lecroy 14_LTXXX-OM-E_Ch10 电路图.pdf
《lecroy 14_LTXXX-OM-E_Ch10 电路图.pdf》由会员分享,可在线阅读,更多相关《lecroy 14_LTXXX-OM-E_Ch10 电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、124ISSUED: January2002LTXXX-OM-E Rev B CH A P T E RTE N:UseAdvancedMathTools You have seenhowtouse Waverunnermathtools. Nowlookdeeperintowaveform processing and applythe scopes advanced mathfeatures. Inthis chapter, see how Toprocess extrema waveforms Toperformenhanced resolutionfiltering Torescale
2、yourwaveform Todomore withFFT Touse a mathfunction Toplot parametertrends RadioFans.CN 收音机爱 好者资料库 LTXXX-OM-E Rev BISSUED: January2002125 CH A P T E RTE NUseAdvancedMathTools ComputeExtremaWaveforms Useextrematoviewatraceenvelopeof numerous sweeps. Your Waverunner scoperepeatedlycompares the maxima(r
3、oof)andminima(floor)values of newwaveforms withthoseof alreadyaccumulatedextrema records. Whenever theoscilloscopefinds that agivendatapoint of anewwaveform is greater thanthe correspondingroof recordvalue, or less thanthefloor recordvalue, it replaces that recordvaluewiththenew one. TheWaverunner t
4、hus accumulates themaximum andtheminimum envelopeof all waveform records. 1.Press 1 toselect CHANNEL 1 anddisplaytheWaverunner basic menus. 2.Press thebuttonto 3.Press A toselect andset upTraceA. 3.Press thebuttonfor 5.Press thebuttontoselectanddisplaytheSETUP OF A menus. 6.Thenpressthebuttontoselec
5、t “Extrema” fromtheMathTypemenu. T TI IP P: : You canchange the viewof the envelope at anytime without affecting the accumulated data. 7.Press thebuttontoselect Envelope shows theentireenvelope, whileFloorandRoofshowonlythelower andupper parts of the envelope. Changingtheselimits will not restart th
6、eanalysis. 8.Turntheupper knob toset thenumber of sweeps: RadioFans.CN 收音机爱 好者资料库 PA R TTW O:L O O K I N GD E E P E R 126ISSUED: January2002LTXXX-OM-E Rev B 9.Press thebuttontoselect thesourcetrace: TO DOEXT RE MA Your Waverunner scope will stop accumulating whenever the selected maximum number of s
7、weeps is reached. You can interrupt this process by changing the trigger mode from N ORMA L to STOP (by pressing the STOP button), or by turning off the function trace. A ccumulation will continue when you perform the reverse action. Reset the currently accumulated extrema waveform by either pressin
8、g CL E A R SWE E PS, or changing a parameter such as gain, offset, coupling, trigger condition, or your timebase or bandwidth limit. Waverunner displays the number of currently accumulated waveforms in the displayed trace label of the zoom trace on which the extrema function is performed. You can di
9、splay roof and floor records either individually or together. Whenever the maximum number of sweeps is reached, you can accumulate an even larger number simply by changing the value in the SE TUP for menu. However, leave the other parameters unchanged, or the calculation will be restarted. T TI IP P
10、: : Waverunneravoids being slowed downbycomputing a particularmath functiononlywhenthat functions trace is turned on. Despite this, waveform processing cantake some time whenthere are manydata points. Cut this delayby limiting the numberof data points used inthe computation. Waverunnerwill process t
11、he entire waveformbytaking everynthpoint where ndepends onthe timebase and the desired maximumnumberof points. The first point takenis always the data value at the left-hand edge of the display. RadioFans.CN 收音机爱 好者资料库 CH A P T E RTE N:UseAdvancedMathTools LTXXX-OM-E Rev BISSUED: January2002127 Resc
12、aleandAssignUnits This advancedmathtool allows youtoapplyamultiplicationfactor (a), andadditiveconstant (b), toyour waveform. Youcandoit intheunit of your choice, dependingonthetypeof application. 1.Followthesteps for settinguptodomathonTraceA, B, C or D. 2.Pressthebuttontoselect RescalefromtheMathT
13、ypemenu. 3.Select a or b from thenext menu, belowMathType. 4.Press thebuttontoselect themantissa, exponent, or number of digits; turntheknobtoset its value. 5.If youwish, go backandselect units. A newmenu, called“units =” will thenappear andallowyouto defineoneof awiderangeof units for your chosenva
14、lue, includingAmps, Celsius, Hertz, decibels, Kelvin, Ohms, Volts, andWatts. 6.Press thebuttontoselect thesourcetracefor filtering: TO DOAVE RAGIN G: SUMME D VSCON T IN UOUS(OPT ION) Summed A veraging is the repeated addition, with equal weight, of successive source waveform records. If a stable tri
15、gger is available, the resulting average has a random noise component lower than that of a single-shot record. Whenever the maximum number of sweeps is reached, the averaging process stops. A n even larger number can be accumulated simply by changing the number in the menu. However, the other parame
16、ters must be left unchanged or a new averaging calculation will be started. You can interrupt the averaging by changing the trigger mode from N ORM to STOP, or by turning off the active trace. Waverunner resumes averaging when you perform the opposite action to these. Reset the accumulated average b
17、y pushing the CL E A R SWE E PS button or changing an acquisition parameter such as input gain, offset, coupling, trigger condition, timebase, or bandwidth limit. The number of current averaged waveforms of the function, or its zoom, is shown in the displayed trace label. When summed averaging is pe
18、rformed, the display is updated at a reduced rate about once every 1.5 s in order to increase the averaging speed (points and events per second). Continuous Averagingis the repeated addition, with unequal weight, of successive source waveforms. It is particularly useful for reducing noise on signals
19、 that drift very slowly in time or amplitude. The most recently acquired waveform has more weight than all the previously acquired ones: the continuous average is dominated by the statistical fluctuations of the most recently acquired waveform. The weight of old waveforms in the continuous average g
20、radually tends to zero (following an exponential rule) at a rate that decreases as the weight increases. PA R TTW O:L O O K I N GD E E P E R 128ISSUED: January2002LTXXX-OM-E Rev B EnhanceResolution ERES (EnhancedResolution)filteringincreases vertical resolution, allowingyoutodistinguishcloselyspaced
21、 voltagelevels. Waverunner ERES is similar tosmoothingthesignal withasimple, moving-averagefilter. However, it is moreefficient, bothinterms of bandwidthandpass-band. UseERES onsingle-shot waveforms, or wherethedatarecordis slowlyrepetitive whenyoucant useaveraging. Useit toreducenoisewhenyour signa
22、l is noticeablynoisy, but youdont needto perform noisemeasurements. Useit, too, whenyouperform high-precisionvoltagemeasurements: zoomingwithhighvertical gain, for example. 1.Followthesteps for settinguptodomathonTraceA, B, C, or D. 2.Then press thebuttontoselect Enh. Res from theMathTypemenu: 3.Pre
23、ss thebuttontoselect 1.5 bits, for example, from This menuallows youtochooseafilter that will enhancetheresolutionof thedisplayedsignal byfrom oneto threebits, in steps of 0.5 bits. 4.Press thebuttontoselect thesourcetracefor filtering: Result: Seeillustrationnext page. T TI IP P: : Depending onyour
24、sampling speed, Waverunnerdigital filters canaffect bandwidth. If you need bandwidthat slow timebases, use Averaging withrepetitive sampling. CH A P T E RTE N:UseAdvancedMathTools LTXXX-OM-E Rev BISSUED: January2002129 The glitch in the waveform displayed on the top grid has been clearly eliminated
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- lecroy 14_LTXXX-OM-E_Ch10 电路图 14 _LTXXX OM E_Ch10
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


