lecroy 93XXC-OM-E19 电路图.pdf
《lecroy 93XXC-OM-E19 电路图.pdf》由会员分享,可在线阅读,更多相关《lecroy 93XXC-OM-E19 电路图.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、$? $SSHQGL?$?6SHFLILFDWLRQV $ ? ?7?LQSXW?ZLWK?( Slope, Level and Coupling able to be set independently Slope: Positive, Negative, Window (Bislope) Coupling: AC, DC, HF (up to 500 MHz), LFREJ, HFREJ Pre-trigger Recording: 0100 % of full scale adjustable in 1 % increments RadioFans.CN 收音机爱 好者资料库 $? ?
2、frequency above 50 Hz; Duty cycle greater than 0.1% Autosetup Time: Around two seconds Vertical Find: Automatically sets sensitivity and offset ?3UREHVProbe Model: One PP002 probe supplied per channel; FET probes, purchased separately, fully compatible with entire scope series Probe calibration: Max
3、 1 V into 1 M, 500 mV into 50 , frequency and amplitude programmable, pulse or square wave able to be selected, rise and fall time 1 ns typical (calibrator also offers trigger or Pass/Fail output) RadioFans.CN 收音机爱 好者资料库 $? 6SHFLILFDWLRQV 6LJQDO?9LHZLQJ LVSODCRT: 12.5 x 17.5 cm (9” diagonal) raster
4、Resolution: 810 x 696 points Grids: 1, 2, or 4 grids. Formats: YT, XY and both together Graticules: Internally generated; separate intensity control for grids and waveforms Waveform Style: Vectors, which can be switched on and off, connect individual sample points highlighted as dots Modes: Normal,
5、XY, Variable or Infinite Persistence Real-time Clock: Date, hours, minutes, seconds Vertical Zoom: Up to 5x Vertical Expansion (50 x with averaging, up to 40 V sensitivity) Horizontal Zoom: ModelZoom Factor 9304C9310C9314C1000 x 9304CM9310CM9314CM5000 x 9310CL9314CL20 000 x 6LJQDO?$QDOVLV :DYHIRUP?3
6、URFHVVLQJProcessing Functions: Add, Subtract, Multiply, Divide, Negate, Identity and Summation Averaging; four functions performable at one time Average: Summed averaging of up to 1000 waveforms in the basic instrument; up to 106 averages possible with optional WP01 Advanced Waveform Math Package Ex
7、trema: Roof, Floor or Envelope values of from 1 to 106 waveforms with optional WP01 Advanced Waveform Math Package $? ? sampled data always available, even when trace turned off; any of above modes usable without destroying data with WP01 Option FFT: Spectral Analysis with five windowing functions a
8、nd FFT averaging, with optional WP02 Spectrum Analysis Package Histogramming and Trending: With optional WP03 Parameter Analysis Package, in-depth diagnostics on waveform parameters ,QWHUQDO?0HPRUWaveform Memory: Up to four 16-bit Memories (M1, M2, M3, M4) Processing Memory: Up to four 16-bit Wavefo
9、rm Processing Memories (A, B, C, D) Setup Memory: Four non-volatile memories; optional cards for high- capacity waveform and setup storage command language compliant with IEEE-488.2 Centronics Port: Hardcopy interface PC Card (PCMCIA II/III Ports): Optional for memory cards, flash cards and removabl
10、e hard disks Floppy Disk: High density 3.5-inch floppy disk drive (DOS format) Hardcopy: TIFF and BMP formats available for import to Desktop Publishing programs; printers and plotters HP DeskJet, HP ThinkJet, QuietJet, LaserJet, PaintJet, and EPSON printers; HP 7400 and 7500 series, or HPGL compati
11、ble plotters $? 6SHFLILFDWLRQV ? Optional internal, high-resolution graphics printer Output Formats: Binary, or ASCII waveform output compatible with spreadsheets, MATLAB, MathCad *HQHUDOAuto-calibration: Ensures specified DC and timing accuracy Temperature: 5 to 40 C (41 to 104 F) rated Humidity: 8
12、0 % for temperatures up to 31 C, decreasing linearly to 50 % relative humidity at 40 C Altitude: Up to 2000 m (6560 ft) operating, 40 C max Power: 90250 V AC, 4566 Hz, 150 W Battery Backup: Front-panel settings maintained for two years Dimensions: (HWD) 8.5 x 14.5 x 16.25 inches / 264 x 397 x 453 mm
13、 Weight: 12.5 kg (27.5 lb.) net, 18 kg (40 lb.) shipping Warranty: Three years UL and cUL listed, File E 170588: Protection Category I, Installation (Over-Voltage) Category II, Pollution Degree 2 See Declaration of Conformity for further details. $? ? 50 000 points: 101000 s/div External Clock: ?0+?
14、RQ?(;7?LQSXW?ZLWK?( Slope, Level and Coupling able to be set independently Slope: Positive, Negative Coupling: AC, DC, HF (up to 500 MHz), LFREJ, HFREJ Pre-trigger Recording: 0100 % of full scale adjustable in 1 % increments Post-trigger Delay: 010 000 divisions adjustable in 0.1 div increments Hold
15、off by Time: 10 ns20 s Holdoff by Events: 099 999 999 events Internal Trigger Range: 5 div EXT Trigger Max Input: ? 50 1 %: 5 V DC (500 mW) or 5 V rms ? 1 M/15 pF: 250 V max. (DC + peak AC 10 kHz) EXT Trigger Range: 0.5 V (5 V with Ext/10) Trigger Timing: Trigger Date and Time listed in “Memory Stat
16、us” menu 60$57?7ULJJHU?7SHVSignal or Pattern Width: Triggers on width between two limits of between 2.5 ns and 20 s Signal or Pattern Interval: Triggers on interval between two limits of between 10 ns and 20 s Dropout: Triggers if the input signal drops out for a time-out longer than 25 ns20 s State
17、/Edge Qualified: Triggers on any source only if a given state or transition number of events, time interval on another source TV: Selection of both line (up to 1500) and field number (up to 8) for PAL, SECAM, NTSC or nonstandard video Exclusion Trigger: Triggers only on shorter-than-normal (defined)
18、 aberrations Pattern Trigger: ? Two-channel models: Triggers on the logic combination of the three inputs CH 1, CH 2 and EXT Trigger, where each source can be defined as High, Low or Dont Know and the trigger as the patterns beginning or end ? Four-channel models: Triggers on the logic combination o
19、f the five inputs CH 1, CH 2, CH 3, CH 4 and EXT Trigger, where each source can be defined as High, Low or Dont Know and the trigger as the patterns beginning or end $? ? frequency above 50 Hz; duty cycle greater than 0.1% Autosetup Time: Around two seconds Vertical Find: Automatically sets sensitiv
20、ity and offset ?3UREHVProbe Model: One PP002 probe supplied per channel, DC to 250 MHz typical at probe tip, 600 V max.; FET probes, purchased separately, fully compatible with entire scope series Probe calibration: Max 1 V into 1 M, 500 mV into 50 , frequency and amplitude programmable, pulse or sq
21、uare wave able to be selected, rise and fall time 1 ns typical (calibrator also offers trigger or Pass/Fail output) 6LJQDO?9LHZLQJ LVSODCRT: 12.5 x 17.5 cm (9” diagonal) raster Resolution: 810 x 696 points Grids: 1, 2, or 4 grids. Formats: YT, XY and both together Graticules: Internally generated; s
22、eparate intensity control for grids and waveforms Waveform Style: Vectors, which can be switched on and off, connect individual sample points highlighted as dots Modes: Normal, XY, Variable or Infinite Persistence Real-time Clock: Date, hours, minutes, seconds Vertical Zoom: Up to 5x Vertical Expans
23、ion (50 x with averaging, up to 40 V sensitivity, with optional WP01 Advanced Waveform Math Package) Horizontal Zoom: Waveforms can be expanded to give 22.5 points/div ModelZoom Factor 9344C9350C9354C2000 x 9344CM9350CM9354CM10 000 x 9354CTM50 000 x 9344CL9350CL9354CL100 000 x $? 6SHFLILFDWLRQV 6LJQ
24、DO?$QDOVLV :DYHIRUP?3URFHVVLQJProcessing functions: Add, Subtract, Multiply, Divide, Negate, Identity, Summation Averaging, and Sine x/x; four functions performable at one time Average: Summed averaging of up to 1000 waveforms in the basic instrument; up to 106 averages possible with optional WP01 A
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- lecroy 93XXC-OM-E19 电路图 93 XXC OM E19
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf