1、LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge NY 10977-6499 USA Phone: 1-800-5-LECROY 1-914-425-2000 FAX: 1-914-425-8967 WP03 -PARAMETER ANALYSIS PACKAGE OPERATION AND PROGRAMMING MANUAL 9300 SERIES DIGITAL STORAGE OSCILLOSCOPES RadioFans.CN 收音机爱 好者资料库 ? ?!? 700 Chestnut Ridge Road Chest
2、nut Ridge, NY 109776499 Tel: (914) 578 6020, Fax: (914) 578 5985 ?#? 2, rue du Pr-de-la-Fontaine 1217 Meyrin 1/Geneva, Switzerland Tel: (41) 22 719 21 11, Fax: (41) 22 782 39 15 $?%? Copyright July 1998, LeCroy. All rights reserved. Information in this publication supersedes all earlier versions. Sp
3、ecifications subject to change. LeCroy, ProBus and SMART Trigger are registered trademarks of LeCroy Corporation. Centronics is a registered trademark of Data Computer Corp. Epson is a registered trademark of Epson America Inc. I2C is a trademark of Philips. MathCad is a registered trademark of MATH
4、SOFT Inc. MATLAB is a registered trademark of The MathWorks, Inc. Microsoft, MS and Microsoft Access are registered trademarks, and Windows and NT trademarks, of Microsoft Corporation. PowerPC is a registered trademark of IBM Microelectronics. DeskJet, ThinkJet, QuietJet, LaserJet, PaintJet, HP 7470
5、 and HP 7550 are registered trademarks of Hewlett-Packard Company. LCXXX-WPO3-OM-ERev D0898 RadioFans.CN 收音机爱 好者资料库 ? ? ? ?.11 ? ? ?. 21 ?!? ?.210 ?#?$? ?.31 ?.32 ?.33 ? .34 ?.35 ?.36 ?.37 ? !?.38 ? .39 #?.310 ?$?.311 ?.312 $?%?%?.313 $? sigma = bin count *(bin value -mean) bin count 1ii 2 i i 1 n i
6、 1 n /() = , where n is the number of bins in the histogram, bin count is the count or height of a bin and bin value is the center value of the range of parameter values a bin can represent. ?For the histogram: Value (volts) Count# 4.14.04.24.34.4 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 mean = ( 2 * 4.1 + 3*
7、4.3 + 1 * 4.4) / 6 = 4.25 sigma = (2*(4.1 - 4.25) + 3*(4.3 - 4.25) + 1*(4.4 - 4.25) ) / (6-1) 222 = .1225 ? ? ?$?$? #?Calculates the total population of a histogram between the parameter cursors. #?$?The count for all populated bins between the parameter cursors is summed. ? Count 1 2 3 4 5 The tota
8、l population of this histogram is 9. ? ? (?$01?(2?0 #?Returns the value of the xxth peak that is the largest by area in a histogram. #?$? First the peaks in a histogram are determined and ranked in order of total area (for a discussion on how peaks are identified see the description for the pks para
9、meter). The center of the nth ranked peak (the point where the area to the left is equal to the area to the right), where n is selected by the user, is then returned as xapk. ?The rightmost peak is the largest, and thus the first-ranked, in area (1). The leftmost peak, although higher, is ranked sec
10、ond by area (2). The lowest peak is also the smallest in area (3). Largest-area peak 1 2 3 3? ? 3 ?4? The Trend waveform processing function enables the creation of graphs of successive waveform parameter measurement values. It provides useful visual information on waveform parameter variation. And,
11、 used together with other scope features, it allows the graphing of certain parameters against others. ? 1. Select and configure a custom parameter, which will be used to perform the measurement that is to be trended. This can be done by either: ?choosing “Custom” mode from the “MEASURE” “Parameters
12、” menu group as for histograms (see page 13 of the present manual and the CURSORS/MEASURE ? To set the number of points in certain math functions, using the associated menu knob. 3? ? ? ?The display of defined traces is controlled by the TRACE ON/OFF buttons. ?Expansion, or zooming, and positioning
13、of traces is controlled by the horizontal and vertical ZOOM and POSITION knobs. ?When Multi-zoom is on, the ZOOM and POSITION knobs are coupled and control all displayed traces at once. This is particularly useful when multiple trends of related parameters are displayed. ?The button resets the multi
14、plier for the trace expansion to 1 and the offset positioning to 0. The button should be pressed for each reconfigured trace in order that traces can be cleanly and correctly positioned on-screen. 3? ? *8?;?6 ?! allows the selected trace (here, Trace A) to be set up for trending. ? To define the tre
15、nd as using math necessary for the trend itself to be defined. Traces can be defined to use math or as zooms of other traces. As trending is a math function, “use Math?” should be set to “Yes”, using the corresponding menu button. ?%$? For selecting “Trend”. ?6-8?-89#?*8?;? To access more trend setu
16、p options and the final trend-dedicated menu (next page). ?9#?89?8-?!9#?8?=? For positioning the trend automatically once it has been calculated. “FIND CENTER AND HEIGHT” places the trace appropriately, centering and scaling the trend without affecting the zoom and position settings. But ensure that
17、 these settings have been reset (as described on the previous page). ? To select the parameter for trending, using the corresponding menu button or associated knob. Any of the configured parameters, displayed on the line beneath the grid, can be chosen. ;?$? For selecting using button or knob the nu
18、mber of values in the trend. A maximum of 20 000 values can be chosen for any one trend. When this maximum is exceeded, the parameter results scroll off the trend. 3? ? ? Press after having configured the parameter in “CHANGE PARAM” to return to the menus shown this page. ?-89#?!? this menu group ap
19、pears when “MORE TREND SETUP” is selected (previous page). ? To select “All” for every parameter calculation on each waveform to be placed in the trend. Or “Average” to trend only the average of all the given values calculated on a given acquisition, and to obtain one point in the trend per acquisit
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- LeCroy_WP03_Parameter_Analysis_Package_Programming_Manual_A 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-202771.html



Marshall-9100-62-02-Schematic电路原理图.pdf
德国AEG 679WK电路原理图.jpg
德国AEG AEG 67W电路原理图.gif