1、Operators Manual Model 9210 300 MHz Programmable Pulse Generator March 1, 1995 Rev. B RadioFans.CN 收音机爱 好者资料库 LeCroy Innovators in Instrumentation Corporate Headquarters 700 Chestnut Ridge Road Chestnut Ridge, NY 10977-6499 Tel: (914) 578-6020, Fax: (914) 589-5985 European Headquarters 2, chemin-Pre
2、-de-la Fontaine 1217 Meyrin 1 Geneva, Switzerland Tel.: (022) 719 21 Copyright March 1, 1995, LeCroy. All fights reserved. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. RadioFans.CN 收音机爱 好者资料库 TABLE OF CONTENTS 3 9210 QUICK START .1
3、 Purpose .1 Quick Start Instructions .1 GEI-IING AROUND THE FRONT PANEL .5 Accessing the Control Displays .5 Selection of Parameters . 6 Adjusting Parameters with the Numeric Keypad .7 Adjusting Parameters with the Rotary Knob .7 Non-Numeric Entries . 8 Storing 115/220 VAC _.20%, 48 Hz to 448 Hz. Th
4、e 9210 will automatically adjust to the local line voltage. 3) Make certain that the Main Circuit Breaker/Line switch, on the rear panel, is in the ON position. 1 9210 Quick Start I/ SELECTDISPLAYGPIB POWER N-l/ HI DiS I t . J- .),nput output Pu.sE-,E,ro, 9210 J / Vlow Width I 2.00ns I Delay I 2.00n
5、s I Lead -Jl 1.00ns I Trail L I-. 1.00ns 12 Pulse I . OFF Main IPeriod 10.00ns I No,m, I sO I 4) Push the front panel POWER key. The 9210 will perform power-up calibration for approximately 30 seconds, then display the Channel A control menu screen. 5)Most of the pulse parameters and their controls
6、are accessed by touching the CRTkeys on the TouehCRT. Throughout this manual, the following symbols will be used to distinguish soft CRTkeys from actual front panel pushbuttons: WidthCRTkey Invert Front Panel Key 6) Touch Period. The key should highlight. 7)Release the CRTkey and turn the Outer Ring
7、 Knob (range). The Period changes in a 1-2-5 sequence. 9210 Quick Start 1 8) Turn the Center Knob (vernier). The Period will change smoothly. 9) Try varying the sensitivity of the vernier Knob using the keys. 10) Change the Period to 1.5 microseconds by pressing 11, .1, 51, u/MHzl. 11) Press Recall
8、Setup, and touch Standard and Execute to recall the factory default setup. The generator will now be in the NORMAL trigger mode, which is free running. 12) Connect the OUTPUTof the Module to a vertical input of an oscilloscope with a 50 cable, terminated at the scope end. 13) Press Disable on the Mo
9、dule to enable the Output. Adjust the scope to see the Pulse stream. Verify that the parameters on the generators CRT match those of the scope trace. 14) Touch Vhigh, and turn the vernier knob to vary the Pulse high level. 15) The pulse parameters are defined below. Vary each and observe its effect
10、on the scope trace. Note that the highlighted portion of the pulse icon on the displays upper right indicates graphically what has been selected for adjustment. Vhigh Vlow High level. This is the active level if Invert is not on. Low level. This is the quiescent level if Invert is not on. 19210 Quic
11、k Start Width Delay Lead Trail NOTE: 2 Pulse Period Pulse Width is measured from the start of the leading edge to the start of the trailing edge. Delay of the module Pulse output from the Trigger output, not including a fixed delay of typically 13 nsec. This also controls the time between the 2 puls
12、es in double pulse mode. Leading edge transition time, 10% to 9O%. Trailing edge transition time, 10% to 90%. Transition times (Lead and Trail) cannot be varied in the 9214 module. Turns double pulse mode ON or OFF. Defines the time between Output Pulses in NORMAL, GATE and BURST trigger modes. 2GET
13、TING AROUND THE FRONT PANEL Accessing the Control Displays DISPLAY Control Menus are brought to the 9210s display by pressing one of the five blue DISPLAY keys on the front panel. Press TRIGGER once to bring up the main Trigger control menu display. Press TRIGGER again and a second page of less freq
14、uently used trigger controls will be displayed. Repeated presses of the key will toggle the display between these two menus. The other four DISPLAY keys operate in a similar manner. See the table below for details. Keys Ion module) Display Channel Parameter Menu (2 pages) T.,Q. Trigger Parameter Men
15、u (2 pages) ,o., Utilities and Features Menu .E. On-Screen Operating Summary 2Getting Around the Front Panel Selection The selected parameter is the one that is highlighted (backlit). Parameters are selected by touching their corresponding CRTkey, or by pressing the SELECT 1, ,l, keys on the front p
16、anel until the desired parameter is highlighted. Note that when making selections with the CRTkeys, the selection process is not completed until the key is released. Channel A Page I Vhigh I VlowI WidthI Delay J Lead .:rol. Trail LI 2 Pulse Main J Period I JNormal ,1 SO I Boomv - OV 2.00ns 0.00ns 1.
17、00ns 1.00ns -OF F 10.00ns DIS I NOTE:If a 9214 module is installed in one of the module bays, the Lead and Trail CRTkey$ will not be displayed in that channels menu. 6 Getting Around the Front Panel 2 Adjusting Parameters with the Numeric Keypad A precise value for the selected parameter can be ente
18、red by pressing the numbers on the numeric keypad. Each number pressed will be displayed in the information window at the bottom of the CRT. The Back Space key is provided for deleting erroneous key presses. The +/- key will toggle the sign of the number being entered, and may be pressed at any time
19、 before terminating entry. After the sign and numeric portion of the desired value have been punched in, entry with the appropriate multiplier is terminated by pressing one of the four unit/entry keys (n/GHz, u/MHz, m/kHz, or Enter/Hz) at the right of the keypad. Adjusting Parameters with the Rotary
20、 Knob Continuous adjustment of the selected parameter can be accomplished using the concentric Rotary Knob. The Outer Ring Knob (range select) will set the parameters value in a 1-2-5 Sequence. As a convenience, if the Outer Knob is rotated by only one position and then turned back, the original val
21、ue will be restored, even if that value was not a 1, 2 or 5. The Center Knob (vernier) will change the value in a continuous, analog fashion. The sensitivity of the vernier Knob is controlled by using the Digit select keys located below the Knob. The Digit - key will move the selected digit to the r
22、ight, for finer adjustment, and the -Digit key will move the selected digit left, for more coarse adjustment. Note that the 4005 400 OFF Channel Menu showing Alternate Parameter Formats. NOTE: In a 3rd vertical format, the 2nd line is Median. Pressing CHANGE FORMAT with either Vhigh or Vlow selected
23、 will change the display for both parameters. The second vertical format controls the Output Pulse in the following manner: Ampl:This is the Pulse Amplitude, i.e., the difference between the quiescent and active levels of the Output Pulse. Base:This is the quiescent level of the Output Pulse. Note t
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- LeCroy_9210_Pulse_Generator_Operators_Manual 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-203304.html



Marshall-9100-62-02-Schematic电路原理图.pdf