leader_lbo-516_delayed_time-base_100_mhz_oscilloscope_operation 电路图.pdf
《leader_lbo-516_delayed_time-base_100_mhz_oscilloscope_operation 电路图.pdf》由会员分享,可在线阅读,更多相关《leader_lbo-516_delayed_time-base_100_mhz_oscilloscope_operation 电路图.pdf(33页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ENJOY YOUR BOOKS PLEASE VISIT OUR STORE FOR EVEN MORE GREAT STUFF! WWW.EVERYTHING4LESSSTORE.COM COPYRIGHT NOTICE ALL MATERIALS INCLUDING CD/DVD AND PDF FILES ARE COPYRIGHTED WWW.EVERYTHING4LESSSTORE.COM VON WALTHOUR PRODUCTIONS AND MAY NOT BE REPRODUCED, COPIED OR RESOLD UNDER ANY CIRCUMSTANCES. YO
2、U MAY HOWEVER MAKE A COPY FOR YOUR OWN PERSONAL BACKUP. MATERIALS ARE FOR PERSONAL USE ONLY. IF YOU PURCHASED THIS FROM ANYWHERE BUT FROM US PLEASE NOTIFY US IMMEDIATELY SO THAT WE MAY CHECK IF YOU PURCHASED FROM AN AUTHORIZED RESELLER SO WE CAN LET YOU KNOW IF YOU NEED TO RETURN FOR FULL REFUND FRO
3、M AN UNAUTHORIZED SELLER. THANKS AGAIN AND PLEASE TAKE THE TIME TO VISIT OUR STORE. ATTENTION! EVERYTHING ON SALE NOW! RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 WARNING! THE SERVICING INSTRUCTIONS CONTAINED IN THIS MANUAL ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK, DO NOT
4、 PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO. RadioFans.CN 收音机爱 好者资料库 LBO-516 100 MHz DELAYED TIME BASE OSCIILOSCOPE TABLE OF CONTENTS 1. GENERALINFORMATION.1 1-1 INTRODUCTION .1 1-2 SPECIFICATIONS .1 2. OPERATING INSTRUCTIONS.3 2-1
5、 FUNCTION OF CONTROLS, CONNECTORS, AND INDICATORS . 3 2-1-1 Display Block . 3 2-1-2 Vertical Amplifier Block . 4 2-1-3 Sweep and Trigger Blocks . 5 2-1-4 Miscellaneous . 7 2-2 INITIAL OPERATION . 7 2-2-1 Power Connections and Adjustments . 7 2-2-2 Installation . 8 2-2-3 Preliminary Control Settings
6、and Adjustments . 8 2-3 BASIC OPERATING PROCEDURES . 9 2-3-1 Signal Connections . 9 2-3-2 Single-trace Operation .11 2-3-3 Triggering Alternatives .11 2-3-4 Probe Compensation .14 2-3-5 Dual-trace Operation .15 2-3-6 Additive and Differential Operation .16 2-3-7 Triple-trace Operation .17 2-3-8 Four
7、-trace Operation .17 2-3-9 Delayed Timebase Operation .18 2-3-10 Single-shot Operation .20 2-3-11 X-Y Operation .20 2-3-12 Intensity Modulation .20 2-4 MEASUREMENT APPLICATIONS .21 2-4-1 Amplitude Measurements .21 2-4-2 Differential Measurement Techniques .22 2-4-3 Time Interval Measurements .23 2-4
8、-4 Phase Difference Measurements .24 2-4-5 Distortion Comparison .26 2-4-6 Frequency Measurements .27 2-4-7 Risetime Measurements .27 2-4-8 -3dB Bandwidth Measurement .28 1. GENERAL INFORMATION 1-1. INTRODUCTION The LBO-516, shown in Figure 1-1, is a 100 MHz oscilloscope with all of the features nor
9、mally found on a lab-grade scope: high- fidelity pulse response, stable operation, dual timebase with calibrated sweep delay, flexible triggering facilities, and a bright CRT display with illuminated internal graticule. Moreover, it also has a very unusual feature found on few scopes in any price cl
10、ass: it can simultaneously display up to eight traces from three different input signals! In addition to the two vertical-input channels and their differ- ence signal, the signal used to externally trigger the main timebase can also appear on the CRT display. The alternate sweep mode, which allows t
11、he main and delayed timebases to simultaneously sweep the CRT, effectively doubles this four-trace display to an eight-trace display. The comprehensive triggering facilities of the LBO-516 include several features that ease the problem of triggering on complex signals: a variety of frequency-selecti
12、ve coupling filters, a trigger holdoff-control, and a trigger pickoff that alternates between the two vertical channels. 1-2. SPECIFICATIONS Specifications for the model LBO-516 oscilloscope are given in Table 1-1. Table 1-1 SPECIFICATIONS Vertical Amplifiers (Ch. 1 -+5% with Xl0magniflca-tion 1 meg
13、ohm +-2%, 25 pF +-3 pF Maximum Input Voltage 400 V (DC plus AC peak) 1 Signal Delay Leading edge displayed. Leading edge displayed. CH-1 only, CH-2 only, CH-1 use this as a guide in de- termining whether or not to add the additional 90. 10. The sine-to-angle conversion can be accomplished by using t
14、rig tables or a trig calculator. However, if the sine is between 0.1 and 1.0, you can use the Figure 2-21 nomograph. Simply lay a ruler on the nomograph so its edge passes through the cross mark and the number of divisions measured in Step 7 (B dimension). When this is done the edge will also inters
15、ect the phase-angle column. 2-4-5 Distortion Comparison The dual-trace feature of the LBO-516 offers a quick method of checking for distortion caused by a signal-processing device (such as an amplifier). To do this, proceed as follows: 1. Connect the output of the signal generator (of frequency suit
16、able to the device under test) to the CH- 1 IN connector (14) and the input of the device under test (DUT). 2. Connect the CH-2 IN connector (15) to the output of the device or its load (see Figure 2-22) 3. Increase the signal to the DUT until the channel 2 trace or an RMS AC voltmeter indicates the
17、 desired output level. 4. If the DUT has reversed the phase, press the CH-2 INV pushbutton (19). 26 5. Superimpose the two traces with the vertical POSITION controls (17) and (18), and use the VARIABLE VOLTS/ DIV control (11) of the larger trace to achieve the best trace match. 6. Any uniform horizo
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- leader_lbo-516_delayed_time-base_100_mhz_oscilloscope_operation 电路图 leader_lbo 516 _delayed_time base_100_mhz_oscilloscope_operation
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-203003.html



Marshall-9100-62-02-Schematic电路原理图.pdf
西门子 Siemens 312 电路原理图.gif
Telefunken 314 电路原理图.jpg