1、LTXXX-OM-E Rev BISSUED: January2002191 CH A P T E RFO U R T E E NMaking Histograms CreateandViewaHistogram Createyour histogram as youwouldanyother Mathfunction: bydefiningtraceA, B, C, or D as thefunction. Havingconnectedyour signal toaWaverunner channel (Channel 1 inthis example), dothefollowing:
2、1.Press 1 toselect CHANNEL 1 anddisplaythebasic Waverunner menus. 2.Press thebuttontoand A tomakeTraceA azoom of Channel 1. 3.Press thebuttonforandselecttodisplaySETUP OF A. 4.Usetheseandthemenus onthefollowingpages to set upyour histogram. Toselect for math. Toselect Histogram. Toselect parameters
3、andfurther configurethehistogram (seenext page). For calculatingoptimal center- andbin-widthvalues for the histogram. Toselect theparameter linetobeusedinthehistogram. Toselect usingbutton or knob thenumber of values inthehistogram. Whenthemaximum of two billionvalues is exceeded, theparameter resul
4、ts will scroll off thehistogram. RadioFans.CN 收音机爱 好者资料库 H I S T O G R A M S 192ISSUED: January2002LTXXX-OM-E Rev B T TI IP P: : As withanyothertrace, position and expand yourhistogramusing POSITION and ZOOM knobs POSITION ZOOMZOOM POSITION Toadjust either thehistogram binningor scalesettings. When
5、Binning is selected, themenus shown hereappear. N NO OT TE E: : Whenusing these knobs, values inthe “Center” and “Width” menus do not change, since theydetermine the range of the histogramand cannot be used todetermine the parametervalue range of a particularbin. If the histogramis repositioned usin
6、g the horizontalPOSITION knob the histograms centerwillbe moved fromthe centerof the screen. (MEASURE TOOLS should thenbe used. ) Toaccess theCHANGE PARAM menus andselect or configurea parameter for histogramming. SeeChapter 11, “Parameter Analysis.” For calculatingoptimal center- andbin-widthvalues
7、 for the histogram. For choosingthenumber of bins intowhichthe parameter events aretobeclassified, or distributed. RadioFans.CN 收音机爱 好者资料库 CH A P T E RFO U R T E E N:Making Histograms LTXXX-OM-E Rev BISSUED: January2002193 Toadjust either thehistogram binningor scalesettings. WhenScale is selected,
8、themenus shownhereappear (seepage197). For settingtheverticalscale: Linearsetsalinear verticalscale,Log a logarithmicverticalscale,and LinConstMaxtheverticalscalingtoa linear valuethat usesclosetothefullverticaldisplaycapabilityof the instrument. Waverunner automaticallyincreases thevertical scalese
9、ttingas required, ensuringthat thehighest histogram bar does not exceedthe vertical screendisplaylimit. Toselect parameters andconfigurethehistogram. For calculatingoptimal center- andbin-widthvalues for the histogram. Toset thehistogram center value. Toset thehistogram widthvalueper division. The w
10、idthper divisionmultipliedbythenumber of horizontal displaydivisions (ten)determines therange of parameter values centeredonthenumber inthe “Center” menu, usedtocreatethehistogram. RadioFans.CN 收音机爱 好者资料库 H I S T O G R A M S 194ISSUED: January2002LTXXX-OM-E Rev B Figure2.1, below , shows thedisplayw
11、hen“Histogram” is selectedfrom the“MathType” menu. Thefreq parameter onlyhas beendefined. Todefineadditional parameters, select from the“Histogram custom line” menu. Figure 2.1 Eachtimeawaveform parameter valueis calculatedyoucanplaceit inahistogram bin. Themaximum number of suchvalues is selectedfr
12、om the“usingupto” menu. Pressingtheassociatedmenubuttonor turningthe knoballows youto select arangefrom 20 totwobillionparameter valuecalculations for histogram display. CH A P T E RFO U R T E E N:Making Histograms LTXXX-OM-E Rev BISSUED: January2002195 5.Now , press A todisplaythehistogram, for adi
13、splaysimilar tothat showninFigure2.2. 2 1 Figure 2.2 Eachhistogram is set tocaptureparameter values fallingwithinaspecifiedrange. As thescopecaptures the values inthis rangethebincounts will increase. Thosevalues not fallingwithintherangearenot usedinthe histogram. Informationonthehistogram is provi
14、dedintheDisplayedtracefield(Item )for theselectedtrace, which shows: Thecurrent horizontal per divisionsettingfor thehistogram (“1 Hz” inthis example). Theunit typeused is determinedbythewaveform parameter typeonwhichthehistogram is based. Thevertical scalein#bincounts per division(here, “200 m”). T
15、henumber of parameter values that fall withintherange(“inside0”) Thepercentagethat fall below(“0%”) Thepercentageof values abovetherange(“100%”). H I S T O G R A M S 196ISSUED: January2002LTXXX-OM-E Rev B Theprevious figureshows that 100% of thecapturedevents areabovetherangeof binvalues set for the
16、 histogram. As aresult, thebaselineof thehistogram graph ()is displayed, but novalues appear. Selectingthe“FIND CENTER AND WIDTH” menucalculates theoptimal center andbin-widthvalues, basedontheup-to-the-most-recent parameter values calculated. Choosethenumber of parameter calculations with the“using
17、upto” menu(or 20 000 values if this is greater than20 000). Figure2.3 shows atypical result. 1 Figure 2.3 If thetraceonwhichyouhavemadethehistogram is not azoom, all bins withevents will bedisplayed. Otherwise, youcanpress RESET toreset thetraceanddisplayall histogram events. TheInformation Window(I
18、tem )at thebottom of theprevious figureshows ahistogram of thefreq parameter for Channel 1 (designatedas “A:Hfreq(1)”)for TraceA. The“1000 100 pts” inthewindow indicates that thesignal onChannel 1 has 1000 waveform acquisitionsamples per sweepandis beingmapped into100 histogram bins. SETTING BINNING
19、 AND SCALE The“Setup” menuallows modificationof either the“Binning” or thehistogram “Scale” settings. If “Binning” is selected, the“classifyinto” menuappears, as showninthefigureabove. CH A P T E RFO U R T E E N:Making Histograms LTXXX-OM-E Rev BISSUED: January2002197 Thenumber of bins usedcanbeset