HP-205A-Manual-SNP-953 电路图.pdf
《HP-205A-Manual-SNP-953 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-205A-Manual-SNP-953 电路图.pdf(42页珍藏版)》请在收音机爱好者资料库上搜索。
1、 HP Archive This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! Thanks to on-line curator: Joe Geller RadioFans.CN 收音机爱 好者资料库 OPERAtiNG AND 5tHVIl;t MANUAL H P PART NO. 00205-90010 AUDIO SIGNAL GENERATOR MODELS 205A AND 205AG COVERS ALL SERIALS HE
2、WLETTlliPACKARD RadioFans.CN 收音机爱 好者资料库 OPERATING AND SERVICE MANUAl HP PART NO. 00205- 90010 AUDIO SIGNAL GENERATOR MODELS 205A AND 205AG COVERS ALL SERIALS Manual for Serials Prefixed: 953 Manual Changes for Serials 0953A 11577 and above Manual Backdating Changes (Appendix C) for Serials Prefixed:
3、 953, 246-, 231,151,024-,012 and Serials 8462 and below (205A) Copyright Hewlett-Packard Company 1955 P.O. Box 301, Loveland, Colorado, 80537 U.S.A. Printed: DEC 1970 RadioFans.CN 收音机爱 好者资料库 Table of Contents Model205AG TABLE OF CONTENTS Section Page Section Page GENERAL INFORMATION 1-1 5-14. Dial A
4、ccuracy 5-1 I-I. Description 1-1 5-18. Output Flatness 5-2 1-3. Instrument Specifications and 5-26. Distortion 5-2 General Information I-I 5-30. Hum Level , 5-2 1-5. Instrument and Manual Identification 1-1 5-39. Output Attenuator Accuracy Check 5-2 Section Page 5-56. Input Meter Check 54 II INSTALL
5、ATION 2-1 5-63. Input Attenuator Accuracy 54 2-1. Introduction 2-1 5-73. Adjustment Procedure 5-5 2-3. Inspection 2-1 5-74. Frequency Calibration Adjustment 5-5 2-5. Power Requirements 2-1 5-82. Output Level Meter Adjustment : 5-5 2-7. Grounding Requirements 2-1 5-85. Input Level Meter Adjustment 5-
6、8 2-10. Rack/Bench Installation 2-1 5-90. Troubleshooting 5-8 2-12. Repackaging for Shipment 2-1 5-91 . Distortion 5-8 5-93. Intermittent Output 5-8 Section Page 5-96. Repair Procedures 5-8 III OPERATING INSTRUCTIONS 3-1 5-97. Cabinet Removal 5-8 3-1. Introduction 3-1 5-99. Tube Replacement 5-9 3-3.
7、 Panel Features 3-1 5-101. Capacitor Drive Lubrication 5-9 3-5. Preliminary Checks 3-1 5-103. Replacement of Lamp Rll 5-9 3-7. Operating Instructions 3-1 3-8. Oscillator Operation 3-1 Section Page 3-10. Output Level Meter Operation 3-1 VI REPLACEABLE PARTS 6-1 3-15. Input Level Meter Operation 34 6-
8、1. Introduction 6-1 64. Ordering Information 6-1 Section Page 6-6. Non-Listed Parts 6-1 IV THEORY OF OPERATION 4-1 4-1. General 4-1 Section Page VII CIRCUIT DIAGRAMS 7-1 Section Page 7-1. Introduction 7-1 V MAINTENANCE 5-1 5-1. Introduction 5-1 APPENDICES 5-3. Required Test Equipment 5-1 A. CODE LIS
9、T OF MANUFACTURERS 5-5. Performance Checks 5-1 B. SALES AND SERVICE OFFICES 5-7. Frequency Range 5-1 C. MANUAL BACKDATING CHANGES LIST OF TABLES Nm Pa Number Page I-I. Specifications 1.Q 5-1. Required Test Equipment 5.Q 1-2. General Information : 1.Q 5-2. Dial Accuracy Check 5-1 3-1. Output Meter Vo
10、ltage 5-3. Factory Selected Components 5-8 Multiplying Factor 3-1 54. Troubleshooting Chart 5-9/5-10 3-2. Input Meter Voltage Multiplying Factor 34 6-1. Replaceable Parts 6-2 III Model205AG Table of Contents ) Number I-I. Model 205 AG Audio Signal Generator 3-1. Model 205AG Panel Features 3-2. Outpu
11、t Voltage Correction Factors When Using Output Attenuators 3-3. Input Level Meter Correction Curve 4-1. Block Diagram Model 205AG LIST 0 FILL USTRATI 0NS Page Number Page 5-1. Logarithmic Addition of I-I Hum Harmonics 5-3 3-2 5-2. I dB Attenuator Accuracy Check 54 5-3. Adjustments and Chassis Compon
12、ent 3-3 Location (Top View) 54. Adjustments and Chassis Component 5-6 Location (Bottom View) 5-7 34 7-1. Model 205AG Audio Signai Generator Circuit 4-1 and AllA2 Component Locator 7-3 iv Section I Model205AG Table 1-1. Specifications Frequency R3nge: 20 Hz 10 20 kHz in three decade bands: Xl 20 Hz t
13、o 200 Hz XIO 200 Hz to 2 kHz XI00 2 kHz to 20 kHz Calibration covers approximately 270 degrees on 6 inch diameter main dial. Dial Accuracy: WitlUn 2k of setting at normal ambient tempera tures. (Includes warm-up and changes due to aging of tubes and components.) Output Flatness: 1.5 dB 20 Hz to 20 k
14、Hz at output levels; 30 dBm with output meter reading held at +37 dB (refer ence =1000 Hz) 1 dB 20 Hz to 20,kHz at output levels 1,11 10 INPUT ATIENUATOR (DB) This switch is the range switch for the INPUT LEVEL meter and is calibrated in steps of 5 dB from 0 to 40 dB. POWER ON This switch controls t
15、he power supplied to the instrument from the power line. FREQUENCY RANGE The position of this switch indicates the multiply ing factor to be used with the frequency dial indication. CD FREQUENCY VERNIER Permits fme tuning of the FREQUENCY dial. AMPLITUDE The control adjusts the amplitude of oscillat
16、or voltage applied to the output amplifier. The calibration is in arbitrary units. LOAD ON This switch is used to connect an internal 600 ohm load across the OUTPUT terminals. IMPEDANCE This switch selects the instrument output imped ance. The available impedances are 50, 200, 600, and 5000 ohms. CD
17、 OUTPUT The instrument output appears at four terminals. The terminal marked CT is the center tap of the line matching transformer. The -4-terminal is connected to the chassis. The two vertically spaced terminals are connected to the line matching transformer through the IMPEDANCE switch. A balanced
18、 output is obtained from the vertically spaced terminals and an unbalanced output may be obtained by connecting the terminal to one of the output terminals with the captive link provided. I dB ATTENUATOR Attenuates output in 10 steps of 1 dB each. 10 dB ATIENUATOR Attenuates output in 10 steps of 10
19、 dB each. . FREQUENCY Dial This dial is calibrated in Hz. The output frequency is the frequency dial indication multiplied by the FREQUENCY RANGE switch position. Figure 3-1. Model 205AG Panel Features 3-2 Model205AG Section III POWER Indicator Light Illuminates when line switch is ON, indicating pr
20、imary power has been applied to the instrument. OUTPUT LEVEL This meter indicates the voltage at the output terminals when the IMPEDANCE switch is set at 600, output attenuators both at zero, and the instrument is loaded with the internal or an external 600 ohm load. Under other operating conditions
21、 the meter may be used as a monitor to insure constant output voltage. INPUT LEVEL This meter measures the voHage applied to the input terminals and the range of the meter is controlled by the INPUT ATTENUATOR (DB) range switch. INPUT These terminals are the input for the audio frequency INPUT LEVEL
22、 vacuum tube voltmeter in the instrument. FUSE The fuseholder, located on the back of the chassis, contains the power line fuse. Refer to the Table of Replaceable Parts (6-1) for the correct fuse rating. PRIMARY POWER RECEPTACLE Connects primary power to the instrument. 115 V1230 V Slide SWitch S6 s
23、elects nominal operating voltage of the instru ment. PIO Figure 3-1. 0 10 20 30 CD a I 40 z 0 t50 z I.lJ 60 t- t a. t 80 : 0 90 100 110 I I I I !I , - , , .000001 .00001 .0001 .001 .01 .1 OUTPUT M ETER VOLTAGE MULTI PLYI NG FACTOR FOR 600 OHM LOAD Figure 3-2. Output Voltage Correction Factors When U
24、sing Output Attenuators Model 20SAG Panel Features 20AG-8-Z3IJ 3-3 Section III 3-15. INPUT LEVEL METER OPERATION. 3-16. The Input Level meter is an independent audio frequency vacuum tube voltmeter, suitable for monitoring the output voltage of a device under test. The meter is calibrated in volts a
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-205A-Manual-SNP-953 电路图 HP 205 Manual SNP 953
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


