lecroy 19_LTXXX-OM-E_Ch15 电路图.pdf
《lecroy 19_LTXXX-OM-E_Ch15 电路图.pdf》由会员分享,可在线阅读,更多相关《lecroy 19_LTXXX-OM-E_Ch15 电路图.pdf(6页珍藏版)》请在收音机爱好者资料库上搜索。
1、LTXXX-OM-E Rev BISSUED: January2002205 CH A P T E RFI F T E E NHowHistogramsWork Theoryof Operation Anunderstandingof statistical variations inparameter values is neededfor manywaveform parameter measurements. Knowledgeof theaverage, minimum, maximum, andstandarddeviationof theparameter may oftenbee
2、nough, but in manycases youmayneedamoredetailedunderstandingof thedistributionof a parameters values. Histograms allowyoutoseehowaparameters values aredistributedover manymeasurements. Theydothis by dividingarangeof parameter values intosub-ranges calledbins. Maintainedfor eachbinis acount of the nu
3、mber of parameter values events that fall withinranges of thebinitself. Whilesuchavaluerangecanbeinfinite, for practical purposes it needonlybedefinedas largeenoughto includeanyrealisticallypossibleparameter value. For example, inmeasuringTTL high-voltagevalues arangeof 50 V is unnecessarilylarge, w
4、hereas oneof 4 V 2.5 V is morereasonable. It is the5 V rangethat is then subdividedintobins. Andif thenumber of bins usedwere50, eachwouldhavearangeof 5 V/50 bins or 0.1 V/bin. Events fallingintothefirst bin wouldthenbebetween1.5 V and1.6 V. Whilethenext binwould captureall events between1.6 V and1.
5、7 V, andso on. After aprocess of several thousandevents, thebar graphof thecount for eachbin its histogram provides agoodunderstandingof thedistributionof values. Histograms generallyusethex axis toshowa bins sub-rangevalue, andthey axis for thecount of parameter values withineachbin. Theleftmost bi
6、n with anon-zerocount shows thelowest parameter valuemeasurement(s). Theverticallyhighest binshows the greatest number of events fallingwithinits sub-range. Thenumber of events inabin, peakor ahistogram is referredtoas its population. Figure 4.1 on thenext pageshows ahistograms highest populationbin
7、as theonewithasub-rangeof 4.3 to4.4 V (whichis tobe expectedof aTTL signal). 1.5 Volts 3.15 4.35 Range 10 20 30 40 Count 2 34 56 Figure 4.1 RadioFans.CN 收音机爱 好者资料库 H I S T O G R A M S 206ISSUED: January2002LTXXX-OM-E Rev B Thelowest-valuebinwithevents is that withasub-rangeof 3.0 to3.1 V. As TTL hig
8、hvoltages needtobe greater than2.5 V, thelowest binis withintheallowabletolerance. However, becauseof its proximitytothis toleranceandthedegreeof thebins separationfrom all other values, additional investigationmayberequired. DSO PROCESS TheWaverunner digital storageoscilloscope(DSO)with WAVA genera
9、tes histograms of theparameter values of input waveforms. But first, youmust definethefollowing: 1.Theparameter tobehistogrammed 2.Thetraceonwhichthehistogram is to bedisplayed 3.Themaximum number of parameter measurement values to beusedincreatingthehistogram 4.Themeasurement rangeof thehistogram 5
10、.Thenumber of bins to beused Oncethesearedefined, theoscilloscopeis readytomakethehistogram. Thesequencefor acquiringhistogram datais as follows: 1.Trigger 2.Waveform acquisition 3.Parameter calculation(s) 4.Histogram update 5.Trigger re-arm. If youset thetimebasefor non-segmentedmode, asingleacquis
11、ition occurs prior to parameter calculations. However, inSequencemodeanacquisitionfor eachsegment occurs prior to parameter calculations. If the sourceof histogram datais amemory, savingnewdatatomemoryeffectivelyacts as atrigger andacquisition. Becauseupdatingthescreencantakemuchprocessingtime, it o
12、ccurs onlyonceasecond, minimizingtrigger deadtime. Under remotecontrol thedisplaycanbeturnedoff tomaximizemeasurement speed. PARAMETER BUFFER Theoscilloscopemaintains acircular parameter buffer of thelast 20 000 measurements made, includingvalues that fall outsidetheset histogram range. If themaximu
13、m number of events tobeusedfor thehistogram is a number N less than20 000, thehistogram will becontinuouslyupdatedwith thelast N events as new acquisitions occur. If themaximum number is greater than20 000, thehistogram will beupdateduntil the number of events is equal toN. Then, if thenumber of bin
14、s or thehistogram rangeis modified, thescope will usetheparameter buffer values toredrawthehistogram witheither thelast N or 20 000 values acquired whichever is thelesser. Theparameter buffer therebyallows histograms toberedisplayed, usinganacquired set of values andsettings that produceadistributio
15、n shapewith themost useful information. RadioFans.CN 收音机爱 好者资料库 CH A P T E RFI F T E E N:How Histograms Work LTXXX-OM-E Rev BISSUED: January2002207 Inmanycases theoptimal rangeis not readilyapparent. Sothescopehas apowerful rangefindingfunction. If requiredit will examinethevalues in theparameter bu
16、ffer tocalculateanoptimal rangeandredisplaythe histogram usingit. Waverunner will alsogivearunningcount of thenumber of parameter values that fall within, below , or abovetherange. If anyvalues fall belowor abovetherange, therangefinder canthen recalculatetoincludetheseparameter values, as longas th
17、eyarestill withinthebuffer. CAPTURE OF PARAMETER EVENTS Thenumber of events capturedper waveform acquisitionor displaysweepdepends ontheparameter type. Acquisitions areinitiatedbytheoccurrenceof atrigger event. Sweeps areequivalent tothewaveform captured anddisplayedonaninput channel (1, 2, or 3 or
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- lecroy 19_LTXXX-OM-E_Ch15 电路图 19 _LTXXX OM E_Ch15
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


