KEI32430A(Model179A) 电路图.pdf
《KEI32430A(Model179A) 电路图.pdf》由会员分享,可在线阅读,更多相关《KEI32430A(Model179A) 电路图.pdf(33页珍藏版)》请在收音机爱好者资料库上搜索。
1、Instruction Manual Model 179A TRMS Multimeter 01982, Keithley Instruments, Inc. Cleveland, Ohio, U.S.A. Document Number 32430 RadioFans.CN 收音机爱 好者资料库 SPECIFICATIONS DC AND TRMS AC AMPS 20 A A 0.5%+2d* l%+lEdt 0.5” ,Ornll *Add 0.1 %rdg above 15A fo, self-testing. tlktir max. MAXIMUM INPUT: 24 250” DC
2、 o, rms (fuse protected, except or 20A range: l5A continuous. 20A for 1 minute lunfusedl. TEMPERATTURE COEFFlClENT OF-18C Et 28-!XioC,: DC f,O.Ol% +O.Zd,T. AC * lO.O7% +2dlPC. CREST FACTOR Iratio of peak value to rms valuel: 31. SETTLING TIME: DC: 1 second to within 1 digit of final reading. AC: 2 s
3、econds to within 15 digits of final reading. MAXIMUM OPEN CIRCUIT VOLTAGE: 5” GENERAL DISPLAY: Five 0.5” LED digits. appropriate decimal position and polarity indication. CONVERSION PERIOD: 4OOms. OVERRANGE INDICATION: Display blinks all zmoes above 19999 counts. MAXIMVM COMMON MODE VOLTAGE: ,400” o
4、eak. EWI,R,ONMENT: Operating: 0 0 -55C. 0% to 80% relative humidity up c. storage: -25T to +l35oc. POWER : 105-125” 0, 210-250” bvitch selectedl. go-,lO” available. 5060 Hz, 5.5w. Optional B-hour batmy pack. Model 1788. DIMENSIONS. n IEIGHT: 85mm high x 235mm wide x 275mm deco 13%” x 9%” x WY,“,. Ne
5、tweigirt l.Skg 14 Ix). ACCESSORIES SUPPLIED: ,nst,wtio” Manual md Mode, ,691 Tesf Leads. ACCESSORIES AVAILASLE: Model 1010: Single Rack Mounting Kit Model 1017: Dual Rack Mounting Kit Model 1301: Temperature Probe Model 1600A: High Voltage Probe ,4Ok”, Model 1651: 50.Ampere Current Shunt Model 1581:
6、 Clip-On Test Lead Set Model ISSZA: RF Probe Model 1683: Universal Test Lead Kit Model 1584: Herd She, Carwing Case Model ,885: Clamp-On AC Probe Model 1591: General Purpass Test Lead Set Model 1788: Rechargeable Smtery Pack Model 1792: Isolated SCD Output Model 1793: isolated IEEE-488 O”f,uf Model
7、7008-3: IEEE488 Cable (3 ft.1 Model 7008-6: IEEE-488 Cable 18 tt., RadioFans.CN 收音机爱 好者资料库 TABLE OF CONTENTS PARAGRAPH TITLE PAGE 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 SECTION 1 GENERAL INFORMATION Introduction. . . Features . Warranty Information . . . ManualAddenda. . Safety Symbols and Terms . Unpackin
8、g and Inspection . . , . . . . Optional Accessories . Specifications . , . . . . 4.4 4.5 4.5.1 4.5.2 4.6 4.6.1 4.6.2 4.6.3 4.6.4 4.7 4.8 4.9 4.10 2.1 2.1.1 2.1.2 2.1.3 2.2 2.2.1 2.2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 4.1 4.2 4.2.1 4.2.2 4.2.3 4.3 4.3.1 4.3.2
9、 SECTION 2 OPERATION Preparation for Use., . . . LinePower. . Battery Pack Power . . Battery Charging . . . . Operating lnsfructi”ns . , . . Environmental Conditions . . , . Front Panel Familiarization . . . DMMMeasurements . DC Voltage Measurement . . . . TRMS AC Voltage Measurement . . . . Resista
10、nce (111 Measurement . . Current Measurement IDC or TRMS ACI . . AC and DC Measurement . . . . . SECTION 3 PERFORMANCE VERIFICATION Introduction. . . . . . Environmental Conditions . . . . Recommended Test Equipment . . . PerformanceVerification Procedure . . . Initial Conditions . , . . . . . DCVol
11、tsVerification . AC Volts Verification . . . . Resistance Verification. . . DC Current Verification . , . . . AC Current Verification . . . . . SECTION 4 THEORY OF OPERATION Introduction., . . , . . Overall Operation . . . Signal Conditianing . . . . . . Ohms Cowersian . . . . . A/D Converter . . .
12、. . Attenuation . DC”o,ts. . AC”“,ts. . 21 21 2-l 2-1 21 2-1 21 2-3 2-3 24 2-4 24 25 3-1 31 3-1 31 31 31 3-2 3-2 3-2 3-2 4-1 41 41 4-1 4 1 42 42 42 . 42 42 4-2 42 43 4-3 43 4-3 4-3 44 4-4 5.1 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.3 5.4 5.4.1 5.5 5.6 5.7 6.1 6.2 6.3 6.4 6.5 6.6 SECTION 5 MAINTENANCE Introduc
13、tion., , Calibration Procedure Rccommendcd Tesr Equipment Environmental Canditions Calibration Shield Installation Calibration Adjustments Batten/ Pack iModel 17881 installation Troubleshooting . . Troubleshooting Procedure Special Handling of Static Sen 1200V peak, for lo seconds per minute. 1200V
14、peak. 1OOOV rms; 1400V peak; 107WHz. 2A, 250V DC or rms (fuse protected) 15A continuous, 20A for 1 minute (50% duty cycle1 450V rms sine wave; 1OOOV peak, for lo seconds per minute. Figure 2-4. AC Voltage Measurement 2.3.3 Resistance III) Measurement 1. Select the 12 function. 1. For current measure
15、ments up to 20OOmA: A. Select the ACA or DCA function, B. Select the desired range (up to 2000mA). C. Connect the unknown current to the INPUT jacks of 2. Select the HI mode or the LO mode (see paragraph 2.2.2 the Model 179A as shown in Figure 2-6. SteD 31. D. Note reading on display. Figure 2-5. Re
16、sistance InI Measurement 2.3.4 Current Measurement IDC or TRMS AC) NOTE To prevent measurement errors, connect the current test leads to either the 20A jacks or the normal INPUT jacks. Disconnect all cir- cuits from the unused jacks. WARNING To prevent electrical shock, remove power from the circuit
17、 to be measured before connecting the Model 179A. 3. Connect the unknown resistance (RI to the INPUT jacks 2. FW current measurements between 2000mA and 20A: of the 179A as shown in Figure 2-5. A. Select the ACA or DCA function. 4. Note reading on display. B. Depress the 20A range switch. C. Connect
18、 the unknown current to the 20 AMP jacks of the Model 179A as shown in Figure 2.7. D. Note the reading on display. 2-4 Figure 2-6. Current Measurements up to 2006mA NOTE Up to 15A may be applied continuously without degradation of the measurement due to self-heating effects. For currents be- tween 1
19、5A and 20A. specified accuracy can only be obtained when measurements are limited to a 50% duty cycle (i.e., apply the current for a maximum of one minute and then allow et least one minute for cooling before the next measurement). NOTE The test leads used must be capable of handling 20A and it is r
20、ecommended that they be twisted (see Figure 2-71 to minimize external fields which could affect the Model 179A or other equipment. Also, keep the test leads as short es possible to mlnlmlze voltage drop. Figure 2-7. Current Measurements Between 2000mA and 20A 2.3.5 AC + DC Measurement Use the Model
21、179A to meawre TRMS on ;I sigrw WIWII has both AC and DC components as lollows: 1. Measure and record the TRMS AC cononent as described in paragraph 2.3.2. 2. Measure and record the DC component as descritxxl III paragraph 2.3.1. 3. Compute the rms value from the followim e(/uaton ERMs im 2-512-6 SE
22、CTION 3 PERFORMANCE VERIFICATION 3.1 INTRODUCTION Performance verification may be done upon receipt of the instrument to ensure that no damage or misadjustment has occurred during transit. Verification may also be performed whenever there is question of the instruments accuracy and following calibra
23、tion if desired. NOTE For instruments that are still under warranty (less than 12 months since date of shipment), whose performance falls outside specifications at any point, contact your Keithley representative or the factory imp mediately. 3.2 ENVIRONMENTAL CONDITIONS Measurements should be made a