ifr2026q 电路图.pdf
《ifr2026q 电路图.pdf》由会员分享,可在线阅读,更多相关《ifr2026q 电路图.pdf(8页珍藏版)》请在收音机爱好者资料库上搜索。
1、a d v a n c i n g w i r e l e s s t e s t The 2026Q is designed to work with a radio test set to provide a fully integrated radio receiver test solution for cellular and PCS systems Signal Sources 2026Q CDMA/GSM Interferer MultiSource Generator Two tone interference generation for AMPS/CDMA receiver
2、 testing in accordance with IS-97-A/IS-98-A Option for providing GSM signals for receiver and amplifier testing Combiner output frequency range from 800 MHz to 2.0 GHz Provides single calibrated point of reference for the transceiver under test Excellent phase noise and spectral purity Elimination o
3、f additional RF combining or signal conditioning High internal isolation of returned signals Includes two independent, fully featured RF signal generators 10 kHz to 2.4 GHz Very low levels of internally generated intermodulation products Single unit solution for CDMA interference testing The 2026Q i
4、s a derivative of the popular 2026 MultiSource RF signal generator. It has been designed to work directly with a CDMA radio test set to produce a fully integrated radio receiver test solution for CDMA cellular and PCS systems in accordance with IS-97-A/IS-98-A. Calibrated and Combined Signal Path It
5、 is designed to produce a fully calibrated combined RF output containing any mix of internally generated interference signals from its two RF sources, together with a calibrated signal path for a radio test set transmit output. A return path from the transceiver back to the radio test set receiver i
6、nput is also provided through the instrument as illustrated in figure 1. This allows a CDMA receiver to be tested for sensitivity in the presence of single or dual tone interference. The interfering signals are combined without the need for any RF switching mechanism that would otherwise affect the
7、test result. Option 116 allows the 2026Q to provide GSM modulated signals for receiver or amplifier testing with low floor noise characteristics. High Isolation 2026Q is configured to ensure high levels of isolation between each of the transmit and receive paths between the radio test set, the inter
8、fering signal sources and the transceiver under test. Figure 1 : 2026Q configured for radio testing with a test set Path loss test data is supplied with each instrument for the frequency bands 865 MHz - 895 MHz, 1750 MHz - 1990 MHz. Drift influences within these bands is minimal ensuring a level acc
9、uracy of better than 0.75 dB. The RadioFans.CN 收音机爱 好者资料库 frequency response across each of these bands is flat to within 0.1 dB, thus minimizing the need for additional system calibration. Independent Signal Generators Each of the RF generators contained within 2026Q may be used independently, rout
10、ed to their individual RF connectors. In this mode, each generator covers the full frequency range 10 kHz to 2.4 GHz with an output power of between -137 dBm and +24 dBm. Each source may be independently modulated either from an internal or external source(s). Modulation modes include AM, FM, PM, Pu
11、lse and 2/4 level FSK. The standard 2026 specification applies when used in this mode. Excellent Spectral Purity Very low phase noise and spurious responses are achieved making them ideal for CDMA handset interference tests and other general purpose applications. The 2026Q has a low residual FM of t
12、ypically 3 Hz and typical sideband noise of -121 dBc/Hz at 20 kHz offset from 1 GHz. The excellent noise floor performance is more than adequate for mobile handset and base station testing. Typical SSB Phase Noise at 1 GHz Typical Phase Noise at 20 kHz offset Flexible Source Routing Each of the sign
13、al sources can either be routed to a separate output connector or switched to the input of an RF combiner network before being fed to the combiner output connector. The combiner routing is set up quickly and effectively using the Combiner Set Up menu. Setting up the source and combiner routing The f
14、lexibility of the signal routing allows the 2026Q to accept an external input from another signal generator, such as the 2050 Digital and Vector Generator producing CDMA modulation or a radio test set. Automatic Source Coupling The two internal generators can have their frequency and level coupled.
15、In the case of RF level this coupling can be any fixed offset enabling control of a single parameter to manifest a change in both sources. For RF frequency this coupling can be both a fixed frequency offset or a harmonically related offset and again allow simple programming and control of the instru
16、ment. Setting up coupling Sweep The 2026Q allows either of the independent RF sources to be frequency swept with user defined start, stop, and step values to reduce the amount of operator time or GPIB overhead. By enabling the coupling facility, sweeping one source will simultaneously sweep the othe
17、r internal RF source to allow automated swept measurements on frequency conversion devices to be made. High RF Output Each of the RF signal generators is able to deliver up to +24 dBm at their output, making them ideal for testing components such as mixers and amplifiers etc. Comprehensive Modulatio
18、n Each signal source is capable of being independently modulated from its own fully programmable modulation source to ensure maximum flexibility. The internal modulation sources are each capable of generating sine, triangle or square wave signals. Amplitude, frequency and phase modulated carriers ca
19、n be generated from the internal modulation sources or from the a d v a n c i n g w i r e l e s s t e s t RadioFans.CN 收音机爱 好者资料库 independent external inputs. The frequency modulation system provides excellent performance in the DC coupled mode with very low carrier frequency error and stability ens
20、uring that the generator can accurately test receivers sensitive to small frequency errors. Programming A GPIB interface is fitted so that all standard signal generator functions are controllable over the bus. The protocol and syntax of GPIB commands has been designed in accordance with IEEE 488.2 s
21、tandard to facilitate the generation of ATE programs. A RS-232 interface is fitted as standard with a common command set to GPIB commands. RS-232 control is particularly suitable for use with simple external controllers or RF modems when the instrument is being used in a remote location. Low Cost of
22、 Ownership An electronic trip protects the individual source outputs against the accidental application of reverse power. Careful attention to the thermal design and the use of well-proven signal generator modules gives high reliability and calibration validity. The use of flash memory and software
23、download via the RS-232 interface means the 2026Q can be upgraded with its covers fitted. Option 116 - GSM Modulation Option 116 is avaialble to allow 2026A/B to emulate GSM signals using FM techniques which achieves superior noise floor performance than solutions using IQ systems. The facility is i
24、deal for testing GSM receiver selectivity and for testing the linearity of high performance multi-carrier power amplifiers. Specification General Description The 2026Q CDMA Interferer MultiSource Generator is a purpose built instrument for testing CDMA hand-set and base station equipment. It feature
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ifr2026q 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf