
21、 on; Switch 11 off. To set standard to 10R, set Switch 0 down, Switch 10 up, all other switches off. HATS-Y OPERATING GUIDE To set standard to 1R, set Switches 0 and 6 down, Switches 3 and 9 up, all other switches off. Functional Schematic: IET LABS, INC.IET LABS, INC.IET LABS, INC.IET LABS, INC.IET
22、 LABS, INC. Westbury, NY 11590 (516) 334-5959 (800) 899-8438 HATS-YLBL (PPM style)/ 4-4-06 Step Size100 k1 M10 M100 M Adjustment Accuracy 10 ppm 20 ppm 20 ppm 100 ppm Transfer Accuracy 2 ppm2 ppm2 ppm30 ppm Stability ppm/year 10 ppm 15 ppm 20 ppm 30 ppm Stability long term 30 ppm 30 ppm 30 ppm 50 pp
23、m Temperature Coefficient 1 ppm/oC 3 ppm/oC 5 ppm/oC 5 ppm/oC Matching Adj. Acc. 10 ppm 10 ppm 10 ppm 20 ppm TC 1 ppm3 ppm3 ppm5 ppm Calibration Uncertainty 5 ppm10 ppm 10 ppm 15 ppm Figure 2.1. Typical OPERATING GUIDE Affixed to Unit Figure 2.2. Typical Calibration Chart, providing deviations, Affi
24、xed to Unit CALIBRATION CHART Deviations from 10 M Nominal Traceable to SI Temperature: 23.1C Date: 29 Mar 2006 Date Due: 29 Mar 2007 Model: HATS-Y-10M Serial Number: E1-0536108 BY: JOS 516-334-5959 (FAX) 516-334-5988 IET LABS, INC.IET LABS, INC.IET LABS, INC.IET LABS, INC.IET LABS, INC.Westbury, NY
- 配套讲稿: