1、Service-Manual U n i v e r s a l C o u n t e r H M 8 0 2 1 - 4 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual generic- an
2、d product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industrial environment have been used. The measuri
3、ng- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and conditions regarding emission and immunity s
4、hould be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length, the maximum cable length of a dataline mu
5、st be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ72S and HZ72L from HAMEG are suitable.
6、2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings. Signal lines must screened (coaxial ca
7、ble - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi elds, even with careful setup of the measur
8、ing equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in individual cases. HAMEG Instruments GmbH Die H
9、AMEG Instruments GmbH bescheinigt die Konformitt fr das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit Bezeichnung / Product name / Designation: Universal Zhler / Universal Counter / Compteur Universel Typ / Type
10、/ Type: HM8021-4 mit / with / avec: HM8001-2 Optionen / Options / Options: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes EMV Richtlinie 89/336/EWG ergnzt durch 91/263/EWG, 92/31/EWG EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC
11、 89/336/CEE amende par 91/263/EWG, 92/31/CEE Niederspannungsrichtlinie 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Directive des equipements basse tension 73/23/CEE amende par 93/68/CEE Angewendete harmonisierte Normen / Harmonized standards applie
12、d / Normes harmonises utilises Sicherheit / Safety / Scurit EN 61010-1:2001 (IEC 61010-1:2001) berspannungskategorie / Overvoltage category / Catgorie de surtension: II Verschmutzungsgrad / Degree of pollution / Degr de pollution: 2 Elektromagnetische Vertrglichkeit / Electromagnetic compatibility /
13、 Compatibilit lectromagntique Hersteller HAMEG Instruments GmbH KONFORMITTSERKLRUNG Manufacturer Industriestrae 6 DECLARATION OF CONFORMITY Fabricant D-63533 Mainhausen DECLARATION DE CONFORMITE EN 61326-1/A1 Straussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class / Classe
14、B. Strfestigkeit / Immunity / Imunitee: Tabelle / table / tableau A1. EN 61000-3-2/A14 Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique: Klasse / Class / Classe D. EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de t
15、ension et du fl icker. Datum /Date /Date 22.07.2004 Unterschrift / Signature /Signatur G. Hbenett Produktmanager General information regarding the CE marking RadioFans.CN 收音机爱 好者资料库 3 Subject to change without notice Content Declaration of Conformity 2 General information regarding the CE-marking 2
16、4 Digit Programmable Multimeter HM8021-4 4 Specifi cations 5 Control elements 6 Adjustment 7 Circuit and layout diagrams 8 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8021-4 1 . 6 G H z U n i v e r s a l C o u n t e r H M 8 0 2 1 - 4 Frequency range 0Hz to 1.6GHz 10MHz time base wit
17、h 0.5ppm stability (TCXO) Input A: Input impedance 1M, maximum sensitivity 20mVrms Input C: Input impedance 50, maximum sensitivity 30mVrms Time interval resolution up to 10ps Offset mode over the entire measurement range Gate input (in combination with HO801) Mainframe HM8001-2 required for operati
18、on Option HO801 Mainframe HM8001-2 Option HO85, a high-stability oscillator with a stability of 5x10 -9 per day 5 Subject to change without notice Specifications 1.6 GHz Universal Counter HM8021-4 Valid at 23 C after a 30 minute warm-up period Measurement functions Frequency A/C, Period A; Totalize
19、A; Pulse width : L / L :(averaged); Totalize A during ext. gate Input characteristics (Input A) Frequency range: 0 150MHz:DC-coupled 10Hz 150MHz:AC-coupled Sensitivity: (normal triggering) DC 80MHz20mVrms(sine wave) 80mV (pulse) 80MHz 150MHz60mVrms(sine wave) 20Hz 80MHz (auto trig.) 50mVrms(sine wav
20、e) Minimum pulse width:5ns Input noise:100V (typ.) Coupling:AC or DC (switchable) Input impedance:1M II 40pF Attenuator:x 1, x 20 (switchable) Max. input voltage: 0 to 440Hz:400V (DC + ACpeak) 1MHz:decreasing to 8Vrms Input characteristics (Input C) Frequency range:100MHz 1.6GHz Sensitivity: to 1.3
21、GHz:30mV (typ. 20mV) to 1.6 GHz: 100mV (typ. 80mV) Input impedance:50 nominal Coupling:AC Max. input voltage: 5V (DC + ACpeak) Input characteristics (external gate) Input impedance:4.7k Max. input voltage:30V High/low level: 2V/ 0.5V Min. pulse duration: 50ns Min. effective gate time:150s Frequency
22、measurement (Input A) LSD:(2.5x10-7s x freq.)/measurement time Resolution:1 or 2 LSD Period duration measurement Range:10000 sec to 66.6ns LSD:(2.5 x 10-7s x period)/measurement time Resolution:1 or 2 LSD Totalize (manual / external gated) Range:DC to 20MHz Min. pulse duration:25ns LSD:1 count Resol
23、ution:LSD Ext. gate error: in manual mode only 100ns Time interval (averaged) LSD:100ns to 10ps Resolution:1 or 2 LSD Offset Range:covers the entire measurement range Gate time (Gate time cannot be less than 1 period.) Range:100ms 10s in 3 steps External gate time:min. 150 s Timebase Frequency:10MHz