1、Service-Manual 3 - D i g i t L C R - M e t e r H M 8 0 1 8 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by
2、 HAMEG is based on the actual generic- and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industria
3、l environment have been used. The measuring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and con
4、ditions regarding emission and immunity should be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length,
5、the maximum cable length of a dataline must be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables
6、HZ72S and HZ72L from HAMEG are suitable. 2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside building
7、s. Signal lines must screened (coaxial cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi el
8、ds, even with careful setup of the measuring equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in indiv
9、idual cases. HAMEG Instruments GmbH KONFORMITTSERKLRUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACIN DE CONFORMIDAD Hersteller / Manufacturer / Fabricant / Fabricante: HAMEG Instruments GmbH Industriestrae 6 D-63533 Mainhausen Die HAMEG Instruments GmbH bescheinigt die Konformitt f
10、r das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit HAMEG Instruments GmbH certifi ca la conformidad para el producto Bezeichnung: LCR-Meter Product name: LCR meter Designation: LCR mtre Descripcin: Medidor de LC
11、R Typ / Type / Type / Tipo: HM8018 mit / with / avec / con: HM8001-2 Optionen / Options / Options / Opcines: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes / con las siguientes directivas: EMV Richtlinie 89/336/EWG ergnzt durch 91/263/EWG, 92/31/EWG EMC
12、Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG, 92/31/CEE Directiva EMC 89/336/CEE enmendada por 91/263/CEE, 92/31/CEE Niederspannungsrichtlinie 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Direc
13、tive des equipements basse tension 73/23/CEE amende par 93/68/CEE Directiva de equipos de baja tensin 73/23/CEE enmendada por 93/68/EWG Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonises utilises / Normas armonizadas utilizadas: Sicherheit / Safety / Scurit / Segurid
14、ad: EN 61010-1: 1993 / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994 berspannungskategorie / Overvoltage category / Catgorie de surtension / Categora de sobretensin: II Verschmutzungsgrad / Degree of pollution / Degr de pollution / Nivel de polucin: 2 Elektromagnetische Vertrglichkeit / Electrom
15、agnetic compatibility / Compatibilit lectromagntique / Compatibilidad electromagntica: EN 61326-1/A1: Straussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class / Classe / classe B. Strfestigkeit / Immunity / Imunitee / inmunidad: Tabelle / table / tableau / tabla A1. EN 61000
16、-3-2/A14: Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique / emisin de corrientes armnicas: Klasse / Class / Classe / clase D. EN 61000-3-3: Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de tension et du fl icker / fl uctuacion
17、es de tensin y fl icker. Datum / Date / Date / Fecha 22.07.2004 Unterschrift / Signature / Signatur / Signatura G. Hbenett Product Manager RadioFans.CN 收音机爱 好者资料库 3 Subject to change without notice Content Declaration of Conformity 2 General information regarding the CE-marking 2 3-Digit LCR-Meter H
18、M8018 4 Specifi cations 5 Alignment procedure 6 Circuit and layout diagrams 7 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8018 Measurement functions: L, C, R 3 -digit display with 2,000 counts, basic accuracy 0.5% 4-wire measurement Max. resolution: 0.1pF, 0.1H, 10m, 0.01S Internal
19、bias for electrolytic capacitors selectable Offset adjustment of cable capacity for the “Kelvin test lead“ AC voltage signal at rear-panel BNC connector proportional to value shown in the display (with Option HO801 only) Mainframe HM8001-2 required for operation Option HZ18 Kelvin test lead Option H