KEI 247 INST 电路图.pdf
《KEI 247 INST 电路图.pdf》由会员分享,可在线阅读,更多相关《KEI 247 INST 电路图.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、Model 247 High Voltage Supply Instruction Manual Contains Operating and Servicing Information RadioFans.CN 收音机爱 好者资料库 WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 1 year from date of shipment. Keithley Instruments, Inc.
2、 warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries, diskettes, and documentation. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. To exercise this warranty, write or call yo
3、ur local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service facility. Repairs will be made and the product returned, transportation prepaid. Repa
4、ired or replaced products are warranted for the balance of the origi- nal warranty period, or at least 90 days. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from product modification without Keithleys express written consent, or misuse of any product or part. This warrant
5、y also does not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRAN TIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FIT
6、NESS FOR A PARTICULAR USE. THE REMEDIES PROVIDED HEREIN ARE BUYERS SOLE AND EXCLUSIVE REMEDIES. NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDI- RECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS INSTRUMENTS AND SOFTWARE
7、EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIMITED TO: COSTS OF REMOVAL AND INSTALLATION, LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY PERSON, OR DAMAGE TO PROPERTY. Test Instrumentation Grou
8、p, Keithley Instruments, Inc. ? 28775 Aurora Road ? Cleveland, Ohio 44139 ? (216) 248-0400 * Fax: (216) 248-6168 CHINA: Keithley Instruments, Inc. * Holiday Inn Lido ? Office Building 4 fo.OZ% of setting/b hrs., at constant temperature after r+hour warm-up. TEMPEIUTURE COEFFICIENT (W-18C lmV,3mVp-pl
9、kV,lmA, lOHz-1OOkHz SEITLING TIME: 4 seconds to within 1V with full resistive load. OVERLOAD PROTECTIONr Short circuit proof, arc protected, self restoring. METER Monitors voltage output. ENVIRONMENT: Operating: 0 to 50C, 0 to 80% relative humidity up to 35C Storage: -40 to 75C CONNECTORz Rear panel
10、, MI-IV Type LJG931/U. POWER: 90-125V/180-25OV, 50-6OHz,13OVA. DIMENSIONS,WEIG:483mmwidex89mmhighx273deep(l9inx3/in.x103/4 in.), excluding handles. Four holes spaced for rack mounting. Net weight 5.9kg (13 Ibs.). ACCESSORIES SUPPLIEIX Instruction manual, UG932/U mating connector, mounting feet for b
11、ench operation. Specifications subject to change without notice. Table of Contents SECTION 1 - General Information 1.1 PURPOSEOFEQUIPMENT . .I- 1 1.2 DESCRIPTION . l-l 1.3 SPECIFICATIONS . l-l 1.4 sAFETYsYMEioLsANDTERMs. . l- 1 1.5 WINFoRMATION.l- 2 SECTION 2 - Operation 2.1 INSTALLATION . 2-l 2.2 F
12、RONTl?ANELCONTROLSANDTERMlNALS . .2- 1 2.3 REAR PANEL CONNECTORS AND TERMINALS . 2-2 2.4 l?REPAlK!JONFORUSE . .2- 3 2.5 INPUTPOWER . 2-3 2.6 CURRENTLIMITING . .2- 3 27 HIGH VOLTAGE OUTPUT . 2-3 2.8 APPLICATIONS . 2-4 2.8.1 Application of 247 wit therefore, it reads the output at all times. NOTE The
13、output voltage is the sum of the Voltage dial and the Voltage switch. 2-l SECTION 2 Operation 2.3 REAR PANEL CONNECTORS AND Fuse -The line power fuse (Slo-Blo) is rated 1.6A, 250V TERMINALS for 90-127V AC operation and 0.8A, 250V for 180254V AC operation. GND -The case ground screw (GND) is to be co
14、nnected to the measurement system common. Line Voltage Selector - The line voltage selector selects the appropriate line voltage 90-127VAC or MO-254V AC. Output Connector - The output connector is a h4lW type UG931/U connector. It mates with a h4HY type UG932/U connector. Line Plug - The recessed li
15、ne plug accepts a three-wire female line plug for line power. j Figure 2-l. Model 247 Front Panel Figure 2-2. Model 247 Rear Panel 2-2 SECTTON=! Opera f ion 2.4 PREPARATION FOR USE Perform the following procedure to prepare the Model 247 .- tor use: 1. 2. 3. 4. 5. 6. 7. 8. Set the Model 247 for prop
16、er line voltage operation as specified in paragraph 2.5. Connect a ground wire from case ground (on rear panel) to the measuring system common. Set the front panel controls to: A. Power switch - OFF B. Polarity switch - OFF C. Output voltage switch - 0 D. lOtumdigitaldial- 000 (full counterclockwise
17、) Plug the line cord into the power line with a three- wire receptacle to maintain proper case ground. The line fuse ratings are as follows: Line Voltage Fuse Rating 90-127VAC 1.6A, 25OV, slow blow FU-96-7 5x2On-m 180-254VAC O.SA, 25OV, slow blow, Fu-96-6 5x2Omm WARNING 2.6 CURRENT LIMITING This uni
18、t is equipped with a three-wire grounded line cord. This must be used with a three-wire receptacle where the “third wire” is connected to earth ground, otherwise per- sonal injury or death may occur. Connect the output of the Model 247 to the circuit. Use a properly rated coaxial cable with the supp
19、lied MHV type UG932/U mating connector to insure good circuit connections and safe operation. Refer to paragraph 2.6. Set the Polarity switch to the desired polarity. Turn on the power to the instrument. With actual load and output voltage, allow one hour for warm UP- Increase the Voltage switch slo
20、wly to reach the ap- proximate desired voltage. Then trim the voltage with the Voltage dial until the desired voltage level is obtained. The Model 247 includes a current limiting circuit that automatically drops the output voltage to a safe level when the rated output current is exceeded by 20%. Ref
21、er to the Maximum Current specification when operating the unit at reduced output voltages or when operating in a current limit mode for capacitor charging. 2.7 HIGH VOLTAGE OUTPUT The high voltage output connector is located on the rear panel (output LO is connected to chassis). A MHV type UG932/U
22、shielded mating connector is supplied with each unit. Assembly insinrctions for the connector are listed below. WARNING Always turn power OFF and verify that the Model 247s output meter reads OV DC, be- fore connecting or removing any equipment. External circuits may retain High Voltage af- ter the
23、Model 247 has been turned off. Dis- charge any residual voltage before connect- ing or removing any equipment. 1. 2. 3. 4. 5. 6. Gently cut through the outer insulation without cut- ting the shield. Using a sharp point, unravel the shield braid. Clean off all traces of graphite. Cut the center insul