1、 Part No. Z1-002-532, IB002983 Aug. 2003 OPERATION MANUAL BIPOLAR POWER SUPPLY PBX Series PBX20-5 PBX20-10 PBX20-20 PBX40-2.5 PBX40-5 PBX40-10 RadioFans.CN 收音机爱 好者资料库 Use of Operation Manual Please read through and understand this Operation Manual before operating the product. After reading, always
2、keep the manual nearby so that you may refer to it as needed. When moving the product to another location, be sure to bring the manual as well. If you find any incorrectly arranged or missing pages in this manual, they will be replaced. If the manual it gets lost or soiled, a new copy can be provide
3、d for a fee. In either case, please contact Kikusui distributor/ agent, and provide the “Kikusui Part No.” given on the cover. This manual has been prepared with the utmost care; however, if you have any questions, or note any errors or omissions, please contact Kikusui distributor/agent. Reproducti
4、on and reprinting of this operation manual, whole or partially, without our permission is prohibited. Both unit specifications and manual contents are subject to change without notice. Copyright 2001-2003 Kikusui Electronics Corporation Printed in Japan. RadioFans.CN 收音机爱 好者资料库 I WARNINGSCaution ROM
5、 Version Number This manual is applicable to the power supplies which have the following version of ROM (read only mem- ory). 2.0 ( denotes 0 to 9.) When making any inquires on your power supply, please indicate the following: Model No. ROM Version No. Serial No. To find the ROM Version No., please
6、refer to Section 2.3 Power Turn-on under Chaper 2 PRECAUTIOS AND PREPARATIVE PROCEDURES. The Serial No. is indicated on the rear panel. and Before start using the power supply and during using it, be sure to read and strictly observe the instructions given in the following: WARNINGS AND CAUTIONS (ne
7、xt page) Chapter 2 PRECAUTIONS AND PREPARATIVE PROCEDURES RadioFans.CN 收音机爱 好者资料库 Chapter 3 OPERATING METHOD The former half of this chapter introduces the names and functions of keys, indicators and other panel items, and the basic operating methods of the power supply; the latter half describes pr
8、ocedures for sequence operation and other applied types of operation. Contents Page 3.1Description of Front and Rear Panels. 3-3 3.1.1 Front Panel. 3-3 3.1.2 Rear Panel. 3-3 3.1.3 Functional Block Diagram . 3-5 3.2Basic Operating Method 1 . 3-7 3.2.1 Turning ON/OFF the POWER Switch . 3-7 3.2.2 Basic
9、 Panel Operating Method. 3-7 3.2.3 Selecting the C.V or C.C Mode. 3-12 3.2.4 Voltage (or Current) Settings and Output ON/OFF. 3-13 3.2.5 Fine Setting of Output Voltage (or Current) . 3-15 3.2.6 Setting of Protective Functions . 3-17 3.2.7 To Reset from Protective Alarm Status. 3-23 3.2.8 Meter Funct
10、ion . 3-25 3.3Basic Operating Method 2 . 3-29 3.3.1 Remote Sensing Function. 3-29 3.3.2 Memory Function . 3-30 3.3.3 Setup Function. 3-32 3.3.4 Keylock Function . 3-39 3.3.5 Setting the Click Resolution. 3-40 3.3.6 Setting the Rise/Fall Time and The Frequency Response for an External Signal. 3-41 3.
11、3.7 Displaying the Interface Status. 3-42 3.4Sequence Operation . 3-43 3.4.1 Description of Sequence Operation. 3-43 3.4.2 Outline of Settings for Sequence Operation. 3-49 3.4.3 Procedures for Sequence Operation . 3-50 3.5Applied Types of Operation . 3-65 3.5.1 Configuration. 3-65 3.5.2 Analog Remot
12、e Control. 3-74 3.5.3 Amplitude Setting Function . 3-81 Chapter 3. OPERATING METHOD 3-2 MEMO Chapter 3. OPERATING METHOD 3-3 3.1 Descriptions of Front and Rear Panels 3.1.1 Front Panel Refer to chapter 5. 5.1 Front Panel. 3.1.2 Rear Panel Refer to chapter 5. 5.2 Rear Panel. Chapter 3. OPERATING METH
13、OD 3-4 MEMO Chapter 3. OPERATING METHOD 3-44 The features of the Normal speed mode and Fast speed mode of sequence operation are compared in the following table. The Fast speed sequence is available only when the power supply is in the fast C.V mode or dynamic C.C mode. (Refer to Section 2.4 Operati
14、ng Mode Selection.) The output voltage (or current) rises or falls with the Tr Tf time setting. Therefore, when the programmed execution time for one step is shorter than Tr Tf time, the output may not reach the values specified by the program. At the fast speed sequence operation mode when two prog
15、rams of one step or two steps chained each other are executed at high speed, normal processing may not be done by the occurrence of a reception error for a message through RS-232C. Change programming of the sequence or control the Electronic Load via GPIB. It takes several tens milliseconds for proc
16、essing time when the output of PBX series is turned ON or OFF. Pay attention to the execution time per step when using the output ON/OFF function in the normal speed sequence operation. When the execution time per step is less than about100 ms, the step may not be executed in the setting time. Norma
17、l speed modeFast speed mode Availabe output (Mode)NV mode and NI modeFV mode and FI mode Execution time per step1. Millisecond range (0, 1ms to 9999ms)0.1ms to 100.0ms (Time unit)2. Second range (0, 0.1s to 999.9s) 3. Minute range (0, 1s to 999min 59s)(Per step; fixed time) 4. Hour range (0, 1min to
18、 999h 59min) (Can be set as required for each step within the same range) (Execution time 0 means that the step is to be skipped.) Type of output changeStep change or ramp changeStep change Trigger input/output functionAvailableAvailable (TRIG I/O terminal)(Select either trigger input or trigger out
19、put.)(Trigger output only) Output ON/OFFAvailableUnavailable (To be kept in the ON state) Pause functionAvailableUnavailable Maximum number of steps2561024 Number of loops1 to 9998, and infinitive (by specifying 9999)1 to 9998, and infinitive (by specifying 9999) Number of sequences88 Number of prog
20、rams1616 Caution Chapter 3. OPERATING METHOD 3-66 Voltage offset calibration (manual) + full-scale voltage calibration (manual) RMS display offset calibration (auto) RMS display full-scale calibration (auto) 8: Interface : Interface board setting menu 1: GPIB Address : For GPIB address setting 2: MC
21、B Address : For MCB bus address setting 3: RS-232C Speed : For transmission speed selection 1: 9600 bps 2: 4800 bps 3: 2400 bps 4: 1200 bps 4: RS-232C Data bit : For data bit size selection 1: 8 bits 2: 7 bits 5: RS-232C Stop bit : For stop bit size selection 1: 1 bit 2: 1.5 bits 3: 2 bits 6: RS-232
22、C Parity : For parity bit selection 1: None 2: Odd 3: Even 7: Power-on SRQ : For power-on service request selection 1: Disable 2: Enable 9: Calibration : Calibration menu (Setting for calbiration is necessary.) 1: Voltage : For voltage calibration Current offset calibration (manual) + full-scale cur