philips PM3551A 电路图.pdf
《philips PM3551A 电路图.pdf》由会员分享,可在线阅读,更多相关《philips PM3551A 电路图.pdf(200页珍藏版)》请在收音机爱好者资料库上搜索。
1、Logic Analyzers PM 3551 A/10/30/50/70 Operating manual 9499 500 1 2911 831013 A PUBLICATION OF THE SCIENTIFIC AND INDUSTRIAL EQUIPMENT DIVISION PHILIPS EXPORT B.V. - EINDHOVEN - THE NETHERLANDS - 1983 PRINTED IN THE NETHERLANDS PHILIPS RadioFans.CN 收音机爱 好者资料库 1.2 TABLE OF CONTENTS Section 1 1.1 1.2
2、2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 3 3.1 3.2 3.2.1 3.2.2 4 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.2 5 5.1 5.1.1 5.1.2 5.2 5.3 5.3.1 5.4 6 6.1 6.2 7 8 8.1 , B.2 B.3 B.4 Description INTRODUCTION General information. Features CHARACTERISTICS. Logic State analyzer Logic Timing analyzer. Operation.
3、Display. Display modes. Compare mode Power supply Environmental characteristics. Physical characteristics Accessories and Options GENERAL DIRECTIONS Information and Warnings for the User. Description of controls, connectors and display. Front panel. Rear panel. DESCRIPTION OF THE MENUS Full menus Co
4、nfiguration menu Trigger menu Data menu. Compare menu Options menu Condensed menus. DESCRIPTION OF THE DATA DISPLAYS List Selective data Compare data Graph. Timing Timing compare Sync mode. CONNECTION Input. What else to connect? USER MESSAGE LIST. OPERATION. General. Triggering Selective data acqui
5、sition Compare. 1.4 1.4 1.5 2.1 2.4 2.9 2.11 2.11 2.12 2.13 2.13 2.14 2.16 2.17 3.1 3.2 3.6 3.6 3.9 4.1 4.3 4.3 4.7 4.17 4.21 4.27 4.32 5.1 5.3 5.7 5.8 5.9 5.12 5.15 5.16 6.1 6.2 6.3 7.1 8.1 8.2 8.2 8.4 8.4 -) PM 3551A Operating manual Chapt. 1 SW 2.0 JGB401 October 13, 1983 RadioFans.CN 收音机爱 好者资料库
6、1.3 TABLE OF CONTENTS (contd) Section 9 9.1 9.2 9.2.1 9.2.2 9.3 9.3.1 9.3.2 9.3.3 9.3.4 9.3.5 Description INTERFACE AND OPTIONS . Printer Interface. . Disassemblers General. Disassemblers Accesories . . Non-volatile memory. . . Disassembler connection and display. A Package. M Package. N Package. .
7、R Package. Z Package. . 9.1 9.2 9.4 . 9.5 9.7 9.10 9.11 9.18 . . 9.29 9.39 9.46 10 INSTALLATION INSTRUCTIONS FOR OPTIONS. . . . . 10.1 10.1 Unit identifier switch. . . . . 10.3 10.2 Additional 24-channel state analyzer 10.4 10.3 8-channel 50 MHz timing analyzer . . . . 10.5 10.4 Option board, disas
8、and non-volatile memory. . 10.10 11 IEEE-488 GPIB INTERFACE OPTION (PM 8851/40) . 11.1 12 RS 232-C CONTROL INTERFAC OPTION (PM 8851/20) . 12.1 13 PROBLEM REPORTS AND CHANGB REQUESTS . 13.1 PM 3551A Operating manual Chapt. 1 SW 2.0 JGB401 October 13, 1983 RadioFans.CN 收音机爱 好者资料库 1.6 1.2. FEATURES A f
9、unctionally organized keyboard/softkey structure in combination with an interactive menu-display serve the user in setting up and entering parameters for triggering, capturing, comparing and counting the activities of the system under test. The extensive triggering capability of the 7 sequential tri
10、gger-words, that can be combined with clock and trigger-qualifiers, permits capturing data from complex system activities or from deep branched or nested loops. Each trigger-word has the same width as the number of input channels of the various models. The sequence of the different trigger-words use
11、d can be defined by the use of an IF, THEN, ELSE algorithm, with the possiblity of placing a certain amount of delay between the statements. In this mode triggering can be selected as True or False. A notable feature of this mode is that the selected trigger sequence can be specified as true or alte
12、rnatively as not true. This latter mode is called Trigger on Sequence Break mode and provides the capability of triggering when a defined repetitive pattern (eg. a loop or a polling sequence) is broken or not executed in the specified order. The moment of capturing data can be delayed by states and/
13、or trigger occurrences and/or time. The Logic Analyzer can also be used for making time measurements. A readout of the elapsed time between two points in a programm can be obtained. Special features of note here are the COMBI and the SYNC modes. The COMBI mode allows the state section to be triggere
14、d by the timing section or vice-versa, while in the SYNC mode the displays of a number of timing channels are cross-referenced with state sampling. This enables analysis of critical state/time relationships. Data to be captured is clocked into the analyzer on selected clock edges of one of the three
15、 selectable clock sources. For each clock used, there are up to four qualifiers available. In the COMPARE mode, a comparison can be made between captured data and stored data in the formats: List or Timing. The instrument automatically stores the current mode-and function instrument-setting, when th
16、e mains voltage supply is switched off. After switching on) the instrument comes up in the initial default mode- and function setting. All analyzer models can be equipped with the option (non-volatile memory) to store up to 4 additional settings. Here each setting is stored and retrieved under a lab
17、el. PM 3551A Operating manual Chapt. 1 SW 2.0 JGB401 October 13, 1983 1.7 In the TIMING mode, glitches of a duration of as little as 5 nanoseconds can be captured from the data-stream. The PM 3551A can be equipped with a 4 channel 300MHz timing option, independently of the presence of the 8 channel
18、50 MHZ section. This allows high precision timing measurements. Other options are the options board with standard RS232C printer output. This board can be equiped with an GPIB control interface, or a RS232C control interface, both providing full remote control of the instrument. The options board is
19、 also a prerequisite for installation of disassembly- packages, and the non-volatile setting memory. The disassembly-packages allow the user to view captured data in the mnemonic language of the most currently available 8 and 16-bit microprocessors. Data is entered into the analyzer via 8-channe1 po
20、ds, each provided with its own threshold adjustment. A variety of convenient Pod-attachments are available for connecting the system under test to the analyzer. A comprehensive built-in diagnostic program can be used as an aid to test the various functions of the analyzer and to assist in fault-find
21、ing. PM 3551A Operating manual Chapt. 1 SW 2.0 JGB401 October 13, 1983 2.1 C H A R ACT E R 1ST I C S PM 3551A Operating manual Chapt. 2 SW 2.0 JGB402 October 12, 1983 2.2 2. CHARACTERISTICS The instrument has been designed and tested according to IEC Publication 348 for Class I instruments and has b
22、een suppll.ed in a safe condition. The present Operating Hanual contains information and warnings which should be followed by the purchaser to ensure safe operation and to maintain the instrument in a safe condition. Properties expressed in numerical values with stated tolerances are guaranteed for
23、ambient temperatures of +5 deg.C +40 deg.C unless stated otherwise. Numerical values without tolerances are typical and represent the characteristics of an average instrument. This specification is valid after the instrument has warmed up for 15 minutes. OPERATION MODES: TYPES: Type-numbers No of St
24、ate Channels -Logic State Analyzer only -Logic Timing Analyzer only -Comb:i Mode where the LSA can enable the triggering of the LTA or vice-versa. -SYNC Mode where timing analyzer data is cross-referenced with the state analyzer data. PM3551A/10 35 PM3551A/30 35 PH3551A/50 59 PH3551A/70 59 No of 50z
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- philips PM3551A 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


