1、PN 942615 March 1995 1995 Fluke Corporation, Inc. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. 2640A/2645A NetDAQ Data Acquisition Tools Service Manual RadioFans.CN 收音机爱 好者资料库 LIMITED WARRANTY the 150V value is for all other channels. 2 Drift
2、 Correction refers to an automatic internal measurement step performed with each scan to correct for drift due to changes in ambient temperature and humidity. Table 1-2. Summary of 2640A/2645A Measurement Capabilities Capability2640A2645A Volts DC MeasurementsRanges: 90 mV 300 mV 3V 30V 150/300V 1 A
3、utorange Ranges: 90 mV 300 mV 3V 30V 50V Autorange Volts AC MeasurementsRanges: 300 mV 3V 30V 150/300V 1 Autorange Ranges: 300 mV 3V 30V Autorange Resistance MeasurementsRanges: 300 3 k 30 k 300 k 3 M Autorange Ranges: 30 k 300 k 3 M Autorange Introduction and Specification Introduction1 1-5 Table 1
4、-2. Summary of 2640A/2645A Measurement Capabilities (cont) Capability2640A2645A Temperature Measurements (Thermocouple) 2 Thermocouples: JKRSE TBCN Thermocouples: JKRSE TBCN Temperature Measurements (RTD) (Two-wire) RTD R0:10 to 1010(None) Temperature Measurements (RTD) (Four-wire) RTD R0:10 to 1010
5、RTD R0:10 to 1010 Frequency Measurements 3Ranges:AutorangeRanges:Autorange Amperes DC Measurements 4Ranges:4 to 20 mA 0 to 100 mA Ranges:4 to 20 mA 0 to 100 mA 1 300V range available only on channels 1 and 11. 2 Open thermocouple detection is supported on a per-channel basis. 3 Minimum frequency is
6、20 Hz. Signal strength must be at least 50 mV ac rms. 4 Shunt resistor required (enter value; default is 10 ohms). The 4 to 20 mA scale displayed as 0% (4 mA) to 100% (20 mA). Table 1-3. Summary of 2640A/2645A Features FeatureDescription Analog Channels20 (channels 1 to 20) Computed Channels10 (chan
7、nels 21 to 30) Alarm LimitsTwo per channel Mx+B ScalingAny configured channel (1 to 30) Scan TriggeringInterval/External/Alarm Trigger Channel MonitoringAny configured channel, scanning or not scanning Setup and OperationVia host computer Communications PortsEthernet 10BASE2 and 10BASE-T Primary Pow
8、erAC - 107 to 264V ac, 50/60 Hz DC - 9 to 16V dc Nonvolatile Memory (unaffected by cycling instrument power) Instrument parameters: Base Channel Number, Line Frequency, Network Type, Socket Port, IP Address, Baud Rate. (See Chapter 2.) Permanent Data StorageVia host computer Real-Time Trend Plotting
9、Via host computer NetDAQ Service Manual 1-6 Options and Accessories1-2. Table 1-4 summarizes the available models, options and accessories, including measurement transducers, software, connector sets, Ethernet interfaces, cables, and components. Table 1-4. Models, Options and Accessories ModelDescri
10、ption 2640ANetDAQ Instrument 2645ANetDAQ Instrument 264XA-901NetDAQ Logger for Windows (Isolated Network) 264XA-902NetDAQ Logger for Windows (General Network) 264XA-902UNetDAQ Logger for Windows Network (Upgrade Kit) 264XA-801Ethernet Card 264XA-802Parallel-to-LAN Adapter (10BASE2) 80i-410Clamp-On D
11、C/AC Current Probe 80i-1010Clamp-On DC/AC Current Probe 2620A-100I/O connector set, including Universal Input Module, DIGITAL I/O and ALARM/TRIGGER I/O connectors. 2620A-1014-20 mA Current Shunt Strip 942615NetDAQ Service Manual Y264119-inch Rackmount Kit Y26434-meter Cable Kit Instrument Connector
12、Set, 2620A-1001-3. The 2620A-100 is a complete set of input connectors: one Universal Input Module, one ALARM/TRIGGER I/O connector, and one DIGITAL I/O connector. Each instrument comes with a 2620A-100 Instrument Connector Set. The use of additional connector sets allows quick equipment interface t
13、o several wiring setups. Host Computer Ethernet Interfaces1-4. The 264XA-801 is the recommended Ethernet card and the 264XA-802 is the recommended Parallel-to-LAN Adapter for host computer installations. Interconnection Cables and Components1-5. Cables for equipment interconnection can be purchased
14、as an option or fabricated. Ethernet interconnection components such as BNC T and 50-ohm terminations are available from any components supplier. Introduction and Specification Operating Instructions1 1-7 Operating Instructions1-6. Full operating instructions are provided in the NetDAQ User Manual (
15、PN 942623). Refer to the User Manual as necessary during the maintenance and repair procedures presented in this Service Manual. Organization of the Service Manual1-7. This manual focuses on performance tests, calibration procedures, and component-level repair of the 2640A and 2645A networked data a
16、cquisition units. To that end, manual chapters are often interdependent; effective troubleshooting may require not only reference to the troubleshooting procedures in Chapter 5, but also some understanding of the detailed Theory of Operation in Chapter 2 and some tracing of circuit operation in the
17、Schematic Diagrams presented in Chapter 7. Often, scanning the table of contents yields an appropriate place to start using the manual. A comprehensive table of contents is presented at the front of the manual; local tables of contents are also presented at the beginning of each chapter for ease of
18、reference. If you know the topic name, the index at the end of the manual is probably a good place to start. The following descriptions introduce the manual: Chapter 1 - Introduction and Specifications Introduces the instrument, describing its features, options, and accessories. This chapter also di
19、scusses use of the Service Manual and the various conventions used in describing the circuitry. Finally, a complete set of specifications is presented. Chapter 2 - Theory of Operation This chapter first categorizes the instruments circuitry into functional blocks, with a description of each blocks r
20、ole in overall operation. A detailed circuit description is then given for each block. These descriptions explore operation to the component level and fully support troubleshooting procedures defined in Chapter 5. Chapter 3 - General Maintenance Provides maintenance information covering handling, cl
21、eaning, and fuse replacement. Access and reassembly procedures are also explained in this chapter. Chapter 4 - Performance Testing and Calibration This chapter provides performance verification procedures, which relate to the specifications presented in Chapter 1. To maintain these specifications, a
22、 full calibration procedure is also presented. Chapter 5 - Diagnostic Testing and Troubleshooting The troubleshooting procedures presented in this chapter rely closely on both the Theory of Operation presented in Chapter 2, the Schematic Diagrams shown in Chapter 7, and the access information provid
23、ed in Chapter 3. Chapter 6 - List of Replaceable Parts Includes parts lists for all standard assemblies. Information on how and where to order parts is also provided. Chapter 7 - Schematic Diagrams Includes schematic Diagrams for all standard and optional assemblies. A list of mnemonic definitions i
24、s also included to aid in identifying signal name abbreviations. NetDAQ Service Manual 1-8 Conventions1-8. Throughout the manual set, certain notational conventions are used. A summary of these conventions follows: Instrument Reference The term instrument is used in this manual to refer to both the