Hameg HM8012 Multimeter - Service manual 电路图.pdf
《Hameg HM8012 Multimeter - Service manual 电路图.pdf》由会员分享,可在线阅读,更多相关《Hameg HM8012 Multimeter - Service manual 电路图.pdf(28页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service-Manual 4 - D i g i t M u l t i m e t e r H M 8 0 1 2 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual generic- and
2、product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industrial environment have been used. The measuring
3、- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and conditions regarding emission and immunity sho
4、uld be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length, the maximum cable length of a dataline must
5、 be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ72S and HZ72L from HAMEG are suitable. 2.
6、 Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings. Signal lines must screened (coaxial cabl
7、e - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi elds, even with careful setup of the measurin
8、g equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in individual cases. HAMEG Instruments GmbH Die HAM
9、EG Instruments GmbH bescheinigt die Konformitt fr das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit Bezeichnung / Product name / Designation: Multimeter / Multimeter / Multimtre Typ / Type / Type: HM8012 mit / wi
10、th / avec: Optionen / Options / Options: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes EMV Richtlinie 89/336/EWG ergnzt durch 91/263/EWG, 92/31/EWG EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG,
11、 92/31/CEE Niederspannungsrichtlinie 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Directive des equipements basse tension 73/23/CEE amende par 93/68/CEE Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonises utilises Sic
12、herheit / Safety / Scurit EN 61010-1:2001 (IEC 61010-1:2001) berspannungskategorie / Overvoltage category / Catgorie de surtension: II Verschmutzungsgrad / Degree of pollution / Degr de pollution: 2 Elektromagnetische Vertrglichkeit / Electromagnetic compatibility / Compatibilit lectromagntique Hers
13、teller HAMEG Instruments GmbH KONFORMITTSERKLRUNG Manufacturer Industriestrae 6 DECLARATION OF CONFORMITY Fabricant D-63533 Mainhausen DECLARATION DE CONFORMITE EN 61326-1/A1 Straussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class / Classe B. Strfestigkeit / Immunity / Imun
14、itee: Tabelle / table / tableau A1. EN 61000-3-2/A14 Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique: Klasse / Class / Classe D. EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de tension et du fl icker. Datum /Date
15、 /Date 22.07.2004 Unterschrift / Signature /Signatur G. Hbenett Produktmanager General information regarding the CE marking RadioFans.CN 收音机爱 好者资料库 3 Subject to change without notice Content Declaration of Conformity 2 General information regarding the CE-marking 2 4 Digit Programmable Multimeter HM
16、8012 4 Specifi cations 5 Control elements 6 Function test 7 Calibration 8 Circuit and layout diagrams 9 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8012 4 -digit display with 50,000 counts, basic accuracy 0.05% Automatic and manual range selection Max. resolution 10V, 0.01dBm, 10nA,
17、 10m, 0.1 C/ F Offset function / relative value measurement in basic measurement functions Input impedance 1G (0.5V and 5V DC range) RS-232 interface PC software for control and data logging Mainframe HM8001-2 required for operation 34 4 - D i g i t P r o g r a m m a b l e M u l t i m e t e r H M 8
18、0 1 2 34 WDM8012 Software (included) HZ15 (included) WDM8012 Software (included) 5 Subject to change without notice Specifications 4 -Digit programmable Multimeter HM8012 Valid at 23 C after a 30 minute warm-up period DC voltage Measurement ranges:500mV, 5V, 50V, 500V, 600V Resolution:10V, 100V, 1mV