lecroy 08_LTXXX-OM-E_Ch4 电路图.pdf
《lecroy 08_LTXXX-OM-E_Ch4 电路图.pdf》由会员分享,可在线阅读,更多相关《lecroy 08_LTXXX-OM-E_Ch4 电路图.pdf(10页珍藏版)》请在收音机爱好者资料库上搜索。
1、44ISSUED: January2002LTXXX-OM-E Rev B CH A P T E RFO U R:ChooseaMeasureTool Inthis chapter, see how Tocontroltime cursors Tocontrolamplitude cursors Touse cursors instandard display Toselect a standard parameter RadioFans.CN 收音机爱 好者资料库 LTXXX-OM-E Rev BISSUED: January200245 CH A P T E RFO U RChooseaM
2、easureTool MeasurewithCursors Cursors areimportant tools that aidyouinmeasuringsignal values. Cursors aremarkers lines, cross-hairs, or arrows that youcanmovearoundthegridor thewaveform itself. Usecursors tomakefast, accurate measurements andtoeliminateguesswork. Therearetwobasic types: Time (Freque
3、ncy)cursors aremarkers that youmovehorizontallyalongthewaveform. Placethem at a desiredlocationalongthetimeaxis toreadthesignals amplitudeat theselectedtime. Amplitude (Voltage)cursors arelines that youmoveverticallyonthegridtomeasuretheamplitudeof a signal. CONTROL THE TIME CURSORS 1.Press DISPLAY
4、andmakesurethat Standard is selectedinthetopmenu. 2.Press MEASURE TOOLS todisplaytheMEASURE menus. T TI IP P: : Press SINGLE as a smoothwaytostopyour Waverunnerscope and allowmeasurement of the displayed waveform. 3.Press thebuttontoselect 4.Press thebuttontoselect 5.Press thebuttontoselect RadioFan
5、s.CN 收音机爱 好者资料库 PA R TON E:G E T T I N GS T A R T E D 46ISSUED: January2002LTXXX-OM-E Rev B 6.TurntheknobfortomovetheAbsoluteTimecursor. Watchthiscross-hair marker moveupanddownalongyour displayedwaveform.Asit moves,thecursorstimevalue inrelationtothetrigger point isshownbeneaththegrid,anditsvoltage
6、valueinthetracelabel. 7.Press thebuttontoselectT TI IP P: :Select“Diff measured times are relative to the trigger point. InRelativemode, you control a pair of amplitude or time cursors, and get readings on the difference between the two in amplitude, or time and amplitude. WH E N INPE RSIST E N CEMO
7、DE In persistence mode, amplitude cursors are the same as in Standard display, while time cursors are vertical bars running down the screen and moving across it. T TI IP P: : Toset time-cursoramplitude units involts ordecibels. Press UTILITIES toaccess and select SpecialModes. Then select the Cursor
8、s Measure menu toaccess and use the Read time cursoramplitudes inmenu toselect the desired unit. PA R TON E:G E T T I N GS T A R T E D 50ISSUED: January2002LTXXX-OM-E Rev B MeasureAutomaticallywithParameters Parameters aremeasurement tools that determineawiderangeof signal properties. Usethem to aut
9、omatically calculatetimeandvoltagevalues. Thereareparameter modes for theamplitudeandtimedomains, custom parameter groups, andparameters for pass andfail testing. Youcanmakecommonmeasurements on one signal ineither thestandardvoltage(amplitude)or standardtimemodes. Onmorethan onesignal, select param
10、eters from aCustom categoryandusethem todetermineuptofivequantities at once. Pass andfail parameters canbecustomized, too. Youcanaccumulateanddisplaystatistics oneachparameters sweeps, average, lowest, highest andstandarddeviation. SeeChapter 11, “Parameter Analysis,” for howto customizeparameters,
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- lecroy 08_LTXXX-OM-E_Ch4 电路图 08 _LTXXX OM E_Ch4
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


