1、LeCroy 1996 Test 100 MHz on EXT input with ECl, TIL or zero crOSSing levels. TRIGGERING SYSTEM Trigger Modes: Normal, Auto, Single, Stop. Trigger Sources: CH1, CH2, CH3, CH4, Line, Ext, Ext/l0. Slope, level and Coupling for each can be set indepen- dently. Slope: Positive, Negative, Window (BiSlope)
2、. Coupling: AC, DC, HF (up to 500 MHz), lFREJ, HFREJ. Pre-trigger recording: 0 to 100% of full scale (adjustable in 1% div increments). Post-trigger delay: 0 to 10,000 divisions (adjustable in 0.1 div incre- ments). Holdoff by time: 10 ns to 20 s. Holdoff by events: 0 to 99,999,999 events. Internal
3、Trigger Sensitivity Range: 5 div. EXT Trigger Max. Input: 1 MQ/ /15 pF: 250 V (DC+peak AC:; 10 kHz) 50Q 1%: 5 V DC (500 mW) or 5 V RMS EXT Trigger Range: 0.5V (5V with Extjl0). Trigger Timing: Trigger Date and Time are listed in the Memory Status Menu. SMART TRIGGER TYPES Signal Width: Trigger on wi
4、dth between two limits selectable from 2.5ns to 20s. Signal Interval: Trigger on interval be- tween two limits selectable from iOns to 20s. Dropout: Trigger if the input signal drops out for longer than a time-out from 25ns to 20s. State/Edge Qualified: Trigger on any source only if a given state (o
5、r transi- tion) has occurred on another source. The delay between these events can be defined as a number of events on the trigger channel or as a time interval. TV: Allows selection of both line (up to 1500) and field number (up to 8) for PAL, SECAM, NTSC or non-standard video. ACQUISITION MODES Ra
6、ndom Interleaved Sampling (RIS): for repetitive signals from 1 ns/div to 5 ms/div. Singte shot: for transient and repetitive signals from 50 ns/div. Sequence: Stores multiple events in segmented acquisition memories. Number of segments available: 9304A 2-200 9304AM 2-500 Dead Time between segments:
7、:;150 ms DISPLAY Waveform style: Vectors connect the individual sample points, which are highlighted as dots. Vectors may be switched off. CRT: 12.5 x 17.5 cm (9 diagonal) raster. Resolution: 810 x 696 points. Modes: Normal, X-Y, Variable or Infinite Persistence. Real-time Clock: Date, hours, minute
8、s, seconds. Graticules: Internally generated; sepa- rate intensity control for grids and wave- forms. Grids: 1, 2 or 4 grids. Formats: YT, XY, and both together. Vertical Zoom: Up to 5x Vertical ExpanSion (50 x with averaging, up to 40 mV sensitivity). Maximum Horizontal Zoom Factors: 9304A l,OOOx 9
9、304AM 5,OOOx INTERNAL MEMORY Waveform Memory: Up to four 16-bit Memories (Ml, M2, M3, M4). ProceSSing Memory: Up to four i6-bit Waveform Processing Memories (A,B,C,D). Setup Memory: Four non-volatile memo- ries. Optional Memory Cards, PCMCIA portable hard drive or Floppy Disks may also be used for h
10、igh-capacity waveform and setup storage. WAVEFORM PROCESSING Up to four processing functions may be performed simultaneously. Functions available are: Add, Subtract, Multiply, Divide, Negate, Identity, Sin(x)/x and Summation Averaging. Average: Summed averaging of up to 1,000 waveforms in the basic
11、instru- ment. Up to 106 averages are possible with Option WPOi. Envelope*: Max, Min, or Max and Min values of from 1 to 106 waveforms. ERES*: low-Pass digital filter provides up to 11 bits vertical resolution. Sampled data is always available, even when trace is turned off. Any of the above modes ca
12、n be invoked without destroying the data. FFT*: Spectral Analysis with four win- dowing functions and FFT averaging. * Envelope and ERES modes are provid- ed in Math Package WP01, FFT is in WP02. AUTOMATIC MEASUREMENTS The following Parametric measurements are available, together with statistics of
13、their Average, Highest, lowest values and Standard Deviation: amplitude il.t at level (t=O,abs) overshoot + area il.t at level (t.()%) overshoot base duty cycle peak to peak cmean falltime period cmedian f8020% risetime crms flevel (abs) r2()80% csdev flevel (%) rlevel (abs) cycles frequency rlevel
14、(%) delay maximum RMS Melay mean std dev il.t at level (abs) median top il.t at level (%) minimum width Parameters are calculated as defined by ANSI/IEEE Std 181-1977 Standard on Pulse Measurement and Analysis by Objective Techniques. In addition, Rise and Fall times may be measured at 10 % and 90%
15、levels, or 20% and 80% levels, or any other user-specified levels. 6delay provides time between mid- point transition of two sources, for making propagation delay measure- ments. 6t at level allows the same measure- ment to be made at any specified level. Two cursors are used to define the region ov
16、er which these parameters are calculated. Relative Time: Two cursors provide time measurements with resolution of 0.05% full scale for unexpanded traces; up to 10 % of the sampling interval for expanded traces. The cor- responding frequency value is also dis- played. Relative Voltage: Two horizontal
17、 bars measure voltage differences up to 0.2% of fullscale in single-grid mode. Absolute Time: A cross hair marker measures time relative to the trigger, and voltage with respect to ground. Pass/Fail testing allow up to five of the listed parameters to be tested against selectable thresholds. Wavefor
18、m Limit Testing is performed using templates which may be defined inside the instrument. AUTOSETUP Pressing Autosetup sets timebase, trigger and sensitivity to display a wide range of repetitive signals. (Amplitude 2mV to 40V; frequency above 50Hz; Duty cycle greater than 0.1%). Autosetup Time: Appr
19、oximately 2 sec- onds. Vertical Find: Automatically sets sensi- tivity and offset. PROBES Model: One PP002 (10:1, 10 MQ / / 15 pF) probe supplied per channel. The 9304A and 9304AM are fully com- patible with LeCroys range of FET Probes, which may be purchased sep- arately. Probe calibration: Max 1 V
20、 into 1 MQ, 500 mV into 50Q , frequency and amplitude programmable, pulse or square wave selectable, rise and fail time 1 ns typical. Alternatively, the Calibrator output can provide a trigger output or a PASS/FAIL test output. INTERFACING Remote Control: Of all front-panel con- trols, as well as al
21、l internal functions is possible by GPIB and RS-232-C. RS-232-C Port: Asynchronous up to 19,200 baud for computer/terminal control or printer/plotter connection. GPIB Port: (IEEE-488.1) Configurable as talker/listener for computer control and fast data transfer. Command Language complies with requir
22、ements of IEEE-488.2. Centronics Port: Optional hardcopy parallel interface included with floppy disk and graphics printer options. Hardcopy: Screen dumps are activated by a front-panel button or via remote control. TIFF and BMP formats are available for importing to Desktop Publishing programs. The
23、 following printers and plotters can be used to make hardcopies: HP DeskJet (color or B sepa- rate intensity control for grids and wave- forms. Grids: 1, 2 or 4 grids. Formats: YT, XY, and both together. Vertical Zoom: Up to 5x Vertical Expansion (50 x with averaging, up to 40 mV sensitivity). Maxim
24、um Horizontal Zoom Factors: 9310A, 9314A l ,OOOx 9310AM, 9314AM 5,000 x 9310AL, 9314AL 20,000 x INTERNAL MEMORY Waveform Memory: Up to four 16-bit Memories (Ml, M2, M3, M4). Processing Memory: Up to four 16-bit Waveform Processing Memories (A, B, C, D). Setup Memory: Four non-voiatile memo- ries. Op