krohnhite Model3500 电路图.pdf
《krohnhite Model3500 电路图.pdf》由会员分享,可在线阅读,更多相关《krohnhite Model3500 电路图.pdf(28页珍藏版)》请在收音机爱好者资料库上搜索。
1、SOLID STATE BAND-PASS FILTER MODEL 3500 SERIAL NO. OPERATING AND MAINTENANCE MANUAL KROHN-HITE CORPORATION AVON INDUSTRIAL PARK I 255 BODWELL STREET I AVON, MA. 02322 TEL. (617) 580-1660 TWX 710-345-0831 1984 RadioFans.CN 收音机爱 好者资料库 Contents Section I 2 3 4 5 6 Figure I 2 3 4 5 6 7 8 9 10 I I CONTEN
2、TS GENERAL DESCRIPTION OPERATION. CIRCUIT DESCRIPTION INCOMING ACCEPTANCE AND INSPECTION MAINTENANCE CALIBRATION AND ADJUSTMENT . ILLUSTRATIONS Model 3500 Filter Normalized Frequency Square Wave Response Normalized Attenuation Characteristics Normalized Phase Characteristics Front and Rear Panels Si
3、mplified Schematic Diagram Test Point Voltages Top and Side View of Chassis Schematic Diagram PC307 Page I 7 9 12 15 19 Page ii 3 4 4 5 6 9 16 18 Foldout Foldout i RadioFans.CN 收音机爱 好者资料库 Filter 3500 Model 3500 . Figure 1. Model 3500 Filter ii RadioFans.CN 收音机爱 好者资料库 Section 1 -General Description S
4、ECTION 1 GENERAL DESCRIPTION 1.1 INTRODUCTION The Model 3500 Filter, shown in Figure 1, is a variable, electronic band-pass filter that operates at frequencies from 20Hz to 200kHz. The filter consists basically of an input amplifier, a variable high-pass section, a variable low-pass section, and an
5、output amplifier. The high-pass and low-pass sections are con nected in series. The overall gain of the Filter is unity(Odb). The cutoff frequencies of both the high -pass and low-pass sections can be adjusted independently over the full frequency range of 20Hz to 200kHz. An optional rack-mounting k
6、it, (Part No. RK-38) is available from Krohn-Hite, for installing the unit in a standard 19 rack spacing. 1.2 GENERAL SPECIFICATIONS Frequency Range Continuous coverage from 20Hz to 200kHz for both high cut-off and low cut-off fre quencies independently. Frequency range is covered by separate calibr
7、ated dials and four-decade band switches. Center frequency and width of pass band in band pass.mode are continuously adjustable over the entire frequency range. BAND MULTIPLIER FREQUENCY (Hz) 1 1 20 -200 2 10 200 -2, 000 3 100 2, 000 -20, 000 4 lK 20, 000 -200, 000 Frequency Dials Each dial is engra
8、ved and individually hand-calibrated with a single logarithmic scale reading directly in cycles per second, from 19 to 210. Dials are 2 inches in diameter with an effective scale length of 6 inches per band, giving a total effec tive scale length of 24 inches for the range of 20Hz to 200kHz. Accurac
9、y of Cut-off Frequency Calibration 10% with Response switch in max-flat (Butterworth) position; les s accurate in Low QII position. Relative to mid-band level, the filter output is down 3db at cut off in max-flat position, and approximately 12db in II Low Q position. Filter, 3500 Bandwidth Continuou
10、sly va r ia bl e within the cutofffrequencylimits of 20Hz and 200kHz. For minimum pass -band (Butterworth response) the two cutoffs are set to the same frequency, resulting in an insertion los s of 6db at that frequency, with 3db points at factor s of .8 below it and 1. 25 above it. Response Charact
11、eristi cs Choice of 4 pole Butterworth (maximally flat response) for frequency domain opera tion and Low Q (damped response) for transient-free time domain operation, se lected by means of a switch on rear of chassis. Pass-Band Gain Zero db l db in pass band. Input Characteri sti cs. Impedan ce Appr
12、oximately 10 megohms in parallel with 50 pf. Maximum input amplitude: 5 volts rms up to 2MHz. Maximum dc component: 00 volts. Output Characteristics, Impedance Approximately 50 ohms. Maximum Voltage +7 volts peak. Maximum Current +5 rna peak. Internally generated hum and noise: Less than 200 microvo
13、lts. (Slightly higher for 400 Hz operation. ) Attenuation Slope Nominal 24db per octave each side of pass-band. Maximum Attenuation Greater than 60 db. Controls Front panel; LOW CUT-OFF FREQUENCY dial and multiplier switch. HIGH CUT OFF FREQUENCY dial and multiplier switch. POWER OFF-ON switch. Rear
14、 panel; RESPONSE switch, GROUND switch, 115/230V LINE switch. Terminals Front panel, two BNC connectors, one for INPUT and one for OUTPUT. Rear of chassis, two BNC connectors, one for input and one for output. An additional multi purpos e binding post for CHASSIS GROUND is provided on the rear panel
15、. An AC power receptacle with detachable line cord is also provid ed. Power Requirements 105-125 or 210-250 volts, single phase; 50-400 Hz, 10 watts. Hum and noise are increased by a factor of approximately two for 400Hz operation. 2 Section I -General Description Fuse Protection 1/8 ampere slow-blo
16、w for 11 5 volts, 1/16 ampere slow-blow for 230 volts. Dimensions and Weights Model Overall Dimen sion s (inc hes) W e ig ht (lb s.) 3500 8 1/2 wide I 3 1/2 high I 13 deep 9 net 114 shipping 1.3 FILTER CHARACTERISTICS Bandwidth Adjustment The flexibility of adjustment of bandwidth is illustrated in
17、Figure 2. Band-pass operation in the MAXimally FLAT or Butterworth m od e for two different barid wid th s is illustrated by cu r ve s A and B. Cu rve B sh ows the minimum pa ss-band width obtained by setting the two cut off frequencie s equal. In this cond ition the insertionlossis 6db, andthe - 3
18、dbcutofffrequencies oc cu r at0.8and 1.25 timesthemid-bandfrequency. Theminimumpass-bandfora 0dbinsertionloss is s hown by cu r ve A with the cutoffs s et at 0.5 and 2 times the mid - ban d frequency. 0 -6 -10 :0 :g -20 z 0 - 30 : -40 z w -50 I -60 -70 -80 .01 .02 .04 .06 .1 .2 .4.6 2 4 6 10 20 4060
19、 100 fI . A V I 8 , 1 / J If , 1 / / , / I 1 I V i / 1/ / NORMALIZED FREQUENCY Figure 2. Normal iz ed Frequency Transient Response Thefrequencyresponsecha r acte r i s ticofthisFiltercloselyapproximates afourth order Butterworth with m ax im al flatnes s, id eal for filtering in the frequency do m a
20、 in. For puls e o r transient s ignal filtering, a r e sponse switch is p r ovid ed to change the frequency re sponse to Low 0, optim um for transient-free filte r ing. Figure 3 shows a comparison of th e Filter output response in the se modes to a squa r e wave input signal. 3 Filter, 3500 (A) (E)
21、Figure 3. Square Wave Respon s e Cutoff Response The attenuation cha r a cteristics of the Filter are shown in F ig u re 4. With the r e sponse s w itch in the MAXimally FLAT o r Butterworth m ode, the gain, a s shown by the solid cu rve , is virtually flat until the -3db cutoff frequency. At approx
22、i m a tel y twotim e s thecutofffrequencytheattenuationratecoin c id es with th e 24 db per octave straight line a s ymptote. In the Simpl e R C m ode, optimum for tran s ien t - f r e e filtering, the dotted line show s that the ga in i s down approx imately 12 dbatcutoffandr e aches 24 dbperoctav
23、e attenuationrate a t fivetim e s thecutoff frequency. Bey ond thi s frequency the filter attenuation r a t e and max i mum attenua tion, in either m od e, are identi c al, o - 6 -12 CD 3 A .5 .6.7 89 I21 3 4 5 6 789102 f L OR.b. fH f 1-_-. r-. r-.I 1, 1r-. i I I I I 1 I I f H =HIGH CUTOFF FREQUENCY
24、 . I I f l = lOW CUTOFF FREQUENCY . I I I I I J a - 18 l: o a: -24 -.J LL - 3 0 -36 -42 Figure 4. Normalized Atte n uation Characteristics 4 Section 1 -General Description Phase Response The phase angle at any frequency is the sum of the angles due to the high-pass and low-pass sections of the Filte
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- krohnhite Model3500 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf