Hameg HM303-4 电路图.pdf
《Hameg HM303-4 电路图.pdf》由会员分享,可在线阅读,更多相关《Hameg HM303-4 电路图.pdf(44页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Instruments Oscilloscope HM 303-4 ENGLISH 4S-0303-04E0 10 JUN 1998 SERVICE-MANUALHM303-4 RadioFans.CN 收音机爱 好者资料库 Subject to change without notice 1 Y-Preamplifier CH I (YP-Board). 4 Y-Preamplifier CH II (YP-Board). 5 Y-Intermediate Amplifier and Trigger Amplifier (YP-Board) . 6 YPA-Board (Top side)
2、. 7 YPA-Board (Bottom side) . 8 XY-Amplifier, YF-Amplifier, OS-Circuit . 9 XY-Board (Top side) . 10 XY-Board (Bottom side). 11 Sync.-Amplifier. 12 Time base . 13 Sweep-Generator . 14 TB-Board . 15 CRT-Board . 16 CRT-Board (Top and Bottom side) . 17 Power Supply (PS-Board). 18 PS-Board (Top side). 19
3、 PS-Board (Bottom side) . 20 Component tester, Calibrator . 21 CCT-Board (Top and Bottom side) . 22 Front-Control Board. 23 Front-Control Board (Top and Bottom side) . 24 ADJUSTMENT PROCEDURE . 25 Table of contents Service Manual Circuit Diagrams Adjustment Procedure HM303-4 St. 100698. Hb/goRR Radi
4、oFans.CN 收音机爱 好者资料库 Subject to change without notice 2 RadioFans.CN 收音机爱 好者资料库 Subject to change without notice 3 30MHz Standard Oscilloscope HM303 Accessories supplied: Line cord, Operators Manual, 2 Probes 1:1/10:1 Specifications Vertical Deflection Operating modes: Channel I or II separate, both
5、Channels (alternated or chopped), (Chopper frequency approx. 0.5MHz). Sum or difference with Ch. I and Ch. II (both channels invertable). XY-Mode: via channel I and channel II Frequency range: 2xDC to 30MHz (3dB) Risetime: 12ns. Overshoot 1%. Deflection coefficients: 12 calibrated steps from 5mV/div
6、. to 20V/div. (1-2-5 sequence) with variable 2.5:1 up to 50V/div. Accuracy in calibrated position: 3% Y-expansion x5 (calibrated) to 1mV/div. (5%) in the frequency range from DC - 10MHz (3dB) Input impedance: 1M II 20pF. Input coupling: DC-AC-GD (ground). Input voltage: max. 400V (DC + peak AC). Tri
7、ggering Automatic: (peak to peak) 20Hz-100MHz ( 0.5div.) Normal with level control: DC-100MHz (0.5div.) ALT. Triggering; LED indicator for trigger action Slope: positive or negative, Sources: Channel I or II, CH. I alternating CH II, line, external Coupling: AC (10Hz to 100MHz), DC (0 to 100MHz), LF
8、 (0 to 1.5kHz) Active TV-Sync-Separator (pos. and neg.) External: 0.3p-p from 30Hz to 30MHz Horizontal Deflection Time coefficients: 20 calibrated steps from 0.2s/div. - 0.1s/div. in 1-2-5 sequence Accuracy in calibrated position: 3%. Min. speed incl. variable 2.5:1 up to 0.5s/div. with X-Mag. x10:
9、5%; 10ns/div.: 8% Holdoff time: variable to approx. 10:1 Bandwidth X-amplifier: 0-3MHz (3dB). Input X-Amplifier via Channel II, (sensitivity see Channel II specification) X-Y phase shift: 3 below 220kHz. Component Tester Test voltage: approx. 6Vrms (open circuit). Test current: approx. 5mArms (short
10、ed). Test frequency: approx. 50Hz Test connection: 2 banana jacks 4mm One test lead is grounded (Safety Earth) General Information CRT: D14-364GY/123 or ER151-GH/-, 6 rectangular screen (8x10cm) internal graticule Acceleration voltage: approx 2000V Trace rotation: adjustable on front panel Calibrato
11、r: square-wave generator (tr 4ns) 1kHz / 1MHz; Output: 0.2V 1% and 2V Line voltage: 100-240V AC 10%, 50/60Hz Power consumption: approx. 36 Watt at 50Hz. Min./Max. ambient temperature: 0C.+40C Protective system: Safety class I (IEC 1010-1) Weight: approx. 5.6kg, color: techno-brown Cabinet: W 285, H
12、125, D 380 mm Lockable tilt handle 5/96 Screen photo of 1 MHz square wave signal Screen photo of 50 and 100MHz sine wave with alternate triggering The new HAMEG HM303 oscilloscope succeeds the HM203 (over 170,000 sold worldwide). The bandwidth has been extended from 20 to 30MHz, the sweep rate incre
13、ased to 10ns/div. and improvements added to the already legendary HAMEG auto triggering system. The HM303 is the ideal instrument for waveform display in the DC to 100MHz frequency range. A key feature of this oscilloscope is the vertical amplifiers pulse fidelity, limiting overshoot to only 1%. The
14、 HM303 offers a special fast rise time 1kHz/1MHz Calibrator, permitting high quality probe compensation across the entire frequency range to ensure probe-tip thru to display integrity. An Overscan Indicator assists in vertical display amplitude and position adjustment. The HM303 is capable of trigge
15、ring on input waveforms over 100MHz and on signal levels as small as 0.5 division. Alternate triggering mode enables the display of two asynchronous signals simultaneously. An active Video Sync- Separator permits detailed examination of complex TV signal inputs. A well proven, built-in component tes
16、ter is now equipped with a stabilized measuring voltage. The use of a switching type of power supply minimizes both weight and power consumption and universally accepts a wide range of input power line voltages, without the requirement to change jumpers or switch positions. The HM303s CRT is fully m
17、u-metal shielded against outside magnetic fields. HAMEG is setting new price/performance breakthroughs with the introduction of this fine oscilloscope. This performance packed scope will tempt all users to run it through its paces. OSCILLOSCOPES Dual Channel, DC to 30MHz, 1mV/div.; Overscan Indicato
18、r Time Base: 0.2s to 10ns/div.; Variable Holdoff; Alternate Triggering Triggering: DC-100MHz; Auto Peak to Peak; Active TV-Sync-Separator Additional Features: Component Tester, 1kHz/1MHz Calibrator Subject to change without notice 4 Y-Preamplifier CH I (YP-Board) Subject to change without notice 5 Y
19、-Preamplifier CH II (YP-Board) Subject to change without notice 6 Y-Intermediate Amplifier and Trigger Amplifier (YP-Board) Subject to change without notice 7 YPA-Board (Top side) Subject to change without notice 8 YPA-Board (Top side) Subject to change without notice 9 XY- Amplifier, YF- Amplifier,
20、 OS- Circuit Subject to change without notice 10 XY Board (Top side) Subject to change without notice 11 XY Board (Top side) Subject to change without notice 12 Sync.- Amplifier Subject to change without notice 13 Time base Subject to change without notice 14 Sweep- Generator Subject to change witho
21、ut notice 15 TB Board Subject to change without notice 16 CRT- Board Subject to change without notice 17 CRT Board (Top and Bottom side) Subject to change without notice 18 Power Supply (PS-Board) A B C D 87654321 D C B A 12345678 Title :Rev.: R Date : Document Number : MPT MPT MPT MPT MPT MPT MPT M
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Hameg HM303-4 电路图 HM303
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf