Gould os4000manual 电路图.pdf
《Gould os4000manual 电路图.pdf》由会员分享,可在线阅读,更多相关《Gould os4000manual 电路图.pdf(68页珍藏版)》请在收音机爱好者资料库上搜索。
1、DIGITAL STORAGE OCILLOSCOPE 054000 Instruction Manual -GOULD Telephone 01-5001000 Telegrams AttenuateIlford Telex 263785 RadioFans.CN 收音机爱 好者资料库 Contents SECTION1Introduction4ILLUSTRATIONS Fig.1Alias Effects10 SECTION2Specification5Fig.2Block Diagram of Instrument12 Fig.3Block Diagram of ADC16 SECTI
2、ON3OperatingInstructions6Fig.4TypicalSignal Waveforms(ADC)17 3.1Supplies6Fig.5TimingSignal Waveforms(ADC)18 3.2C.R.T. Controls6Fig.6TimingChart (ADC)19 3.3Y Channel Controls6Fig.7Logic Block Diagram: 3.4Timebase Controls6Refreshed Mode20 3.5Store Controls7Fig.8Tim ing Diagram:Refreshed 3.6Alias Effe
3、cts8Mode21 3.7AdditionalFacil ities9Fig.9Tim ing Diagram:Address 3.8FunctionalChecks9Sequence22 Fig. 10Logic Block Diagram:Roll Mode 23 SECTION4CIRCUITDESCRIPTION12Fig. 11TimingDiagram:Roll Mode24 4.1SystemDescription12Fig. 12SimplifiedControlLogic28 4.2Power Supplies13Fig. 13Timebase Block Diagram:
4、 4.3Y Amplifier14NormalMode30 4.4Analogue-DigitalConverter16Fig. 14BottomView37 4.5Store and ControlLogic20Fig. 15RighthandView37 4.6Mode Control27Fig. 16RighthandView:Maintenance 4.7Trigger and Timebase30Position38 4.8D-A Converterand Dot Joiner34Fig. 17ControlConditionTable40 4.9Calibrator35Fig. 1
5、8Data Faults50 Fig. 19ADC Waveforms51 SECTION5Maintenance36Fig. 20CircuitDiagram:Power Supplies, 5.1General36Y Outputand Blanking57 5.2MechanicalAssembly36Fig. 21CircuitDiagram:Pre-amplifiers59 5.3Fault Finding39Fig. 22CircuitDiagram:A-D Converter63 5.4CalibrationProcedure52Fig. 23CircuitDiagram:Tim
6、ingand 5.5Wiring details for l00Voperation52Store Logic69 Fig. 24CircuitDiagram:Timebase71 SECTION6CircuitDiagrams and Fig. 25CircuitDiagram:D-A Converter ComponentSchedules55 and Dot Joiner73 SECTION7Guarantee and Service Facilities79 Fig. 26InterconnectionDiagram75 Fig. 27MechanicalViews 77 RadioF
7、ans.CN 收音机爱 好者资料库 The Gould Advance OS4000 Digital Storage Oscilloscope is a versatile instrumentwhich combines conventional lOMHz oscilloscope performancewith a digital storage system, capable of storing signals up to 450kHz.The digital method of storage offers several advantages over the more comm
8、on tube storage, notably the facility of pre-trigger viewing, the simultaneousviewing of a stored and a real-time display, absence of deteriorationof the stored display with time, completelyflicker free, low frequency performance,and the abolition of the very expensive storage tube. Careful attentio
9、nto the ergonomic design allows the OS4000 to be operated in the same way as a conventional Section 1 oscilloscope with the addition of the minimum number of additional controls for the storage functions. APPLICATIONS The OS4000 isideally suited for viewing: 1. Transient waveforms, e.g. in Medical,
10、dynamic testing, vibration, pulse testing application. 2. All LF applications where the Refresh mode eliminates flicker.The slowest sweep speed of 200s maximum allows the instrumentto be used for new classes of viewing application. 3. Normal (real time) viewing with the 10MHz real time performance.
11、4. Comparisons between stored and real time waveforms. RadioFans.CN 收音机爱 好者资料库 Specification DISPLAY 8 x 10 cm rectangular CRT operating at 4kV Illuminatedgraticule VERTICAL DEFLECTION Two identical input channels Bandwidth:DC-lOMHz in the Normal mode Sensitivity:5mV/cm to 20V/cm in 12 ranges Uncali
12、bratedfine gain control gives between range sensitivity adjustment Accuracy: 3% in calibrated positions Input Impedance:IM/28pF Input Coupling:AC-GND-DC Maximum Input:400V DC or pk AC HORIZONTAL DEFLECTION Timebase:Ills/cm to 20 sec/cm in 23 rangesJ-Jkb . +XJOt.siA$a Accuracy.- 3%IMCcrcc;I SIVVC/L.
13、X Expansion:Continuouslyvariable from IX to 10X with calibrated stops at each end TRIGGER Source:CHl, CH2, Ext, or line Coupling:AC, LF Rej., HF Rej, DC Sensitivity:Internal 2mm approx., DC-2MHz (lcm at 10MHz) External IV approx. DC-2MHz (5Vat10MHz) Bright Line:Available on normal operationonly DISP
14、LAY VIA STORE Store size:1024 x 8 bits Vertical Resolution:Approx. 200 for 8cm display, Le. 25 steps per(;m HORIZONTALRESOLUTION Single Trace:Approx. 1000 samples for complete scan (lOO samples/cm) Double TraceApprox. 500 samples for complete scan or Alt. Lock:(50 samples/cm) Maximum Sample Rate:1.8
15、MHz(0.55Ils) Section 2 FASTEST RISE TIME For step response:0.551lssingle trace I.Ills dual trace or Alt. Lock (EquivalentBandwidth 600kHz and 300kHz) Maximum Storage450kHz single trace Frequency - 3 db:225kHz dual trace or Alt. Lock Limited Store:For timebase speeds faster than SOils/cmthe number of
16、 samples per cm is reduced in proportionto the sweep rate. For speeds slower than SOils/cmthe maximum stored bandwidth is reduced in proportionto the sweep rate Dot Joining:The expanded display appears as straight lines joining consecutive samples rather than as distinct dots ACCESSORIES SUPPLIED Ha
17、ndbook PN 36240 2 x Lead PL44BNC-clip 2 x Lead PL43BNC-BNC Supplies:Il5V,220V, 240V 10% 45-400Hz,55W Size:17.8 x 31.2 x 41.7 (7 x 12% x 16*) Weight:Approx. 11 kg (24% Ib) TemperatureRange:Operating 0 to 50C Full spec. 15 to 35C OPTION 4001 This add-on option provides analogue outputs to allow the tr
18、ace to be recorded on strip chart, X Y or T Y recorders and digital outputs for further processing of the recorded data.(See data sheet.) Operation 3.1SUPPLI ES The instrumentis normally despatchedfrom the factory with the supply range switch on the rear panel set to the 240V(10%) range. Check that
19、this is set correctly before connecting to the supply.Note that the correct fuse for the two high voltage ranges, 220V and 240V, is 500mA Slo-Blo (20mm) Advance Part No. 33685.If the 115V range is selected the fuse should be changed to a lA Slo-Blo Advance Part No. 34790. NOTE: DO NOT CHANGE THE SUP
20、PLY RANGE SWITCH WITH THE INSTRUMENT CONNECTED TO THE SUPPLY. While the instrumentdoes not rely on forced air circulation,it should not be operated at elevated temperaturesif the natural connectioncooling is restricted,particularlyat the rear of the instrument. The instrumentis switched on by pressi
21、ng the POWER buttonwhen the associated neon indicator should light. The buttonis self locking and the instrumentis switched off by pressing the buttonagam. 3.2C.R.T. CONTROLS These controls are grouped to the right of the c.r.t. display. IntensityThis is used to set optimum trace intensity depending
22、 on ambient lighting conditions. FocusUsed to obtain finest possible trace width. ScaleThe un-illuminatedgraticule is easily visible under normal lighting conditions.Graticule illuminationis usually only reqUired under low ambient light conditionsor when photo- graphically recording the display.The
23、intensity will depend on the film speed, aperture and exposure time being used. The graticule has 0, 10, 90,100%lines marked to assist in rise time measurement. 3.3Y CHANNELCONTROLS These controls are grouped beneath the c.r.t. display. The input signal is applied to the CHI or CH2 BNC input socket.
24、 Coupling For direct connectionof the input signal, set the associated AC-Ground-DC input iever switch to DC. For capacitive coupling of the input signal through an internal O.lpF 400V capacitor, set the lever switch to AC. NOTE: When examining low amplitude a.c. signals super- imposed on.a high d.c