1、Table of Contents 1 1 Digital Oscilloscopes5 Fundamentals of Digital Oscilloscopes and Waveform Digitizing6 The Benefits of Digital Oscilloscopes15 WavePro Color Oscilloscopes18 WavePro Selection Guide18 WavePro Specifications28 Waverunner-2 Series Color Oscilloscopes34 Waverunner-2 Selection Guide4
2、2 Waverunner-2 Upgrade Guide43 Waverunner-2 Specifications45 Waverunner Series Color Oscilloscopes50 Waverunner Series Selection Guide52 Waverunner Upgrade Guide53 LT364,LT364L,LT344,LT344L, LT342,LT342L ,LT322,LT22454 Literunner Digital Oscilloscopes58 Applying the Power of DSOs to High-speed Digit
3、al Design60 2 Digitizing Systems69 PXI Digitizers70 High Throughput Digitizers:The LSA1000 Series73 3 Analog Oscilloscopes79 Analog Oscilloscope Selection Guide81 LA35482 LA314/LA314H85 LA302/LA30388 The Analog Advantage91 4 Probes and Accessories97 Passive Probes PP002/PP005/PP006/PP062/PP063/PP065
4、99 Active Probes AP020/AP022103 Active Differential Probes AP033/AP034106 LeCroy Test and Measurement Products Table of Contents RadioFans.CN 收音机爱 好者资料库 2 TABLEOFCONTENTS LeCroy Test and Measurement Products Table of Contents (continued) High Voltage Differential Probes ADP300/ADP305108 Differential
5、 Probes AP031110 Differential Amplifiers DA1820A/DA1822A111 DA1850A/DA1855A113 DA1820A-PR2/DA1822A-PR2/DA1850A-PR2/DA1855A-PR2115 Differential Probe Pairs DXC100A116 DXC200117 DXC5100/DA101118 High Voltage Passive Probes PPE1.2kV/PPE2000/PPE4000/PPE20kV 119 Current Probes CP015/CP150120 AP011122 AP0
6、15123 General-Purpose Accessories125 Instrument Carts126 Carrying Cases127 5 Jitter and Timing Analysis131 Jitter and Timing Analysis132 Three Views of Jitter133 LeCroy Jitter (Models 374 and 264) L4 Mpt/ch;(Model 374 only) LT3644500 MHz500 MS/s -1GS/s 250 k/500k8.4 TFT LT364L4500 MHz500 MS/s -1GS/s
7、1 M/2 M8.4 TFT LT3444500 MHz500 MS/s 250 k8.4 TFT LT344L4500 MHz500 MS/s1 M8.4 TFT LT3422500 MHz500 MS/s250 k8.4 TFT LT342L2500 MHz500 MS/s1 M8.4 TFT LT3222500 MHz200 MS/s100 k8.4 TFT LT2244200 MHz200 MS/s100 k8.4 TFT LP1422100 MHz500 MS/s 100 k5.7 LCD CONTENTS Digital Oscilloscopes 5 1 CONTENTS Dig
8、ital oscilloscopes and waveform digitizers sample signals using a fast analog-to-digital converter (ADC).At evenly spaced intervals,the ADC measures the voltage level and stores the digitized value in high-speed dedicated memory. The shorter the intervals,the faster the digitizing rate,and the highe
9、r the signal frequency that can be recorded.The greater the resolution of the ADC,the better the sensitivity to small voltage changes.The more memory,the longer the recording time. What are the benefits of this digital technology? Multiple signals associated with intermittent and infrequent events c
10、an be captured and analyzed instantly. Complex problems can be quickly identified by viewing waveform data that precedes a failure condition (pre-trigger data).Captured waveforms can be expanded to reveal minute details such as fast glitches,overshoot on pulses,and noise.These captured waveforms can
11、 be analyzed in either the time or frequency domains. Some oscilloscopes will: Monitor parameters such as amplitude fluctuations,timing jitter, risetime,etc.,and display worst-case values. Provide histograms of parameter measurements to accurately identify important signal characteristics. Let you u
12、se the full screen as a signal- viewing area. Allow signals to be saved or recalled from PC card devices such as portable hard drives,ATA Flash Cards, or IC memory cards. The Instrument Solution When you purchase an instrument,you need to understand basic digitizer speci- fications and architectures
13、 to make sure youve selected the right digitizer for the application.For analog oscilloscopes,the primary specifications are simply bandwidth,voltage sensitivity,and accuracy.For digital oscilloscopes,the basic specifications also include sample rate,waveform memory length,vertical resolution,and di
14、agnostic capabilities for troubleshooting.Some architectures are optimized for transient signal capture, while others only record repetitive signals.A general-purpose instrument can capture both single-shot and repet- itive waveforms. Know Your Waveform Before you evaluate digitizers,evaluate your s
15、ignals.Answering the following questions regarding your signal and the types of measurements needed will help you choose the right instrument.In the long run,this preparation will save time and money. 1. What is the signal bandwidth? 2. How small are the details you need to resolve relative to the p
16、eak-to- peak voltage? 3. How accurately do you want to measure voltages and times on the waveforms? 4. How long a waveform portion do you want to capture? 5. What conditions do you need to trigger on? 6. How often should the display update with new waveforms and analyzed results? 7. What kinds of di
17、agnostic tools do you want? 6 FUNDAMENTALS CONTENTS Fundamentals of Digital Oscilloscopes and Waveform Digitizing This technical note discusses how electronic signals are measured by data acquisition instruments and stored as numbers in fast memory. Concepts discussed include data sampling,triggerin
18、g, recording pre-trigger data, how sampling rate affects usable bandwidth,and how long memory improves sampling rate.There is also a brief discussion of diagnostic capabilities,including standard parameters, frequency analysis (FFT),and statistical analysis (histograms). 1 Digital Oscilloscopes 7 CO
19、NTENTS Transient Capture Most analog scopes have a difficult time displaying transient events.In contrast, many digital oscilloscopes are designed for transient capture.Three basic digitizer architectures exist.Transient digitizers and Random Interleaved Sampling (RIS) digitizers can capture transie
20、nt signals;sampling digitizers cannot.All three types can record repet- itive signals.Only transient and RIS digitizers record pre-trigger waveform information;sampling digitizers cannot. Transient digitizers contain an ADC and waveform memory.Once “armed” ,the ADC digitizes the signal continuously
21、and feeds the samples into memory using circular addressing.After the last memory location is filled,the system overwrites the stored data,starting at the beginning of memory.After a trigger is generated,memory continues to fill with a user-selected number of post-trigger samples.Then the ADC stops
22、feeding the memory.If the user had selected 100% pre-trigger data,the ADC would stop sending data as soon as the trigger arrived.If the user selected 100% post-trigger,the system would fill every memory location one more time and stop.Memory would contain the waveform data that occurred after the tr
23、igger. RIS digitizers consist of a transient digitizer with the addition of an interleaved mode.For each trigger,the RIS digitizer records a set of waveform sample points. The digitizer interleaves sample point sets from additional triggered acquisi- tions to construct a detailed representation of t
24、he original waveshape. Because the digitizer has no way to know when the trigger will arrive,the sample clock and trigger point are asynchronous.Therefore,the time between the trigger and the very next sample clock randomly varies from waveform acquisition to acquisition.The RIS architecture uses a
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- LeCroy_2001_Catalog 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf