KEI 707 Quick Reference Guide 电路图.pdf
《KEI 707 Quick Reference Guide 电路图.pdf》由会员分享,可在线阅读,更多相关《KEI 707 Quick Reference Guide 电路图.pdf(64页珍藏版)》请在收音机爱好者资料库上搜索。
1、MODEL 707 SWITCHING MATRIX QUICK REFERENCE GUIDE RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 INTRODUCTION This quick reference guide cOntai”S deScripfio”S Of Various features and information concerning the operation of the Model 707. Also included are programming examples using “alio”S controlle
2、rs. 01988, Keithley Instruments, 1C. Instruments Division Cleveland. Ohio, U.S.A. Document Number: 707-903-01 Rev. A RadioFans.CN 收音机爱 好者资料库 TABLE OF CONTENTS SAFETYPRECAUTIONS . 2 FRONT PANEL FAMlLlARlZATlON . 3 OlSPLAY MESSAGES, . 18 REAR PANEL FAM,L,ARlZATlON. . 20 ,NSTALL,NG AND REMOVING CARDS .
3、 25 MASTER,SLA”E SYSTEMS . 27 BASIC SWITCHING OPERATION. . 30 Selectins Make/Break and Break/Make Rows 31 Modifyilg a Relay Setup . storing Setup and Sending to Relays . IEEE-488 PROGRAMMING . Device-Dependent Commands . oata Formats . Hit Key Commands . SRO Mask and Serial Poll Byte . staws Words.
4、. PROGRAMS ,.,.,. IBM PC/XT/AT with CEC PC 488 IBM PC,XT,AT with CEC PC ,488 and ASYST HP Mode, 9000 series 200,3OO. 57 SAFETY PRECAUTIONS 2. Inspect the connecting cables and test leads for possi ble wear, cracks, or breaks before each use. 3. For maximum safety. do not touch the test cables or any
5、 iktrumenfs while power is applied to the circuit under test. Turn off the power and discharge any capacitors before connecting or disconnecting cables from rhe InmiX car*. 5. Da not exceed the maximum allowable input of the matrix cards. as defined in the specifications and operas tion sections of
6、their manual. 2 FRONT PANEL FAMILIARIZATION POWER AC power switch turm the unit on or off, 3 CROSSPOINT DISPLAY GROUP MEMORY-Displays a stared relay setup (from location shown in MEMORY STEP field) on the crosspoint display and lights the MEMORY indicator. RELAYlOisplays the current relay setup an t
7、he crosspoint display and lights the RELAYS indicator. CROSSPOINT DISPLAY MODIFIED-Lights when changes are made to the crosspaint display (by front panel keys or light pen), making if different from the original configuration. COPY DISPLAY-MEMORY-Capies the displayed cross- point configuration to th
8、e location shown in the MEMORY STEP field. 4 COPY DISPLAY-RELAYS-Copies the displayed crosspoint configuration to the relays. AUTOMATIC (COPY DISPLAY-RELAYS)-When this LED is lit. any change to the crosspoint display is sent to the relays at the same time. The pushbutton toggles the LED on and off.
9、ITo affect chanae in memarv, displav must be copied to memory. SCROLL GROUP SCROLL A-If MEMORY indicator is lit, increments MEMORY STEP field and displays setup on crosspoint LEDs. If RELAYS indicator is lit. increments RELAY STEP field, displays setup on crosspoint LEDs, and sends setup to relays.
10、Also used for scrolling up through a list of multiple choice parameters. SCROLL .-Same actions as the SCROLL A key except that if decrements and SCrdS down. INSERT-Inserts a blank serup at the location shown in the MEMORY STEP Field. Moves higher stored setups up one memory location. DELETE-Deletes
11、the setup at the locafion shown in the MEMORY STEP field. Moves higher stored setups down one memory location. MENU r MEN” 0 00 I Message EXT TRIG FALL EXT TRIG RISE MATRIX RDY LO MATRIX RDY HI STANDALONE MASTER IEEE-488 nn HWSETL nnn mS n cccc SELF TEST FACTORY NIT I Item Description I view digital
12、 input. program digital output. Select which edge of external trigger pulse triggers Model 707 (falling or rising). Select matrix ready output level (active LO or HI). Select stand-alone OI master, l.we operation. Program IEEE-488 bus address. View longest relay Ihardware) settling time of cards in
13、system. View slot number Ini and card label tcccc,. EYeCUte Self test. Return to factory defaults. ,All stored SetUpS a,0 cleared., Programmable parameters can be changed with the SCROLL or data entry keys and then pressing ENTER. 7 SETTLING TIME-Displays the current value of programmed settling tim
14、e. (This delay begins after the relay seftling time.1 To change the value. enter between 0.65000msec and press ENTER. MAKE/BREAK-Selects rows to operate as make/break (make-before-break) for all setups. First enter row desigrw fion IA-H), then press MAKE/BREAK fo roggle the state for that row and im
15、mediately reprogram the Model 707 for the new operation. BREAK/MAKE-Same action 8s MAKE/BREAK except that it selects break/make (break-before-make) rows. ISelecting a row for break/make de-selects it for make/break and vice versa.) 8 LOCAL When in remote WEMOTE on). return the Model 707 to local mad
16、e (REMOTE off). If restores operation of other front panel onfrols unless LLO llocal Lockout) is in effect TRIGGER GROUP ENABLE-Toggles between triggers enabled and triggers disabled. When triggers are enabled. the LED is lit. SOURCEPDisplays current trigger source. Use SCROLL keys 20 display source
17、s, then press ENTER to select the desired source: TRIG ON TALK IEEE-488 talk command TRIG ON GET - IEEE-488 GET command TRIG ON X - IEEE-488 X command TRlG ON EXT - External trigger pulse (rear panel input) TRIG ON KEY -Front panel MANUAL key only MANUAL-Generates a trigger from front panel if trigg
18、ers are enabled (no matter which trigger source is selectedl. If the trigger source is TRIG ON KEY. only the MANUAL key generates a trigger DATA ENTRY ASH, O-S-These keys are for entering row/column addresses and setup locations, selecting make/break and break/make rows, and entering various numeric
19、 values. CANCEL-If the value in the alphanumeric display has been modified, this key restores the currenf parameter value. If the velue in the alphanumeric display has not been modified, this key returns the Model 707 to the previous display. CANCEL also exits from menu mode if no changes have been
20、made. ENTER-If the value in the alphanumeric display has been modified, pressing this key stores the parameter value. Also invokes immediate action items from the menu and exits menu mode (except when digital 110 is displaYedI RESET LI: Performs the same functions as cycling power Call relays are op
21、ened. triggers are disabled. RELAY STEP to 000, MEMORY STEP fo 001, etc.). except powerup self-checking and masterislave loop initieliration. CLEAR, OPEN, CLOSE CLEAR-Turns Off a, crosspoint display LEO% If the AUTOMATIC ICOPY DISPLAY-RELAYS) indicator is lip. all relays are opened immediately. OPEN
22、 -Turns off rcmpoint LED of row,column shown on alphanumeric display. If the AUTOMATIC (COPY DISPLAY- RELAYSI indicator is lit. the corresponding relay opens immediately CLOSESame action as OPEN key except that it turns on the crosspoint LED and relay. ALPHANUMERIC DISPLAY pziizzs A Wcharacter displ
23、ay that can show: . Error messages. l Menu item selections. . Last setup sent from memory to the relays (RELAY STEP field,. IEEE-488 STATUS INDICATORS These three LED indicators apply to instrument operation over the IEEE-488 bus. The TALK and LISTEN indicators show when fhe unit has been addressed
24、to talk or listen. REMOTE turns on to show when the unit is in the IEEE-488 remote State. CROSSPOINT DISPLAY LEDs Show open and closed crosspoinrs of the CUllem relay setup, a stored relay setup, or an edited relay setup. Each LED block of 8 rows by 12 columns shows on/off states of one card. States