Hameg hm8027-serv 电路图.pdf
《Hameg hm8027-serv 电路图.pdf》由会员分享,可在线阅读,更多相关《Hameg hm8027-serv 电路图.pdf(12页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service-Manual D i s t o r t i o n M e t e r H M 8 0 2 7 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by H
2、AMEG is based on the actual generic- and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industrial
3、environment have been used. The measuring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and condi
4、tions regarding emission and immunity should be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length, th
5、e maximum cable length of a dataline must be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ
6、72S and HZ72L from HAMEG are suitable. 2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings.
7、 Signal lines must screened (coaxial cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi elds
8、, even with careful setup of the measuring equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in individ
9、ual cases. HAMEG Instruments GmbH KONFORMITTSERKLRUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACIN DE CONFORMIDAD Hersteller / Manufacturer / Fabricant / Fabricante: HAMEG Instruments GmbH Industriestrae 6 D-63533 Mainhausen Die HAMEG Instruments GmbH bescheinigt die Konformitt fr
10、das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit HAMEG Instruments GmbH certifi ca la conformidad para el producto Bezeichnung: Klirrfaktor Messbrcke Product name: Distortion Meter Designation: Distorsiomtre Des
11、cripcin: Medidor de distorsin Typ / Type / Type / Tipo: HM8027 mit / with / avec / con: HM8001-2 Optionen / Options / Options / Opcines: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes / con las siguientes directivas: EMV Richtlinie 89/336/EWG ergnzt durc
12、h 91/263/EWG, 92/31/EWG EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG, 92/31/CEE Directiva EMC 89/336/CEE enmendada por 91/263/CEE, 92/31/CEE Niederspannungsrichtlinie 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EE
13、C amended by 93/68/EEC Directive des equipements basse tension 73/23/CEE amende par 93/68/CEE Directiva de equipos de baja tensin 73/23/CEE enmendada por 93/68/EWG Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonises utilises / Normas armonizadas utilizadas: Sicherheit
14、 / Safety / Scurit / Seguridad: EN 61010-1: 1993 / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994 berspannungskategorie / Overvoltage category / Catgorie de surtension / Categora de sobretensin: II Verschmutzungsgrad / Degree of pollution / Degr de pollution / Nivel de polucin: 2 Elektromagnetisc
15、he Vertrglichkeit / Electromagnetic compatibility / Compatibilit lectromagntique / Compatibilidad electromagntica: EN 61326-1/A1: Straussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class / Classe / classe B. Strfestigkeit / Immunity / Imunitee / inmunidad: Tabelle / table /
16、tableau / tabla A1. EN 61000-3-2/A14: Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique / emisin de corrientes armnicas: Klasse / Class / Classe / clase D. EN 61000-3-3: Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de tension e
17、t du fl icker / fl uctuaciones de tensin y fl icker. Datum / Date / Date / Fecha 22.07.2004 Unterschrift / Signature / Signatur / Signatura G. Hbenett Product Manager RadioFans.CN 收音机爱 好者资料库 3 Subject to change without notice Content Declaration of Conformity 2 General information regarding the CE-m
18、arking 2 Distortion meter HM8027 4 Specifi cations 5 Control elements 6 Operational check 6 Ajustment 7 Circuit and layout diagrams 8 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8027 D i s t o r t i o n M e t e r H M 8 0 2 7 Frequency range 20Hz to 20kHz Resolution up to 0.01% Low i
19、nherent distortion of 0.005% Automatic frequency fine tuning (capture range 15%) Control output for residual distortion measurement A complete measurement system for AF measurement equipment in combination with the HM8037 Mainframe HM8001-2 required for operation HM8037 Low-distortion sine wave gene
20、rator Mainframe HM8001-2 HZ32 Test cable 5 Subject to change without notice Specifications HM8014E/140705/ce Subject to alterations HAMEG Instruments GmbH Registered Trademark DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM HAMEG Instruments GmbH Industriestr. 6 D-63533
21、 Mainhausen Tel +49(0)6182 8000 Fax +49(0)6182 800100 A Rohde & Schwarz Company w w w. h a m e g . co m Monitor output Output voltage:1mV/digit (short-circuit proof) Output impedance:10k Input attenuation 1 constant attenuator 20dB 1 constant attenuator 10dB 1 variable attenuator 15dB Miscellaneous
22、1 selectable high-pass filter: 1 kHz, 12 dB/octave Power supply +12V/60mA (from mainframe):- 12V/60mA +5V/100mA ( = 1.94W) Operating temperature:+10C to +40C Max. relative humidity:80% (without condensation) Dimensions (W x H x D) (without 22-pole flat plug): 135 x 68 x 228mm Weight:approx. 0.65kg A
23、ccessories supplied: Operators Manual Optional accessories: HZ33/HZ34 BNC Test Cable, HZ20 BNC banana adapter, HZ10 Silicone test leads Distortion Meter HM8027 Valid at 23 C after a 30 minute warm-up period Frequency range 20Hz - 20kHz subdivided into 3 ranges variable frequency control 10:1, overla
24、pping ranges Distortion measurement range 0.01% - 50%, subdivided into 2 ranges Full range:10% and 100% Display resolution:100% range: 0.1% 10% range: 0.01% Display accuracy 100% range:5% 1 digit for k 10% 10% range: 5% 1 digit for k 1% Inherent distortion + noise 0.5 digit Fundamental rejection 30