1、Model 706 Scanner Instruction Manual Contains Operating and Servicing Information Publication Date: April 1991 Document Number: 706-901-01 Rev. E RadioFans.CN 收音机爱 好者资料库 WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 1 ye
2、ar from date of shipment. Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries, diskettes, and documentation. During the warranty period, we will, at our option, either repair or replace any product that proves to be de
3、fective. To exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service facility. Repairs will be made an
4、d the product returned, transportation prepaid. Repaired or replaced products are warranted for the balance of the origi- nal warranty period, or at least 90 (lays. LIMITATION OF WARRANTY This warranty does not apply to defects resulting from product modification without Keithleys express written co
5、nsent, or misuse of any product or part. This warranty also does not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or problems arising from normal wear or failure to follow instructions. ITHIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTlE S, EXPRESSED OR IMPLIED, IN
6、CLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THE REMEDIES PROVIDED HEREIN ARE BUYERS SOLE AND EXCLUSIVE REMEDIES. NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDI- RECT, SPECIAL, INCIDENTAL QR CONSEQUENTIAL DAMAGES A
7、RISING OUT OF THE USE OF ITS INSTRUMENTS AND SOFTWARE EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIMITED TO: COSTS OF REMOVAL AND INSTALLATION, LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY PE
8、RSON, OR DAMAGE TO PROPERTY. Keithley Instruments, Inc. l 28775 Aurora Road l Cleveland, OH 44139 l 216-248-0400 l Fax: 216-248-6168 l CHINA: Keitbley Instruments Cl less than 1 minute/month error (typical). BATTERY BACKUP: Rechargeable 3.6V nickel-cadmium. I month retention of data with unit turned
9、 off. OPERATING ENVIRONMENT: O” to 50C, 0% to 80% relative humidity up to 35OC. STORAGE ENVIRONMENT: -25OC to 65OC. CONNECTORS; Four BNC (lTL compatible): External Trigger, Alarm Out/Serial-In, Channel Ready, Serial Out. CAPACITY: Ten plug-in cards per mainframe. EXPANSION CAPACITY: Daisy chain allo
10、ws up to 4 SLAVE units with I MASTER unit. SWITCHING RATE: 100 channels/second (IOmsl, programmable to 1 channel/l6 minutes (999.999s). RELAY DRIVE: 4A minimum. POWER: 90-125V or 195250V (internally selected), 50Hz to 400H2, 75V.A maximum. DIMENSIONS, WEIGHT: 178mm high x 438mm wide x 448mm deep (7”
11、 x 17 l/4” x 17 3/8”). Net weight 8.6kg (19 Ibs). ACCESSORIES AVAILABLE: Model 7008-3: IEEE-488 Cable, 0.9m (3 ft.) Model 70086: IEEE-488 Cable, 1.8m (6 ft.) Model 7010: IEEE-488 Adapter for Model 85 Computer. Model 7024-I: Triaxial Cable, 0.3m (I ft.) Model 7024-3: Triaxial Cable, 0.9m (3 ft.) Mode
12、l 7024IO:Triaxial Cable, 3.0m (IO ft.1 Model 7051-2: BNC to BNC Cable, 0.6m (2 ft.) Model 7051-5: BNC to BNC Cable, 1.5m (5 ft.) Model 7052: 4 x 5 Matrix Card Model 7053: High Current Scanner Card Model 7054: High Voltage Scanner Card Model 7056: General Purpose Scanner Card Model 7057A: Thermocoupl
13、e Scanner Card Model 7058: Low Current Scanner Card Model 7059: Low Voltage Scanner Card Model 7061: Universal Interface Card Model 7068: Fixed Rack Mounting Kit for 706 Model 7069: Slide Rack Mounting Kit for 706 IEEE-488 BUS IMPLEMENTATION: Multiline Commands: DCL, LLO, SDC, GET, GTL, UNT, UNL, SP
14、E, SPD. Uniline Commands: IFC, REN, EOI, SRQ, ATN. Interface Functions: SHI, AHI, T6, TM, L4, LEO, SRI, RLI, PPO, DCI, DTI, CO, El. Programmable Parameters: Display Mode, Output Format, EOI, SRQ, Fir not programmable from bus. Stores present relay setup in buffers l-75. Recalls relay setup in buffer
15、s l-75. 1, 2, or Qpole configuration for scanning (I-pole requires 7056). O-pole for matrix card. Set time for Alarm output pulse; repeats daily. Check RAM, ROM, LEDs. Single 706 configuration. Daisy Chain configuration. Daisy Chain configuration. Display closed relays only. Clear buffer location. R
16、eset battery backup parameters to fac- tory values. Speclfi+lons subject to change without notice. Safety Precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some in- struments and accessories would normally be used w
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- KEI 706 Instruction 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf