Marconi_2023A_2024A_2025_Service_Manual 电路图.pdf
《Marconi_2023A_2024A_2025_Service_Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《Marconi_2023A_2024A_2025_Service_Manual 电路图.pdf(315页珍藏版)》请在收音机爱好者资料库上搜索。
1、 AM/FM SIGNAL GENERATORS 2023A, 2023B, 2025 Maintenance Manual Document part no. 46892/377 RadioFans.CN 收音机爱 好者资料库 AM/FM SIGNAL GENERATORS 2023, 2023A, 2023B, 2024 narrows the search down to a defined circuit area. Chapter 6 Replaceable parts Contains instrument and board component parts, and a sect
2、ion on miscellaneous mechanical parts. Chapter 7 Servicing diagrams Contains interconnection drawings, board circuits and component layout diagrams. Associated publications Refer to the relevant Operating Manual (part number 46882-225 for 2023 and 2024, part number 46882-373 for 2023A, 2023B and 202
3、5) for an up-to-date list of associated publications. RadioFans.CN 收音机爱 好者资料库 46882-377 iii Contents Precautions.iv Prcautions.vii Vorsichtsmanahmen. x Precauzioni .xiii Precauciones.xvi Chapter 1 TECHNICAL DESCRIPTION .1-1 Chapter 2 MAINTENANCE.2-1 Chapter 3 ADJUSTMENT PROCEDURES .3-1 Adjustments.3
4、-4 Recommended test equipment .3-7 Adjustment procedures.3-8 Adjustment procedures for instruments fitted with Option 3 or 11.3-22 Adjustment procedure tables.3-24 Appendix A Calibration GPIB commands .A-1 Chapter 4 INITIAL REPAIR.4-1 Chapter 5 FAULT DIAGNOSIS .5-1 Chapter 6 REPLACEABLE PARTS .6-1 C
5、hapter 7 SERVICING DIAGRAMS.7-1 Circuit notes.7-2 PRECAUTIONS iv 46882-377 Precautions These terms have specific meanings in this manual: WARNING Information to prevent personal injury. Information to prevent damage to the equipment. Important general information. Symbols used on this product The me
6、aning of hazard symbols appearing on the equipment is as follows: Symbol Nature of hazard General hazard Dangerous voltage Toxic hazard Static-sensitive components General conditions of use This product is designed and tested to comply with the requirements of IEC/EN61010-1 Safety requirements for e
7、lectrical equipment for measurement, control and laboratory use, for Class I portable equipment and is for use in a pollution degree 2 environment. The equipment is designed to operate from an installation category I and II supply. Equipment should be protected from the ingress of liquids and precip
8、itation such as rain, snow, etc. When moving the equipment from a cold to a hot environment, it is important to allow the temperature of the equipment to stabilize before it is connected to the supply to avoid condensation forming. The equipment must only be operated within the environmental conditi
9、ons specified in Chapter 1 Performance data in the Operating manual, otherwise the protection provided by the equipment may be impaired. This product is not approved for use in hazardous atmospheres or medical applications. If the equipment is to be used in a safety-related application, e.g. avionic
10、s or military applications, the suitability of the product must be assessed and approved for use by a competent person. WARNING Electrical hazards (AC supply voltage) This equipment conforms with IEC Safety Class I, meaning that it is provided with a protective grounding lead. To maintain this prote
11、ction the supply lead must always be connected to the source of supply via a socket with a grounded contact. Be aware that the supply filter contains capacitors that may remain charged after the equipment is disconnected from the supply. Although the stored energy is within the approved safety requi
12、rements, a slight shock may be felt if the plug pins are touched immediately after removal. PRECAUTIONS 46882-377 v Fuses Note that the internal supply fuse is in series with the live conductor of the supply lead. If connection is made to a 2-pin unpolarized supply socket, it is possible for the fus
13、e to become transposed to the neutral conductor, in which case, parts of the equipment could remain at supply potential even after the fuse has ruptured. Removal of covers Disconnect the supply before removing the covers so as to avoid the risk of exposing high voltage parts. If any internal adjustm
14、ent or servicing has to be carried out with the supply on, it must only be performed by a skilled person who is aware of the hazard involved. WARNING Electrical hazards (DC supply voltage) This equipment conforms with IEC safety Class III, meaning that for continued safety it must only be connected
15、to supplies and signal sources which conform to Separated Extra-Low Voltage (SELV and SELV-E) voltage and insulation requirements. No hazardous voltages are generated internally. See under Performance data in Chapter 1 of the Operating Manual for the maximum permitted voltage levels that can be appl
16、ied. WARNING Fire hazard Make sure that only fuses of the correct rating and type are used for replacement. If an integrally fused plug is used on the supply lead, ensure that the fuse rating is commensurate with the current requirements of this equipment. See under Performance data in Chapter 1 in
17、the Operating manual for power requirements. WARNING RF hazard Do not disconnect RF cables which are carrying high levels of RF power. High voltages, which can cause RF burns, may be present at the end of the unterminated cables due to standing waves. Switch off the transmitter or other source of RF
18、 power before disconnecting the cable from the equipment. WARNING Toxic hazards Some of the components used in this equipment may include resins and other materials which give off toxic fumes if incinerated. Take appropriate precautions, therefore, in the disposal of these items. WARNING Beryllia Be
19、ryllia (beryllium oxide) is used in the construction of the following components in this equipment : TR808 on AA1 and AA1/1; TR1 and TR2 on AA2/1 and AA2/7. PRECAUTIONS vi 46882/377 This material, when in the form of fine dust or vapor and inhaled into the lungs, can cause a respiratory disease. In
20、its solid form, as used here, it can be handled quite safely although it is prudent to avoid handling conditions which promote dust formation by surface abrasion. Because of this hazard, you are advised to be very careful in removing and disposing of these components. Do not put them in the general
21、industrial or domestic waste or despatch them by post. They should be separately and securely packed and clearly identified to show the nature of the hazard and then disposed of in a safe manner by an authorized toxic waste contractor. WARNING Beryllium copper Some mechanical components within this
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Marconi_2023A_2024A_2025_Service_Manual 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


