KEPCO ABC-DM Series Operator 电路图.pdf
《KEPCO ABC-DM Series Operator 电路图.pdf》由会员分享,可在线阅读,更多相关《KEPCO ABC-DM Series Operator 电路图.pdf(92页珍藏版)》请在收音机爱好者资料库上搜索。
1、IMPORTANT NOTES: 1)This manual is valid for the following Model and associated serial numbers: MODELSERIAL NO.REV. NO. 2)A Change Page may be included at the end of the manual. All applicable changes and revision number changes are documented with reference to the equipment serial num- bers. Before
2、using this Instruction Manual, check your equipment serial number to identify your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu- mentation Office in New York, (718) 461-7000, requesting the correct revision for your par- ticular model and serial number. 3)The cont
3、ents of this manual are protected by copyright. Reproduction of any part can be made only with the specific written permission of Kepco, Inc. Data subject to change without notice. KEPCO THE POWER SUPPLIER MODEL OPERATORS MANUAL KEPCO INC. ORDER NO.REV. NO. KEPCO, INC. ? 131-38 SANFORD AVENUE ? FLUS
4、HING, NY. 11352 U.S.A. ? TEL (718) 461-7000 ? FAX (718) 767-1102 email: ? World Wide Web: ABC-DM SERIES SWITCHING POWER SUPPLY VOLTAGE/CURRENT-STABILIZED DC SOURCE ABC-DM SERIES POWER SUPPLY 1996, KEPCO, INC P/N 243-0888 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 ABCCOND012703A These instructio
5、ns are a quick reference for getting started with Kepcos ABC power supply. For more detailed information you are encouraged to read the accompanying Operators Manual. CONNECT THE LOAD. The Sense terminals must be connected for the power supply to work. For local sensing use the links supplied on the
6、 barrier strip at the rear. For remote sensing, remove the links and make the 4-wire connections at your load. (See the Oper- ators manual for more information.) CONNECT SOURCE POWER. The power supply accepts a wide range of source power: 85-264V a-c, 47-63 Hz or 400Hz. The POWER switch turns the un
7、it on and off. The power supply is equipped with a grounded North American 2-blade plug. Overseas users may substitute their national plug; the chassis end is a standard 15A IEC connector. LOCAL OPERATION THE ALPHANUMERIC DISPLAY (LCD). Operations are done from the keypad and observed on the LCD. Op
8、timize LCD contrast by pressing MENU once, then press numbers until viewing is optimum. The LCD displays the actual output voltage and current and the operating mode: Local or Remote and constant voltage (CV) or current (CC). and a blinking colon (:), or a blinking equal sign (=). Enter a command wh
9、en you see a blinking colon (:), enter numbers when you see a blinking equal sign (=). Six keys have a dual function (command/number): the blinking colon (:) or equal sign (=) tells you which key function is effective. USING THE KEYPAD. Use ENTER to accept numbers entered or execute a command. Use C
10、LEAR if you make a mistake and dont want to change the status quo. Valid entries are accompanied by a short beep; invalid entries by a longer buzz. (The speaker can be disabled by pressing MENU three times and entering 0.) OUTPUT SETTINGS. V SET sets output voltage; I SET sets output current. Depend
11、ing on the mode (CV or CC), one setting acts as a limit. (For example, in CC mode, V SET is the volt- age limit and I SET is the output current setting.) The operating mode (CC or CV) is determined by the load combined with the V SET and I SET settings. The ? and ? keys can be used to increase or de
12、crease output voltage (CV mode) or current (CC mode) by the least amount possible (approxi- mately the maximum rating divided by 4000). OUTPUT ON/OFF. (ON) enables programmed output settings to appear at the output (OFF) sets output voltage and current to zero and the LCD reads “Output is OFF” RESET
13、. Use RESET to restore the power-on defaults (output on, V SET and I SET at zero, OV SET and OC SET at approximately 10% above rated output). PROTECTION. OV SET and OC SET establish protection for overvoltage and overcurrent conditions. If the output attempts to exceed programmed OV SET or OC SET va
14、lues, the LCD indi- cates which condition occurred, and the output goes to zero. RESET or cycle the power supply off and on to recover. CALIBRATION. CALIB leads you through a digital calibration procedure (password pro- tected). The initial password is the voltage rating plus current rating (e.g., 1
15、010 for ABC 10-10DM). You can change it with using the MENU. The previous calibration is saved and can be restored. The original factory calibration can also be restored. (See Section 4 of the Operators Manual.) GETTING STARTED SIMPLIFIED OPERATING INSTRUCTIONS RadioFans.CN 收音机爱 好者资料库 BABCSVC012703
16、STORAGE LOCATIONS. Forty locations are available to either save active settings or to establish a local program that can be sequenced (EDIT PROG). STORE lets you save the active programmed settings (V SET, I SET, OV SET and OC SET). Just select a location (from 1 to 40). RECALL applies the V SET and