AN_99_06 电路图.pdf
《AN_99_06 电路图.pdf》由会员分享,可在线阅读,更多相关《AN_99_06 电路图.pdf(7页珍藏版)》请在收音机爱好者资料库上搜索。
1、Accurate RF Power Measurements of Second and Third Generation Wireless Communication Signals Notes Slide 1: In this seminar, we will be discussing different methods used for measuring power of modulated communication systems. While some of our examples will deal with cellular thermal sensors and dio
2、de sensors. Thermal sensors use either a thermocouple or a thermistor to measure the RF power. Both use the properties of heat to integrate the RF power over time. Due to the nature of thermal RadioFans.CN 收音机爱 好者资料库 characteristics, thermal sensors provide a slow response to changes in power, such
3、as when you have a modulated condition. Diode sensors rectify the RF energy to a dc voltage. The advantage of this method is that they are able to track very rapid changes in power if the sensor is designed properly. We will discuss the difference between tracking the average power of a modulated si
4、gnal and the peak power. For optimum performance, a diode sensor must have enough video bandwidth to track the peak envelope of the modulated signal. Notes Slide 5: When considering power measurement accuracy, or more correctly, measurement uncertainty, a number of factors must be taken into account
5、. The 8 factors listed here are the more significant ones. Mismatch uncertainty due to the interaction between the sensor and source is usually the most dominant. Then, factors such as instrumentation linearity, calibrator uncertainty and calibrator/sensor mismatch should be included. Finally, if th
6、e measurement takes place within the last 15 dB of dynamic range, zero and noise will become a major contributor to measurement uncertainty. Notice that these terms will change whenever there is a change in frequency, testport match, or power level. So in order to determine total measurement uncerta
7、inty, a complete analysis of each of these terms is required whenever power or frequency is changed. Giga-tronics has a paper that discusses how to calculate each of these terms manually. In addition, we have developed an Accuracy Audit program which takes the measurement information and automatical
8、ly converts the information into an uncertainty number. The program is a stand alone executable and is available on CD. If you would like a copy of the paper or the program, send us an email either directly to me or through our web site, and we will send you a CD with the materials. During this semi
9、nar, I will spend time discussing application concerns when measuring modulated signals rather than show how to calculate the individual uncertainties. Notes Slide 6: Here we have three classes of signals identified; Constant wave, or CW, where the amplitude is constant over time, Modulated Signals
10、and Digital Modulation. Digital communication signals use a combination of phase and amplitude modulation to code the carrier and have a more complex nature. Before talking about modulated measurements, lets first review how power meters measure CW signals. Notes Slide 7: We will first consider how
11、thermal sensors measure CW power and then compare that to a diode sensor. As mentioned previously, thermal sensors depend on the relationship between heat and power to determine the power level of the signal. The thermal sensor will therefore rise to the level of the power detected and eventually se
12、ttle to the final reading. Notes Slide 8: When measuring CW power with a diode sensor, the sensor samples the power at a given interval which is determined by the meter. The meter stores each of these samples in a bucket, averages all of the samples in the bucket and provides a measurement reading.
13、Averaging is the process of accumulating a number of buckets, averaging the readings and providing a single answer of all averaged buckets. So, if we were to set up the meter for an average of one, the meter would provide a reading from each bucket. When we talk about measurement speed, we are refer
14、ring to how fast the meter can provide measurements over the GPIB bus. Measurement speed therefore is determined by the speed of processing of measurements by the microprocessor. We can also see that the number of samples included in each measurement is determined by the sample rate. In Giga-tronics
15、 meters all of the samples are included in a measurement. If the RadioFans.CN 收音机爱 好者资料库 measurement speed decreases due to operating conditions, then the number of samples accumulated will increase. No samples are lost. Notes Slide 9: Lets review the operating characteristics of diode sensors. Dyna
16、mic range is a key feature for power meters. As mentioned during the introduction, the handset must be characterized over a wide dynamic range in order to optimize system efficiency. A thermal sensor will have a dynamic range of 40 to 50 dB. A diode sensor starts out with a linear dynamic range of 5
17、0 dB, from -70 dBm to around -20dBm. This is known as the square-law region of the sensor. It is also called the linear region since there is a linear relationship between the power in and the voltage out. Between -20 dBm and +20 dBm the diode sensor will operate, but it is not inherently linear. Gi
18、ga-tronics achieves a 90 dB dynamic range by characterizing the non-linear properties of the sensor during the front panel calibration. By storing the non-linear characteristics in the meter and recalling the correction data during measurements, the meter is able to provide a very linear dynamic ran
19、ge from -70 to +20 dBm. Notes Slide 10: This diagram explains further how Giga-tronics achieves a 90 dB dynamic range which is NIST traceable. We use a Wheatstone bridge which contains a thermistor as the reference. The thermistor is also called a bolometer and is a device whose measurement properti
20、es can be measured by NIST. A Wheatstone bridge with a thermistor is the method used by all power meters to establish a traceable 0 dBm reference for calibrating power sensors. What we have done in the Giga-tronics meters is included a patented process which incorporates stepped attenuators into the
21、 loop. Doing this allows us to step the power level from -30 to +20 dBm in 1 dB steps. This provides a very linear power sweep which is our reference for calibrating the sensor throughout the non-linear range and gives us a 90 dB dynamic range capability. Notes Slide 11: Lets return to a CW measurem
22、ent except this time we will measure a low level signal that is close to the noise floor of the meter. Notice that we no longer have a constant level power. Average power in this case is the mean of the power variations over time. We obtain the average power by accumulating a number of readings and
23、using the average function of the meter. Both the thermal and diode sensors will settle to the average power. The diode sensor has the potential to settle much faster with a fast sample rate. A fast sample rate provides a large number of readings very quickly allowing the meter to average the measur
24、ements and settle to the reading. Notice that one of the characteristics of noise is the normal distribution around the mean. Notes Slide 12: We will now start to evaluate modulation measurements by first examining a two tone, AM modulated signal. Notice that we are skipping FM modulation measuremen
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AN_99_06 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


