Rohde_Schwarz_UAF_22 电路图.pdf
《Rohde_Schwarz_UAF_22 电路图.pdf》由会员分享,可在线阅读,更多相关《Rohde_Schwarz_UAF_22 电路图.pdf(8页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Ease of operation 3 signal inputs 25 video parameters Limit monitoring Full-field measurements Convenient result display Freely selectable test signal Memory card Printer interface Remote control (IEC/IEEE bus) Small dimensions Video Analyzer UAF Perfection in video analysis UAF_22.fm Seite 1 Diens
2、tag, 10. Oktober 2000 2:20 14 RadioFans.CN 收音机爱 好者资料库 2 Video Analyzer UAF Brief description Rapid Precise Reliable Measurement accuracy for satisfying stu- dio quality requirements and measuring times in the seconds range these are the standards which have to be met in present-day automatic video m
3、easure- ment engineering. Thanks to its outstand- ing characteristics, Video Analyzer UAF from Rohde storage of up to eight test configurations is possible. Thanks to its variable integration time, the UAF can be adapted to all test condi- tions. Using the shortest integration time of less than 1 s,
4、 the UAF is ideal for all alignments, be it in the studio or in pro- duction. In the case of very noisy VTR sig- nals, on long transmission links or at the end of a long line of transposers, increas- ing the integration time to 2.5, 5 or 10 s always yields stable results. For measurements in the fie
5、ld, on cable net- works or at inaccessible points in transmitters, it is not necessary to bring along a com- puter or printer to log data. Using a plug-in memory card, customer- defined test and data-logging programs can be loaded and the test results also stored on the card. Moreover, the memory ca
6、rd permits stor- age of complete instrument setups: limit values, test parameter definitions, filter settings in the case of noise voltage mea- surements as well as line numbers of the eight test configurations. Thus any mea- surement can be reproduced. For use in quality and production control of v
7、ideo recorders, the UAF also handles the S-VHS component signals Y/C. Distorted test signals due to jitter or head switchover for instance do not affect the operation of the UAF. A selection of the manifold applications of the UAF UAF_22.fm Seite 2 Dienstag, 10. Oktober 2000 2:20 14 RadioFans.CN 收音机
8、爱 好者资料库 Video Analyzer UAF 3 Mode 1Mode 4Mode 2Mode 3Mode 5 Mode 6Mode 7Mode 8 Operation The logical arrangement of the UAF front- panel controls offers a clear overview of its functions and ensures ease of opera- tion. Each parameter is assigned its own key. The associated LED above the key blinks
9、if the limit values are exceeded. Thus all parameters can be checked at a glance for adherence to set limits. The illuminated LC display shows the result in large figures which are easy to read even from some distance. Several parameters can be displayed at the same time in small characters. For cer
10、tain appli- cations, eg alignment, the bar indication proves useful. The complete device setup and the selected limit values are contained in the upper lines of the display. The lower part shows the function of the unlabelled keys. These softkeys offer user prompting with respect to the displayed me
11、asured value or the called function. The small keypad to the left of the display permits the setup menus of the UAF to be selected directly. Such a menu is inserted as a window above the normal result dis- play. So it is possible to use the softkeys for changing general settings such as selected inp
12、ut, synchronization or printer mode. Further test parameters, eg an external level or future extensions, can be called up using the “option” function. For integration into computer-controlled test systems, all functions of the UAF can be remote-controlled via an IEC/IEEE-bus interface. The UAF can a
13、lso be used as the controller. If parameter logging is required for acceptance test measure- ments, a printer can be connected directly to the Centronics interface. Test signal eg CCIR 17, 10T pulse/20T pulse Test line eg CCIR 17 in line 19 Limit values eg BARSet 1: +10% / 15% Set 2: +15% / 20% Hyst
14、eresis: 3% For rapid recall, for instance within a test routine, the UAF is able to store up to 8 test configurations (modes 1 to 8) Parameter definitions eg S/N, weighting filter on/off The test results are displayed either in the form of numerical values or as bars UAF_22.fm Seite 3 Dienstag, 10.
15、Oktober 2000 2:20 14 RadioFans.CN 收音机爱 好者资料库 4 Video Analyzer UAF Special modes Difference measurement This mode permits signal errors at the input of the device under test (DUT) to be eliminated. For this purpose the input sig- nal of the DUT is applied to channel A and the output signal to channel
16、 B of the UAF. In this way it is possible to perform mea- surements on a transposer system or a cable headend receiving incorrect input signals. Thanks to the high display accuracy of the UAF, the difference measurement mode is also suitable for high-precision studio measurements on components such
17、as routing switchers which feature stringent tolerances. Reference measurement In this mode only one input of the UAF is connected to the DUT, the first test cycle being stored as the reference. This mode facilitates determination of the effect of the environment (EMC, climate, etc) on video generat
18、ors in the lab and in servic- ing. Automatic test sequence The AUTORUN menu allows test sequences to be programmed on the UAF front panel; these sequences are exe- cuted automatically and can be repeated cyclically using the built-in realtime clock. An AUTORUN routine may for instance ensure input s
19、witchover, mode variation, limit monitoring and result logging. Since the UAF is able to act as a controller for other instruments, its controller func- tions can be included in an AUTORUN routine. Thus it is for instance possible to send commands to the IEC/IEEE-bus- compatible TV Test Receiver EMF
20、T (data sheet PD 756.4843) in order to set the receive channel. Without the use of a controller, the UAF and EMFT are able to set all channels of a cable network, mon- itor the signal quality and print error logs in the AUTORUN mode. This capability can even be extended when using the Video Selector
21、 VSF. Description and technology The combination of analog signal condi- tioning and digital result processing is the basis of the powerful performance of the UAF and all this in spite of its small size. In the analog section, the video signal is processed in parallel by different preci- sion test c
22、ircuits for chrominance and luminance measurements. An A/D con- verter digitizes both the test circuit output voltages and parts of the video signal directly. Its 12-bit resolution together with the precise analog circuitry ensure the unique measurement accuracy of the UAF. The core of the digital s