KEI28039I(Model616) 电路图.pdf
《KEI28039I(Model616) 电路图.pdf》由会员分享,可在线阅读,更多相关《KEI28039I(Model616) 电路图.pdf(79页珍藏版)》请在收音机爱好者资料库上搜索。
1、INSTRUCTION MANUAL Digital Electrometer Model 616 COPYRIGHT 1975 KEITHLEY INSTRUMENTS, INC. NINTH PRINTING, FEBRUARY, 1980, CLEVELAND, OHIO, U. S. A. DOCUMENT NO. 28039 RadioFans.CN 收音机爱 好者资料库 COWENTS CONTENTS Section Page SpECIFIC*TIONS - i” 1. GENW*tci seetinp Accuracy 103 to lob fuli range in a d
2、ecade ranges. 100% overranging to 1999 on all ranges. ACCURACY (20C to 3OC): (5% of reading +O.l% of range) 0 a11 ranges. 1 AS A CONSTANT CURRENT SOURCE RANGE: 8 CurrentS in decade seeps from 10-5 fo lo-12 ampere using OHMS ranges. Hi eermina1 is positive. COmJLIANCE: up to 200 volts. ACCURACY (ZOC
3、eo 3OC): 20.5% from 10-5 eo lo-7 ampere. *2% at 10-a ampere. ?5% from 10-9 to 10-12 ampere. LOAD REGULATION: 1011 ohms. Better than 0.1% for loads up to GENERAL DISPLAY: 3 digits plus 1 overrange digit; decimal position, polarity, and overload indicaeio; 5 readings per second. Depending on sensitivi
4、ey setting, 3 least-siificant digits blink or blaok he overload condition exists. POLARITY SELECTION: Automatic SENSITIVITY SELECTION: Automatic: Voltage sensi- tivity selection is fully sutomstic. sensieiviey selection is aWma?Lc hlo decades above and be- low range switch setting for resistance, ch
5、arge, and most current measurements. Manual: Front panel switch. Remote: Progrsnmsble with the Model 6162 Output/Control (optional). ISOLATION: Circuit Lo to chassis ground; greater than LO9 ohms shunted by 500 picofarads (decreas- ing to lOa ohms at 3OC and 70% relative humidity). Circuit Lo ma be
6、floated UD to tlOO0 voles with respect eo chassis ground. ANALOG OUTPUTS: Unity Gain: For dc inputs, oueput is equal to input within 20 ppm far oueput cur;ers Of 1mA or less. In Jhe fasf mode output polarity is opposite input polarity. 1 vo1c: ?l volt at up fo 1mA with respect to circuit Lo for full
7、 range inwt: 100% oelxs!Le caoaLli1iev. I tile normal mode rhe outpue pol binding poses. BCD Output: 1neerna1 coeceors for interfacing ?he Node1 6162 Isolated OutpuflConCrol. DIMENSIONS; WEIGHT: Style M 3-l/2 in. half-rack, OVer811 bench size 4 in. high x a-314 in. wide x 15-314 in. deep (100 x 220
8、x 400 mm); et weighC, 11 pounds (4,a kg). POWER: Line Operario: go-125 0r 180-250 volts (switch selected), 50-60 Hz, 9 watts. ACCESSORIES SUPPLIED: Model 6011 Input Cable: 3 ft. (lm) rriaxial cable with triaxial coector and 3 auigaeor clips. iv 0374 SECTION 1. GENERAL INFORMATION l-l. INTRODUCTION.
9、The Model 616 Digital Electro- meter is an automatic ranging, multipurpose electro- meter featuring sensitivity to 10 microvolts per digit. Its 3-l/2 digit LED display provides 0.2% voltage accuracy for a wide range of measuremente. The Model 616 is essentially a digital multimeter optimized for mea
10、surements from high source impe- dance. The 616 provides wide range capability when measuring current, resistance, and charge in addition to voltage. 1-2. WARRANTY INFORMATION. The warranty is stated an the inside front cover of the manual. l-3. CHANGE NOTICE. Improvements or changes to the instrume
11、nt not incoqmrated into the manual will be explained on a Change Notice Sheet attached to the inside back cover. 0773 1 GENERAL INFORMATION MODEL 616 TABLE 1-l. Front Panel Controls Control Power ON SENSITIITY ZERO RANGE FAST/NOW ZERO CHECK INPUT Functional Description Controls line power. Sets volt
12、age sensitivity and decimal paint. Adjusts zero affset. Sem range on a chosen function. Sets instrument for either Feedback or Shunt Mode. Places instrument in ZERO CHECK mode. Triaxial input receptacle. Paragraph - 3-4a 3-4a 3-3 3-7b 3-6 3-2a FAST/NORMAL s103 ZERO CHECK I POWEk ON SENSIiIVITY RANGE
13、 n rhe inner shield is the law inout: and the outer shield ie case ground. The m connector is a Keirhley part 0. CS-141 triaxia1 plug. b. Model 6011 Input Cable. This cable is a 30 inch long triaxial cable terminated with 3 color- coded alligator clips. The input high is identified by the heavy wire
14、 with red insulator. The input low is identified by the thin wire with black in- sulator. The case ground is identified by the thin wire with green insulator. C. Rear Panel Terminals. The rear panel has six binding posts which are used for making special connections to the Model 616. 1. Xl Terminal
15、(White). This terminal provides an analo,q signal at unity gain. CAUTION Up to 200 volts my be present at this terminal. 2. 1 Terminal (Red). This terminal provides an analog signal wivh a scale factor of 1 volt far full range input. 3. Lo Terminals (Black). These terminals provide a connection to i
16、nput low. Either terminal may be used for system connections. 4. GUARD Terminal (Blue). This terminal pro- vides a connection to the amplifier feedback when in the FAST made. 5. GROUND Terminal (Green). This terminal pro- vides a connection to chassis ground. A shorting link is provided for easy con
17、nections between lo and chassis. For floating applications, the link must be removed. GROUND 3-3. HOW TO SELECT FUNCTION. The Model 616 provides a sinele front-anel rotarv switch for selection of function and range. The RANGE Switch (5101) permits manual selection of any of four functions, namely, V
18、OLT, OHMS, COULOMB, and AMPERE. 3-4. HOW TO SE THE, VOLT FUNCTION. The Model 616 provides five decades of voltage sensitivity from .OlOOO volts to 100 volts full range. The VOLT func- tion is selected by setting the RANGE switch to VOLT. a. Manual Sensifivity Setfins. The front panel SENSITIVITY swi
19、tch has six positions. ks the switch is rotated counter clockwise, the sensitivity is increased. These positions correspond to full range sensitivities of lOO.OV, lO.OOV, l.OOOV, .lOOOV, and .OlOOOV as in Table 3-1. Position six is the AUTO sensitiviry mode which enables either *to- matic sensitivit
20、v or remotely selected sensitivitv (when used with the Model 6162). See paragraph 3-4 for a complete explanation of AUTO mode. TABLE 3-1. Voltage Sensitivity Settings Senslriviey Full Range Maximum Setting Display Display I 10 nlv .01000 v f .01999 v 100 nlv .lOOO v f .1999 v I 10 1v v 1.000 10.00 v
21、 V v f i f 1.999 19.99 v v 100 100.0 199.9 v* *The display indicates OOO.OV at 200.0 volra input. The three least significant digits will flash on and off (blinking action) to indicate an over- voltage condition. The display will continue to read up to f201.7 volts with blinking action. Be- yond f20
22、1.7 olts the display will indicate 001.7 volts with blinking action. Valtaae inputs ,q.reater than f200 volts are not r;comm 8 ranges on OHMS, 4 ranges n COULOMB, and 11 ranges on AMPERE. Since the SENSITIVITY switch is used in conjunction with the RANGE Switch, the actual number of usesble spans is
23、 12 decades on OHMS, 8 decades an COULOMB, and 11 on AMPERE. NOTE (ON AMPERE FUNCTIONl On the 10qlA t 104A ranges, the voltage be- veloped must not exceed 2 volts, otherwise, overheating of s range resistor could result. As s result, the 10 Volt and 100 volt sensi- tivity settings ate not recommende
24、d for lo-l1 to 1O-4A ranges. TO interpret a reading an OHMS, COULOMB, or AMPERE ranges both the digital display (with decimal location) snd the RANGE settig(powers of ten)shauld be cansi- dered. For example, given a digital reading of 17.32 and a RANGE setting of 1O-7 AMPERE, the actual meas- ured v