1、VT-187 only FRONT PANEL VT-185: (A63-0303-08) VT-186: (A63-0304-08) VT-187: (A63-0305-08) SIDE PANEL (A13-2254-08) PUSH KNOB (K24-3015-08) HANDLE: (K01-0564-08) HANDLE COVER : (B09-0410-08) ROTARY KNOB (K21-0960-08) RUBBER FOOT (J02-0543-08) 2CH AC VOLTMETER VT-185/VT-186/VT-187 SERVICE MANUAL KENWO
2、OD TMI CORPORATION 1998-8/B51-1134-00 (K/K) VT185(K)internet 98.7.30 15:29 y W 2 RadioFans.CN 收音机爱 好者资料库 VT-185/VT-186/VT-187 2 The following instructions are for use by qualified personnel only. To avoid electric shock, do not perform any servicing other than contained in the operating instructions
3、 unless you are qualified to do so. WARNING CONTENTS SPECIFICATIONS .3 SAFETY .4 CIRCUIT DESCRIPTION.5 BLOCK DIAGRAM .6 ADJUSTMENT.7 PARTS LIST (UNIT).10 PARTS LIST (ELECTRICAL).11 SCHEMATIC DIAGRAM .16 P.C. BOARD .26 VT185(K)internet 98.7.30 15:29 y W 3 RadioFans.CN 收音机爱 好者资料库 Gain Output voltage O
4、utput resistance Distortion Signal to noise ratio Frequency response ITEMS Meter Section VT-185 Amplifier Section VT-186VT-187 Measurable voltage dB dBm Error Frequency response Input impedance Max. input voltage Stability Residual Voltage Crosstalk Individual Crosstolk Interlock 1mV to 300mV in ran
5、ges: 1, 3, 10, 30, 100, 300mV, 1 , 3, 10, 30, 100, 300V full scal. 0.3mV to 100mV in 12 ranges : 0.3, 1, 3, 10, 30, 100, 300mV, 1, 3, 10, 30, 100V full scale. -80 to +50dB (0dB=1V)-90 to +40dB (0dB=1V) -80 to +52dBm (0dBm=1mW at 600) -90 to +42dBm (0dBm=1mW at 600) Within 3% of full scale at 1kHz 10
6、% at 5Hz to 1MHz, 5% at 10Hz to 500kHz, 3% at 20Hz to 200kHz and 2% at 30Hz to 100kHz as response to 1KHz response. 10M 5%, with less than 45pF parallel capacitance. 500V(DC +AC peak) 1V to 300V range 100V(DC +AC peak) 1mV to 300mV range 500V(DC +AC peak) 1V to 100V range 100V(DC +AC peak) 0.3mV to
7、300mV range Within 0.5% of full scale for 10% line voltage fluctuation Less than 20 V with input shorted on 1mV range Less than 30 V with input shorted on 0.3mV range Less than -50dB with other input terminated with 600 Less than -80dB with other input terminated with 600 Approx. 60dBApprox. 70dB 1V
8、rms (full scale) 20% 600 20% at 1kHz Less than 1% at full scale (Rated by signal to noise ratio in 0.3mV, 1mV and 1V range). Less than 1% at full scale (Rated by signal noise ratio in 1mV and 1V ranges) Over 40dB at full scale. (Over 30dB at 0.3mV range) Within 3dB at 5Hz to 500kHz Line voltage Powe
9、r consumption Dimensions W X H X D (mm) Environmental Power Supply Section Coefficient Temperature Relative humidity Maximum altitude Overvoltage Category Pollution Degree : 0.08%/C Within specifications :10 to 40C Full operation:0 to 50C Less than 80% 2000m 2 100/120/220/230 Vac 10% 50/60Hz Max. 11
10、W 128 (128) X 190 (210) X 239 (269) Value in ( ) include protrusions Approx. 3.2 kgApprox. 3.1 kgNet Weight 1 pc. CA-41p 2 pcs. 1 pc. 1 copy 1 pc. EN55011 (1991) CLASS B IEC801-2 (1991) 8kVAD IEC801-3 (1984) 3V/M IEC801-4 (1988) Accessories Power cable Input cable Replacement fuse Instruction manual
11、 Adjust driver Regulatory Information (VT-186 only) EMI Immunity 7 The above specifications are subject to charge without noise. VT-185/VT-186/VT-187 3 SPECIFICATIONS VT185(K)internet 98.7.30 15:31 y W 6 RadioFans.CN 收音机爱 好者资料库 VT-185/VT-186/VT-187 4 SAFETY SAFETY Before connecting the instrument to
12、 a power source, care- fully read the following information, then verify that the proper power cord is used and the proper line fuse is installed for power source. The specified voltage is shown on the rear panel. If the power cord is not applied for specified voltage, there is always a certain amou
13、nt of dan- ger of electric shock. Line voltage This instrument operates using ac-power input voltages that 100/120/220/230 V at frequencies from 50 Hz to 60Hz. Power cord The ground wire of the 3-wire AC power plug places the chassis and housing of the instrument at earth ground. Do not attempt to d
14、efeat the ground wire connection or float the instrument ; to do so may pose a great safety hazard. The appropriate power cord is supplied as an option that is specified when the instrument is ordered. The optional power cords are shown as follows in Fig.1 Line fuse The fuse holder is located on the
15、 rear panel and contains the line fuse. Verify that the proper fuse is installed by replacing the line fuse. Voltage conversion This instrument can be operated from 100 to 230V, 50/60Hz power source. Use the following procedure to change from 100 to 230V operation or vice versa. 1. Remove the fuse h
16、older. 2. Replace fuse F1 with a fuse of appropriate value. 3. Reinsert it for appropriate voltage range. 4. When performing the reinsertion of fuse holder for the voltage conversion, the appropriate power cord should be used. (See fig.1) North American 120 volt/60 Hz Rated 15 amp (12 amp max ; NEC)
17、 Universal Europe 230 volt/50 Hz Rated 16 amp U.K. 230 volt/50 Hz Rated 5 amp Australian 240 volt/50 Hz Rated 10 amp North American 240 volt/60 Hz Rated 15 amp (12 amp max ; NEC) Switzerland 230 volt/50Hz Rated 10 amp Fig.1 Power Input Voltage Configuration Plug configurationpower cord and plug type
18、 Factory installed instrument fuse 0.2A, 250V slow blow 5x20mm 0.1A, 250V slow blow 5x20 mm 0.1A, 250V slow blow 5x20 mm 0.1A, 250V slow blow 5x20 mm 0.2A, 250V slow blow 5x20mm 0.3A, 250V slow blow 5x20 mm Line cord plug fuse None None None Parts No. for power cord E30-1982-08 E30-1985-08 E30-1986-
19、08 None 5A Type C None E30-1983-08 VT185(K)internet 98.7.30 15:31 y W 7 General A Signal voltage to be measured, which is input from the INPUT connector, is passed through the First Attenuator and is converted to a low impedance by the Impedance Convertor. The impedance-converted signal is normalize
20、d, or further attenuated in proportion to 1mVrms fullscale value through the Second and Third Attenuator. The normalized signal is magnified 20-fold by the Main Amplifier and is fed to the Output Amplifier and the Absolute-Mean Value Detec- tor. The Output Amplifier magnifies the signal 50-fold and
21、feeds to the OUTPUT connector. The Absolute-Mean Value Detector converts the signal from the Main Amplifier to DC current in proportion to the absolute mean value. The con- verted signal activates the Meter. The Attenuator Control encodes the signal led from the RANGE selector to generate an Attenua
22、tor Control signal. This signal controls the First, Second and Third Attenuator to set the sensitivity corresponding to each range. The Power Supply feeds to the functional circuit 5V DC voltages stabilized by its IC regulator. Description of Functional Circuit 1) First Attenuator A potential divide
23、r acts as an attenuator. The amount of attenuation is switched in two steps by relay contacts:0dB and -60dB. 2) Impedance Converter A FET differential input Amplifier acts as an impedance con- verter with 0dB(10dB) gain, which converts the First Attenu- ator output signal to a sufficiently low imped