1、Table of Contents General Information Table of Contents Manuals .i Using This Manual .i Warranty .iii Product Assistance .iv Maintenance Agreements .iv Service Procedure .iv Safety Precautions .vii ESD Precaution . .viii Plug-in Module Installation and Removal .x Section 1: Product Description1-1 Bl
2、ock Diagram .I-4 Section 2: Installation2-1 Attach Line Cord .2-1 Operate in Proper Environment .2-1 Apply Power .2-2 Selecting the Computer Port .2-2 Setting the GPIB Address .2-2 GPIB Host and Hardcopy Operation .2-3 RS-232-C Configuration .2-7 Install the Plug-in(s) .2-12 Section 3: Operation3-1
3、Overview .3-1 7200A Mainframe Front Panel .3-10 Acquisition Keys .3-11 TOC-1 RadioFans.CN 收音机爱 好者资料库 Table of Contents Waveform Display and Measurement .3-15 Panel Settings Storage .3-51 Hardcopy .3-51 Programming .3-51 Using Setup Screens .3-53 Configure System .3-54 Setting Up Traces and Processin
4、g Functions .3-56 Extended Parameter Setup .3-89 Persistence Setup Screen .3-99 Multi Zoom Setup Screen .3-101 Hardcopy Setup .3-103 Waveform Storage Setup .3-112 Waveform Recall Setup .3-115 Disk Utilities .3-118 Configure System .3-127 Program Setup .3-139 7242 Series Operators Manual4-1 The 7242
5、Series .4-1 Accessories and Options .4-1 Specifications .4-1 Installation .4-3 Install the Plug-in(s) .4-3 Operation .4-4 Probes .4-4 Control Layout .4-5 Display of Acquisition Settings .4-6 7242 Series Plug-in Front Panel Controls .4-8 TOC RadioFans.CN 收音机爱 好者资料库 Table of Contents Index to Controls
6、 .4-9 Vertical Controls .4-10 Timebase Controls .4-12 Trigger Controls .4-14 VERTICAL Status .4-17 TIMEBASE Status .4-20 TRIGGER Status .4-25 Standard Trigger .4-27 Smart Trigger .4-27 Single Source .4-30 Pattern . .4-34 State Qualified .4-39 Time Qualified .4-45 TV .4-50 Plug-in Status .4-51 7234 P
7、lug-in Operators Manual4-53 Installation .4-55 Install the Plug-in(s) .4-55 Operation .4-57 Probes .4-57 Control Layout .4-58 Display of Acquisition Settings .4-59 7234 Plug-in Front Panel Controls: .4-61 Vertical Controls .4-63 Timebase Controls .4-66 Trigger Controls .4-67 VERTICAL Status .4-71 TO
8、C-3 RadioFans.CN 收音机爱 好者资料库 Table of Contents TIMEBASE Status .4-74 TRIGGER Status .4-79 Standard Trigger .4-81 Smart Trigger TM . 4-81 Single Source .4-84 Pattern .4-88 State Qualified .4-93 Time Qualified .4-99 Plug-in Status .4-104 Appendix AA-I Summary of Waveform Processing, Display, and Storag
9、e .A-I Appendix BB-I Raekmount Installation .B-1 Appendix CC-I Accessories .C-1 Appendix D - 7291 2GS/sec AdaptorD-1 Features .D-1 Calibration .D-2 Operation .D-4 Appendix E - 7200ARCLK Installation, Test and Cal Procedure E-1 How to Use This Manual .E-1 Installation .E-3 Calibration .E-5 Test .E-6
10、TOC4 Table of Contents Appendix F - 7200A-IF2 Installation . . .; . . .+ 1+ + +:+ Floppy Disk Hard Disk I IEEE-488 I Plotters, RS.232-C Printers and Centronlcs Remote Control External Reference IN/OUT Analog Inputs External Sample Clock Analog Inputs External Sample Clock Trigger IN/OUT Figure 1.1:
11、7200A Block Diagram 1-4 Section 2: Installation The 7200A runs over the full line voltage range of 90 Volt to 250 Volt AC rms and source fre- quencies of 47 to 63 Hertz. The 7200A is shipped with the fuse drawer and fuses most common to its destination al- ready installed in the line cord connector
12、(rear panel). Attach Line Cord The AC input receptacle (CEE-22 style) located in the line cord connector (rear panel) three recessed male pins which accept the detachable line cord. To obtain an AC line cord other than the one supplied, please contact the factory. Operate in Proper Environment WARNI
13、NG: To avoid explosion, do not operate the 7200A in an atmosphere of explosive gases. To ensure proper operation and long instrument life, the 7200A should be operated within the following environmental conditions: Temperature Ambient air temperatures between 0 to +40 C. Storage temperatures can ran
14、ge between -40 to +75 C. Ventilation The Model 7200A is cooled by air drawn from the bottom front and exhausted through the rear. Operate the instrument on a hard flat surface, or carpeting of very low pile. Allow at least one half inch clearance under the bottom and 2 behind the rear fans and along
15、 the side panels. Grounding Ensure a good ground. The Model 7200A is a Safety Class 1 instrument. Its exposed metal chassis is directly connected to earth via the power supply cord. 2-1 Setting the GPIB Address WARNING: To avoid possible shock hazard, ground the 7200A chassis by connecting the power
16、 supply cord to an earth grounded AC power receptacle. Do not make any connections to the instruments input or output terminals until the 7200A is properly grounded. Apply Power CAUTION: Use correct power source. The Model 7200A is designed to operate from a single-phase power source. The voltage to
17、 ground (earth) from either pole of the power source must not exceed the maximum rated operating voltage, 250 Volts AC rms. To supply power to the 7200A, set its rear panel ON/OFF switch to the ON (I) position. Selecting the Computer Port CAUTION: Before connecting external equipment to the 7200A, s