Hameg hm303-6 电路图.pdf
《Hameg hm303-6 电路图.pdf》由会员分享,可在线阅读,更多相关《Hameg hm303-6 电路图.pdf(24页珍藏版)》请在收音机爱好者资料库上搜索。
1、O s c i l l o s c o p e H M 3 0 3 - 6 Manual English RadioFans.CN 收音机爱 好者资料库 Subject to change without notice 2 Contents General information regarding the CE marking . 4 General Information . 6 Symbols. 6 General Information . 6 Use of tilt handle . 6 Safety . 6 Intended purpose and operating condit
2、ions . 6 Warranty . 7 Maintenance. 7 Protective Switch-Off. 7 Power supply. 7 Type of signal voltage. 8 Amplitude Measurements . 8 Voltage values of a sine curve . 8 Total value of input voltage . 9 Time Measurements . 9 Connection of Test Signal . 10 First Time Operation . 11 Trace Rotation TR. 11
3、Probe compensation and use . 11 Adjustment at 1kHz. 11 Adjustment at 1MHz . 12 Operating modes of the vertical amplifiers . 12 X-Y Operation . 13 Phase comparison with Lissajous figures . 13 Phase difference measurement. 13 in DUAL mode . 13 Phase difference measurement in DUAL mode. 14 Measurement
4、of an amplitude modulation . 14 Triggering and time base . 14 Automatic Peak (value) - Triggering . 15 Normal Triggering. 15 Slope. 15 Trigger coupling. 15 Line triggering () . 16 Alternate triggering . 16 External triggering . 16 Trigger indicator . 16 Holdoff-time adjustment . 16 Component Tester.
5、 17 General . 17 Using the Component Tester. 17 Test Procedure . 17 Test Pattern Displays . 17 Testing Resistors . 17 Testing Capacitors and Inductors . 17 Testing Semiconductors . 18 Testing Diodes . 18 Testing Transistors . 18 In-Circuit Tests . 18 Front Panel Elements HM 303-6 (Brief Description
6、- Front View). 20 Short Instruction for HM303-6 . 22 Oscilloscope HM 303-6 3 RadioFans.CN 收音机爱 好者资料库 3 Subject to change without notice General information regarding the CE marking HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actu
7、al generic- and product stan- dards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility) the limits for industrial environment have been u
8、sed. The measuring- and data lines of the instrument have much infl uence on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or cables used may be different. For measurement operation the following hints and conditions regarding emissio
9、n and immunity should be observed: 1. Data cables For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently screened cables must be used. Without a special instruction in the manual for a reduced cable length, the maximum cable length
10、of a dataline must be less than 3 meters and not be used outside buildings. If an interface has several connectors only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-bus purposes the double screened cables HZ72S and HZ72L from HAME
11、G are suitable. 2. Signal cables Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings. Signal lines must scre
12、ened (coaxial cable - RG58/U). A proper ground connection is required. In combination with signal generators double screened cables (RG223/U, RG214/U) must be used. 3. Infl uence on measuring instruments. Under the presence of strong high frequency electric or magnetic fi elds, even with careful set
13、up of the measuring equipment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small deviations of the measuring value (reading) exceeding the instruments spe- cifi cations may result from such conditions in individual cases. 4. RF immu
14、nity of oscilloscopes. 4.1 Electromagnetic RF fi eld The infl uence of electric and magnetic RF fi elds may become visible (e.g. RF superimposed), if the fi eld intensity is high. In most cases the coupling into the oscilloscope takes place via the device under test, mains/line supply, test leads, c
15、ontrol cables and/or radiation. The device under test as well as the oscilloscope may be effected by such fi elds. Although the interior of the oscilloscope is screened by the cabinet, direct radiation can occur via the CRT gap. As the bandwidth of each amplifi er stage is higher than the total 3dB
16、bandwidth of the oscilloscope, the infl uence RF fi elds of even higher frequencies may be noticeable. 4.2 Electrical fast transients / electrostatic discharge Electrical fast transient signals (burst) may be coupled into the oscilloscope directly via the mains/line supply, or indirectly via test le
17、ads and/or control cables. Due to the high trigger and input sensitivity of the oscilloscopes, such normally high signals may effect the trigger unit and/or may become visible on the CRT, which is unavoidable. These effects can also be caused by direct or indirect electrostatic discharge. KONFORMITT
18、SERKLRUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE Hersteller HAMEG Instruments GmbH Manufacturer Industriestrae 6 Fabricant D-63533 Mainhausen Die HAMEG GmbH bescheinigt die Konformitt fr das Produkt The HAMEG GmbH herewith declares conformity of the product HAMEG GmbH dclare la conformi
19、te du produit Bezeichnung / Product name / Designation: Oszilloskop/Oscilloscope/Oscilloscope Typ / Type / Type: HM303-6 mit / with / avec: Optionen / Options / Options: mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes EMV Richtlinie 89/336/EWG ergnzt durc
20、h 91/263/EWG, 92/31/EWG EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC Directive EMC 89/336/CEE amende par 91/263/EWG, 92/31/CEE Niederspannungsrichtlinie 73/23/EWG ergnzt durch 93/68/EWG Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC Directive des equipements basse tensio
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Hameg hm303-6 电路图 hm303
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf