8540C 电路图.pdf
《8540C 电路图.pdf》由会员分享,可在线阅读,更多相关《8540C 电路图.pdf(265页珍藏版)》请在收音机爱好者资料库上搜索。
1、. Certified Product ISO 9001.Certified Process Registrar: BSI, Certification No. FM 34226 Registered 04 June 1996 Amended on 01 March 2000 Giga-tronics Incorporated 4650 Norris Canyon Road San Ramon, California 94583 925.328.4650 or 800.726.4442 925.328.4700 (Fax) 800.444.2878 (Customer Service) 925
2、.328.4702 (Fax) Manual Part Number: Revision: Print Date: Operation see Appendix B for Power Sensor Specifications. 1.1.8Tools and Test Equipment No special tools are required to operate the 8540C. Test equipment required for calibration or performance verification is described in Chapter 4. 1.1.9Co
3、oling No cooling is required if the instrument is operated within its specified operating temperature range (0 to 50 C). Introduction Manual 30280, Rev. J, September 20001-3 1.1.10Cleaning The front panel can be cleaned using a cloth dampened with a mild detergent; wipe off the detergent residue wit
4、h a damp cloth and dry with a dry cloth. Solvents and abrasive cleaners should not be used. 1.1.11Installation and Preparation for Use The instrument is shipped in an operational condition and no special installation procedures are required. 1.1.12Receiving Inspection Use care in removing the instru
5、ment from the carton and check immediately for physical damage, such as bent or broken connectors on the front and rear panels, dents or scratches on the panels, broken extractor handles, etc. Check the shipping carton for evidence of physical damage and immediately report any damage to the shipping
6、 carrier. Each Giga-tronics instrument must pass rigorous inspections and tests prior to shipment. Upon receipt, its performance should be verified to ensure that operation has not been impaired during shipment. The performance verification procedure is described in Chapter 5 of this manual. 1.1.13P
7、reparation for Reshipment Follow these instructions if it is necessary to return the product to the factory. To protect the instrument during reshipment, use the best packaging materials available. If possible use the original shipping container. If this is not possible, a strong carton or a wooden
8、box should be used Wrap the instrument in heavy paper or plastic before placing it in the shipping container. Completely fill the areas on all sides of the instrument with packaging material. Take extra precautions to protect the front and rear panels. Seal the package with strong tape or metal band
9、s. Mark the outside of the package “FRAGILE FRAGILE FRAGILE FRAGILE DELICATE INSTRUMENTDELICATE INSTRUMENTDELICATE INSTRUMENTDELICATE INSTRUMENT”. If corresponding with the factory or local Giga-tronics sales office regarding reshipment, please reference the full model number and serial number. If t
10、he instrument is being reshipped for repair, enclose all available pertinent data regarding the problem that has been found. NOTE: If you are returning an instrument to Giga-tronics for service, first contact Giga-tronics Customer Service at 800.444.2878 or Fax at 925.328.4702 so that a return autho
11、rization number can be assigned. You can also contact Customer Service via our e-mail address . Series 8540C Universal Power Meters 1-4Manual 30280, Rev. J, September 2000 1.2Safety Precautions This instrument has a 3-wire power cord with a 3-terminal polarized plug for connection to the power sourc
12、e and safety-ground. The ground (or safety ground) is connected to the chassis. If a 3-to-2 wire adapter is used, connect the ground lead from the adapter to earth ground. Failure to do this can cause the instru- ment to float above earth ground, posing a shock hazard. The 8540C is designed for inte
13、rnational use with source voltages of 100, 120, 220, or 240 Vac, 10% at 50 to 400 Hz. The 8540C uses an internationally approved connector that includes voltage selection, fuse, and filter for RFI protection (see Figure 1-1). The instrument can be damaged if connected to a source voltage with the li
14、ne voltage selector set incorrectly. Before connecting the instrument to power, make sure that the line voltage selector is set for the correct source voltage. 1.2.1Line Voltage and Fuse Selection The instrument is shipped in an operational condition and no special installation procedures are requir
15、ed except to check and/or set the operating voltage and fuse selection as described in the following. When the instrument is shipped from the factory, it is set for a power line voltage (120 Vac for domestic destinations). The power line fuse for this setting is 0.50 A Slo-Blo. If the source voltage
16、 is to be 220 to 240 Vac, the fuse must be changed to 0.35 A Slo-Blo (see Figure 1-1). Figure 1-1: Voltage Selector and Fuse Holder WARNING CAUTION 110 120 VOLTAGE SELECTION WHEEL COVER FUSE AND FUSE HOLDER AC POWER INPUT Introduction Manual 30280, Rev. J, September 20001-5 The voltage selector and
17、fuse holder are both contained in the covered housing directly above the AC power connector on the rear panel. To gain access to them, use a small screwdriver or similar tool to snap open the cover and proceed as follows: 1.To change the voltage setting: Use the same tool to remove the voltage selec
18、tor (a small barrel-shaped component marked with voltage settings). Rotate the selector so that the desired voltage faces outward and replace the selector back in its slot. Close the housing cover; the appropriate voltage should be visible through the window (see Figure 1-1). 2.To replace the fuse:
19、Pull out the small drawer on the right side of the housing (marked with an arrow) and remove the old fuse. Replace with a new fuse, insert the drawer and close the housing cover (see Figure 1-1). 1.2.2Power Sensor Precautions Power sensor safety precautions, selection, specifications, and calibratio
20、n are detailed in Appendix B to this manual. Series 8540C Universal Power Meters 1-6Manual 30280, Rev. J, September 2000 1.38540C System Specifications 1.3.1Power Meter Frequency Range:10 MHz to 40 GHz1 Power Range:-70 dBm to +47 dBm (100 pW to 50 Watt)1 Single Sensor Dynamic Range: CW Power Sensors
21、:90 dB1 Peak Power Sensors:40 dB Peak, 50 dB CW Modulation Sensors:87 dB CW; 80 dB MAP/PAP; 60 dB BAP Display Resolution:User-selective from 1 dB to 0.001 dB in Log mode and from 1 to 4 digits of display resolution in Linear mode. 1.3.2Accuracy CalibratorPower Sweep calibration signal to dynamically
22、 linearize the sensors Frequency:50 MHz nominal Settability:The 1 mW (0.0dBm) level in the Power Sweep Calibrator is factory set to 0.7% traceable to National Institute of Standards and Technology. Measure with 15 seconds of setting calibrator to 0.0 dBm. 0.0dBm Accuracy:1.2% worst case for one year
23、 over a temperature range of 5 to 35 C Connector:Type N, 50 VSWR:33 dB) System Linearity at 50 MHz for Standard Sensors:0.02 dB over any 20 dB range from -70 to +16 dBm 0.02 dB 0.05 dB/dB from +16 to +20 dBm 0.04 dB from -70 to +16 dBm Temperature Coefficient of Linearity:0.3%/ C temperature change
24、following Power Sweep Calibration. 24-hour warm-up required. Zeroing Accuracy (CW (Standard Sensors): Zero Set50 pW2 100 pW with 80400A and 80600A Series Modulation Power Sensors Zero Drift100 pW during 1 hour 2, 3 200 pW with 80400A and 80600A Series Sensors Noise50 pW measured over any 1 minute in
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 8540C 电路图 8540
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


