Hameg hm8030 电路图.pdf
《Hameg hm8030 电路图.pdf》由会员分享,可在线阅读,更多相关《Hameg hm8030 电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service-Manual F u n c t i o n G e n e r a t o r H M 8 0 3 0 - 6 RadioFans.CN 收音机爱 好者资料库 2 Subject to change without notice General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual generic-
2、and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industrial environment have been used. The measu
3、ring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and conditions regarding emission and immunity
4、 should be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length, the maximum cable length of a dataline
5、must be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ72S and HZ72L from HAMEG are suitable
6、. 2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings. Signal lines must screened (coaxial
7、cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi elds, even with careful setup of the meas
8、uring equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in individual cases. HAMEG Instruments GmbH Gen
9、eral information regarding the CE marking Sicherheit / Safety / Scurit: EN 61010-1: 1993 / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994 EN 61010-1/A2: 1995 / IEC 1010-1/A2: 1995 / VDE 0411 Teil 1/A1: 1996-05 berspannungskategorie / Overvoltage category / Catgorie de surtension: II Verschmutzung
10、sgrad / Degree of pollution / Degr de pollution: 2 Elektromagnetische Vertrglichkeit / Electromagnetic compatibility / Compatibilit lectromagntique EN 61326-1/A1 Straussendung / Radiation / Emission: Tabelle / table / tableau 4, Klasse / Class / Classe B. Strfestigkeit / Immunity / Imunitee: Tabelle
11、 / table / tableau A1. EN 61000-3-2/A14 Oberschwingungsstrme / Harmonic current emissions / missions de courant harmonique: Klasse / Class / Classe D. EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations de tension et du fl icker. Datum/Date/Date 22.07.20
12、04 Unterschrift / Signature /Signatur Manuel Roth Manager Hersteller HAMEG Instruments GmbH KONFORMITTSERKLRUNG Manufacturer Industriestrae 6 DECLARATION OF CONFORMITY Fabricant D-63533 Mainhausen DECLARATION DE CONFORMITE Die HAMEG Instruments GmbH bescheinigt die Konformitt fr das Produkt The HAME
13、G Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH dclare la conformite du produit Bezeichnung / Product name / Designation: Funktionsgenerator Function generator Gnrateur de fonctions Typ / Type / Type: HM8030-6 mit / with / avec: HM8001-2 Optionen / Options / Opt
14、ions: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes EMV Richtlinie 89/336/EWG ergnzt durch 91/263/EWG, 92/31/EWG EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG, 92/31/CEE Niederspannungsrichtlini
15、e 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Directive des equipements basse tension 73/23/CEE amende par 93/68/CEE Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonises utilises RadioFans.CN 收音机爱 好者资料库 3 Subject to c
16、hange without notice Content Declaration of Conformity 2 General information regarding the CE-marking 2 Function Generator HM8030-6 4 Specifi cations 5 Control elements 6 Adjustment 7 Circuit and layout diagrams 9 RadioFans.CN 收音机爱 好者资料库 4 Subject to change without notice HM8030-6 1 0 M H z F u n c
17、t i o n G e n e r a t o r H M 8 0 3 0 - 6 Frequency range 50mHz to 10MHz High signal purity and amplitude stability Distortion factor 0.5% up to 1 MHz Output voltage 20Vpp(10Vppinto 50) Surge- and short-circuit-proof output Rise and fall time typ. 15 ns Internal and external sweep Pulse width adjust
18、ment Highly accurate digital frequency display Mainframe HM8001-2 required for operation HZ20 Connector BNC to 4mm socket Option HO801 HZ33, HZ34 Test cable BNC/BNC 5 Subject to change without notice Specifications Accessories supplied: Operators Manual Optional accessories: HZ33/HZ34 BNC Test Cable
19、, HZ22 50 feed-through terminal, HZ10 Silicone test leads 10 MHz Function Generator HM8030-6 Valid at 23 C after a 30 minute warm-up period Operating modes Sine, square, triangle, pulse; free running, internal sweep or external frequency modulation, with or without DC offset Frequency ranges 0.05Hz
20、to 10MHz in 8 ranges, variable: x 0.09 to x 1.1 (12:1) Frequency drift:0.5%/hr or 0.8%/24hrs. at constant ambient temperature Waveform characteristics Sine wave distortion 0.05Hz to 1MHz:max. 0.5% 1MHz to 10MHz:max. 5% Square wave rise time:typ. 15ns Overshoot:5% (for termination into 50) Triangle n
21、on-linearity:1% (to 100kHz) Displays Frequency:5-digit, 7-segment LED, each 8 x 5mm Accuracy: up to 5Hz: (1% + 3 digits) 5Hz to 10MHz: (5x10-5+ 1 digit) LED indicators for mHz, Hz, kHz and sec Outputs Signal output:short-circuit proof, protected against ext. voltage up to 45VDCmax. (30sec.) Impedanc
22、e:50 Output voltage:10Vppinto 50 load; 20Vpp (open circuit) Attenuation:max. 60dB 2 attenuators:each 20dB 0.2dB Variable:0 to 20dB Amplitude error:(sine wave/triangle) 0.05Hz to 0.5MHz:max. 0.2dB 0.5MHz to 10MHz:max. 0.5dB DC offset:variable (on/off, except pulse function) into 50 load:max. 2.5V in
23、open circuit:max. 5V Trigger output:square wave synchronous to signal output, approx. +5V/TTL FM input (VCF, BNC connector on rear panel of HM8001-2 and option HO801) Frequency deviation:approx. 1 : 100 Input impedance:6k II25pF Input voltage:max. 30 V Internal sweep Sweep speed:20ms to 15s Sweep ra
24、nge:approx. 1:100 Miscellaneous Power supply+5V/200mA (from mainframe):+16V/300mA -16V/250mA (=9.8W). Operating temperature:+10C to +40C Max. relative humidity:80% (without condensation) Dimensions (W x H x D) (without 22-pole flat plug): 135 x 68 x 228mm Weight:approx. 0.80kg HM8030-6E/140705/ce Su
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Hameg hm8030 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf