philips Pm5326电路图.pdf
《philips Pm5326电路图.pdf》由会员分享,可在线阅读,更多相关《philips Pm5326电路图.pdf(138页珍藏版)》请在收音机爱好者资料库上搜索。
1、RF signal generator lnst ruction manual 9499 520 08002 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 Qservice - This Document is a complete scan from the Original Tektronix Manual - Qservice RadioFans.CN 收音机爱 好者资料库 Please note In correspondence concerning this instrument, please quote the type num
2、ber and serial number a s given on the type plate. Bitte beachten Bei Schriftwechsel ijber dieses Gerat wird gebeten, die Typennummer und die Geratenummer anzugeben. Diese befinden sich auf dem Typenschild an der Ruckseite des Gerates. Noter s. v. p. Dans votre correspondance et dans vos reclamation
3、s s e rapportant B cet appareil, veuillez toujours indiquer le numero de type et le numero de serie qui sont marques sur la plaquette de caracteristiques. important As the instrument is an electrical apparatus, it may be operated only by trained personnel. Maintenance and repairs may also be carried
4、 out only by qualified personnel. Wichtig Da das Gerat ein elektrisches Betriebsmittel ist, darf die Bedienung nur durch eingewiesenes Personal erfolgen. Wartung und Reparatur durfen nur von geschultem, fach- und sachkundigem Personal durchgefuhrt werden. l mportant Comme Iinstrument est un equipeme
5、nt Blectrique, le service doit generator for 1 kHz sine, 3 - 30 Hz mains frequency with phase shifter Front view, mechanical parts Top view Bottom view Unit 1 Unit 4 Unit 6 Unit 3 Unit 2 Unit 5 Overall circuit diagram Circuit diagram: units 2, 3, 8, parts of unit 6 Circuit diagram: units 1,4, 5, par
6、ts of 6 Unit 8 ALLGEMEINES Einleitung Technische Daten Zubehor Funktionsprinzip VORBEREITUNGSANWEISUNGEN Sicherheitstechnische Hinweise Aufstellen Erden Offnen des Gehauses Netzanschluss BETRIEBSANLEITUNG Bedienungselemente und Anschlusse Bedienung und Anwendung Anwendungsbeispiele 1. Blockschaltbil
7、d, gesamt 2. Frontansicht 3. Amplitudenmodulation 4. Frequenzmodulation, Kalibrierung der Tragerfrequenz 5. Wobbeln, mit verschiebbarer Frequenzmarke, Einstellung der Mittenfrequenz (RF center) 6. Wobbeln, mit verschiebbarem Frequenzmarkenspektrum 7. Zahler fiir externe Frequenzen; Generator fur 1 k
8、Hz sinus, fur 3 - 30 Hz A , fur Netzfrequenz mit Phasenschieber TABLE DES MATIERES GENERALITES Introduction Caracteristiques techniques Accessoires Principe de fonctionnement INSTALLATION Consignes de securite Montage Mise B la terre Demontage de Iappareil Branchement de Iappareil MlSE EN SERVICE Co
9、mmandes et douilles Foqctionnement et application Exemples dapplication RAPPEL DES FIGURES Schema synoptique Face avant Modulation damplitude Modulation de frbquence, reglage de la frequence porteuse Wobbulation avec marque decalable de frequence, reglage de la frequence centrale (RF center) Wobbula
10、tion avec spectre decalable de reperes de frequence Compteur des frequences externes; genbrateur pour 1 kHz sinus, 3 - 30 Hz A , frequence secteur avec dephaseur Operating manual Qservice - This Document is a complete scan from the Original Tektronix Manual - Qservice TECHNICAL DATA General informat
11、ion: On delivery from the factory, the instrument complies with the safety regulations of measuring and control equipment. The information and warnings contained in this instruction manual must be followed by the user to ensure safe operation and to maintain the instrument in a safe condition. - Onl
12、y data with indicated tolerances or limits are guaranteed; data without tolerances are given only for guidance. - All specifications will be met after a warm-up time of 30 min. when keeping the instrument in a constant mounting position. - Inaccuracies (absolute or in %) relate to the indicated refe
13、rence value. SPECIFICATIONS R F Generator Frequency range Ranges Frequency display Error of the display Temperature coefficient of the display Temperature coeffiecient of the frequency 1.2.2. R F Sweep generator Ranges wave form 1.2.3. RF output Attenuator 0,l - 125 MHz 0.1 - O,25 MHz 0,25 - 0,5 MHz
14、 0,5 - 1 MHz 1 - 2,5 MHz 2,5 - 5 MHz 5 - 10 MHz 10 - 25 MHz 25 - 50 MHz 50 - 125 MHz 5-digit LED display, red, 11 mm high; 3 decimal points; 2 LEDs for dimension kHz, MHz typical, +I digit +5 x 1 O-/OC at 23 OC f 20 OC - 1 0-51c .4/.5 MHz 1011 1 MHz 36/41 MHz 7511 10 MHz semi-rectangular for all RF
15、ranges and all sweep ranges Connection: BNC connector RF OUT Impedance: 75 G? max. output voltage: 50 mV into 75 G? Frequency response: 100 dB total 0 - 80 dB continous 3 dB, 40 dB calibrated 1.2.4. Modulation Modulation modes unmodulated amplitude-modulated, AM frequency-modulated, FM Frequency res
16、ponse Modulating output MOD OUT Amplitude modulation u nmodulated AM, internal AM, external Frequency modulation FM, internal FM, external 1.2.5. Wobbulation Ranges, wobbulation width Frequency response Wobble frequency, triangle - Linearity error Wobble frequency, sine-wave Center frequency Wobbula
17、ting output SWEEP OUT - Signal - Frequency - Amplitude - Impedance see also table in chapter 3.2. all RF ranges and all sweep ranges all RF ranges and all sweep ranges sweep ranges 1011 1 and 7511 10 MHz 2 dB in .4/.5 and I011 I MHz ranges 1 0 k R 1011 1 and 75 /I 10 MHz ranges Modulation frequency:
18、 1 kHz sine Sweep (A f) : 22,5 kHz Modulation signal: 20 Hz - 60 kHz (3 dB) Sweep ( A f) : 0 - 75 kHz Modulation coefficient: 200 mV/ for this purpose press the buttons A of the handle (Fig. 2). Do not position the instrument on any surface which produces or radiates heat, or in direct sunlight. EAR
19、THING Before switching on, the instrument must be earthed in conformity with the local safety regulations. The mains cable fixed to the instrument includes a protective conductor, which is connected to the earth contacts of the plug. Thus, when connected to an earthed mains socket, the cabinet of th
20、e instru- ment is consequently connected to the protective earth. WARNING: Connect the mains cable plug only to a socket with protective earth contacts. This pro- tection must not be made ineffective, e. g. by using an extension cable without earth protection! The circuit earth potential applied to
21、the external contacts of BNC sockets is connected to the cabinet. The external contacts of the BNC sockets must not be used to conpect a protective conductor. DISMANTLING THE INSTRUMENT - Unplug the mains connector - Fold up the handle to the top. For this push the buttons A (Fig. 2) - Loosen the ce
22、ntral screw at the rear - Remove the lead-through of the mains cable from the cabinet - Dismantle the cabinet MAINS CONNECTION The instrument must be connected only to an AC supply. On delivery the instrument is set to 230 V. Before mains connection, ensure that the local mains voltage ranges within
23、 the set mains voltage range indicated on the plate at the rear of the instrument. If the instrument is to be used on 11 5 V supply, proceed as follows: - Unplug the mains connector - Dismantle the instrument, see 2.4. - Resolder links on the mains transformer in accordance with the stick-on connect
24、ion diagram. See also below. - Insert the supplied fuse 250 mA delayed into the fuse holder instead of the one built-in - Change the mains voltage plate at the rear of the instrument in accordance with the mains voltage selected. This plate for 11 5 V is inserted into a plastic cover - Close the ins