1、Model 7076 General Purpose Matrix Card Dual 4 x 12 Instruction Manual Contains Operating and Servicing Information Publication Date: April 1991 Document Number: 7076-901-01 Rev. B RadioFans.CN 收音机爱 好者资料库 WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material an
2、d workmanship for a period of 1 year from date of shipment. Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries, diskettes, and documentation. During the warranty period, we will, at our option, either repair or replac
3、e any product that prows to be defective To exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service f
4、acility. Repairs will be made and the product returned, transportation prepaid. Repaired or replaced products are warranted for the balance of the origi- nal warranty period, or at least 90 days. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from product modification witho
5、ut Keithleys express written consent, or misuse of any product ot part. This warranty also does not apply to fuses, software. non-rechargeable batteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANT
6、IES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THE REMEDIES PROVIDED HEREIN ARE BUYERS SOLE AND EXCLUSIVE REMEDIES. NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDI- RECT, SPECIAL, INCIDENT
7、AL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS INSTRUMENTS AND SOFTWARE EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIMITED TO: COSTS OF REMOVAL AND INSTALLATION, LOSSES SUSTAINED AS T
8、HE RESULT OF INJURY TO ANY PERSON, OR DAMAGE TO PROPERTY. Keithley Instruments, Inc. * 28775 Aurora Road * Cleveland, OH 44139 - 216-248-0400 -Fax: 216-248-6168 - RadioFans.CN 收音机爱 好者资料库 General Purpose Matrix Card Dual 4 x 12 Model 7076 Instruction Manual 01990, Keithley Instruments, Inc. All right
9、s reserved. Cleveland, Ohio, U. S. A. Document Number: 7076-901-01 RadioFans.CN 收音机爱 好者资料库 All Keithley product names are trademarks or registered trademarks of Keithky Instruments, Inc. Other brand and product names are trademarks or registered trademarks of their respective holders SAFETY PRECAUTI
10、ONS The following safety precautions should be observed before using the Model 7076 and the associated instruments. This matrix card is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read over this m
11、anual carefully before using the matrix card. ALWAYS remove power from the entire system (Model 707, test instruments, DUT, etc.) and discharge any capacitors before doing any of the following: 1. Installing or removing the matrix card from the mainframe. 2. Connecting or disconnecting cables from t
12、he matrix card. The pins of cable connectors are easily accessible making them extremely hazardous to handle while power is applied. 3. Making internal changes to the card (such as removing or installing jumpers). Exercise extreme caution when a shock hazard is present at the test f?xture. User-supp
13、lied lethal voltages may be present on the tlxture or the connector jacks. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30V RMS or42.4V peak are present. A good safety practice is to expect that hazardous voltage is present in an
14、y unknown circuit before measuring. Do not connect the card or any other instrumentation to humans. Inspect the connecting cables and test leads for possible wear, cracks, or breaks before each use. For maximum safety, do not touch the test fixture, test cables or any instruments while power is appl
15、ied to the circuit under test. Do not touch any object which could provide a current path to the common side of the circuit under test or power line (earth) ground. Do not exceed the maximum signal levels of the test fixture, as defined in the specifications and operation section of this manual. Do
16、not connect the matrix card directly to unlimited power circuits. This product is intended to be used with impedance limited sources. NEVER connect the matrix card directly to ac mains. When connecting sources, install protective devices to limit fault current and voltage to the card. The chassis co
17、nnections must only be used as shield connections for measuring circuits, NOT as safety earth ground connections. Model 7076 Dual 4x12 Two-Pole Matrix Card MATRIXCON”GURATION:Dual4rowsby12columns.Alsocanfigurableas8rowsby 12 mhmns. Jumpers can be removed to isolate any row from the backplane. CROSSP
18、OINT CONFIGURATION: 2 pole Form A (HI, GUARD). CONNECTOR TYPE: 25.pin subminiature D connector, two for column connection, one far row connection. MAXIMUM SIGNAL LEVEL: DC Signals: IIOV DC, IA switched, 30VA ksistive load). AC Signals: 175” AC peak, IA switched, 62SVA (resistive load). COMMON MODE V
19、OLTAGE: IIOV DC, 175V AC peak pin to pi” or pi” to chassi% CONTACT LIFE: Cold Switching: 10s closures. At M.Mm”rn Signal Level: 105 closures. PATH RESISTANCE (per conductorb 0.5On initial, 1.5R at end of contact life CONTACTPOTENTIAL: 5pV per crosspaint (HI lo GUARD). OFFSET CURRENT: lOw2, lOQ l2opF
20、 nominal. Common Mode: lOQ 2OOpFnominal. CROSSTALK (IMHr, Mfi 1o;db -5OdB. INSERTION LOSS (IMHz, 5On source, 5OR load): 0.05dB typical. 3dB BANDWIDTH (500 load): 15MHz typical. RELAY DRIVE CURRENT (per crosspoint): 28mA. RELAY SEITLING TIME: 3ms. ENVIRONMENT: Operating: 0 to 5O”C, up to 35C at 70% R
21、.H. storage: -250 to WC. ACCESSORY SUPPLIED: instruction manual, jumpers for 8 x 12 expansion. 5pcifications subject to change without notice. Column Jumpers - (user Table of Contents SECTION 1 - General Information 1.1 INTRODUCTION 1.2 FEATURES . 1.3 WARRANTY INFORMATION 1.4 MANUAL ADDENDA 1.5 SAFE
22、TY SYMBOLS AND TERMS 1.6 SPECIFICATIONS . . 1.7 UNPACKING AND INSPECTION 1.7.1 Inspection for Damage . . . 1.7.2 Shipping Contents 1.7.3 Instruction Manual 1.8 REPACKING FOR SHIPMENT 1.9 OPTIONAL ACCESSORIES SECTION 2 - Operation 2.1 INTRODUCTION . 2.2 HANDLING PRECAUTIONS . 2.3 CARD INSTALLATION AN
23、D REMOVAL . 2.4 BASIC MATRIX CONFIGURATIONS . 2.4.1 4x24Matrix . 2.4.2 8xl2Matrix . 2.5 TYPICAL MATRIX SWITCHING SCHEMES . 2.5.1 Single-ended Switching. . 2.5.2 Differential Switching . 2.5.3 Guarding . 2.5.4 Sensing . 2.6 CONNECTIONS . 2.6.1 Standard Cable (Model 7075-MTC) . 2.6.2 High Isolation Ca
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- KEI 7076 Instruction 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf