HP-400AB-Manual-sn-482 电路图.pdf
《HP-400AB-Manual-sn-482 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-400AB-Manual-sn-482 电路图.pdf(44页珍藏版)》请在收音机爱好者资料库上搜索。
1、 HP Archive This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! On-line curator: Glenn Robb This document is for FREE distribution only! RadioFans.CN 收音机爱 好者资料库 INSTRUCTIONMANUALCHANGES MODEL400AB VAC,DUMTUBEVOLTMETER C12:changeto-hp-StockNo.18-31
2、;Mfr.,X C26:changeto-hp-StockNo.18-40HP;Mfr.,CC C29:changetocapacitor,fixed,electrolytic,2sections, 1500uf/sect.,15vdcw;-hp-StockNo.18-48HP;Mfr.,CC V1,changetotube,electron,selected,6CB6; V2:-hp-StockNo.G-73W;Mfr.,E V7:changetotube,electron,6CB6; -hp-StockNo.212-6CB6;Mfr.,ZZ Serial1182andabove: NOTE
3、:The1000:1inputvoltagedividerhasbeenchangedfrom acapacitivetoaresistivetype.Referencestoa capacitivevoltagedividershouldbechangedaccordingly: pg.3-1fig.3;pg.3-2para.3-2. Page4-9fig.6:call-outtoC3shouldread:Adjust highfrequencyresponseon3-voltrange. Thetextatthetophalfofpage4-4shouldbechanged toreada
4、sfollows: page4-4 Calibrationconsistsoftwoparts:(1)Adjustingthe amlifiergainonthe1voltrangewithR43(seefig.5). (2)Checkingthefrequencyresponseadjustmentofthe 1000:1divideronthe3voltrange.Thecompensation adjustmentismadewithC3.DONOTDISTURBTHIS ADJUSTMENTUNLESSA HIGHFREQUENCYSTANDARDISAVAILABLE. THISAD
5、JUSTMENTDRASTICALLY AFFECTSTHEFREQUENCY RESPONSEOFTHEINSTRUMENTONTHE3VOLTANDABOVERANGES. HEWLETT-PACKARDco. RadioFans.CN 收音机爱 好者资料库 Model400ABpage-2- Procedureg a.Allowtheinstrumenttoheatfor5minutesbefore calibrating. b.Connectalowdistortiontestoscillatorandanac voltmeteraccuratewithin1/2%at400cpsto
6、the INPUTterminalsoftheModel400AB c.SettheModel400ABrangeswithtothe1voltposition andapplyexactly1voltat400cpstotheINPUT terminals. d.AdjustR43sothattheinstrumentreads1.00volt. Thiscompletesthebasiccalibrationoftheinstrument. Thefollowingstepsshouldbefollowedifsuitableequip- mentisavailablefordetermi
7、nlngfrequencyresponse.An -hp-Model410B,400Dvoltmeterareexcellentforthis purpose. e.SettheModel400ABonthe3voltrangeandapply 3voltsat400cps.Notethereadingonthemonitor meter. f.Changethefrequencyto500kcandadjustthelevel untilthemonitormeterreadsthesameasat400cps. AdjustC3tomaketheModel400ABreadthesamea
8、s at400cps. g.Checktheresponseovertherangeof100kcto600kc. ItmaybedesirabletoadjustC3slightlytosplit anyerrortoobtainthebestover-allaccuracy. Section4-10shouldreadg; Thehighfrequencyresponseoftheamplifierisaffected bythevalueofC25,whichneverneedsadjustment.The lowfrequencyresponseatOcpsisaffectedbyth
9、e valueofR56.Smallervaluesofresistancelower tperesponseat10cps.ThevalueofR56isselected atthefactoyandshouldneverneedadjustment. Poorfrequencyresponseat10cpsisusuallydueto weaktubes.V2andV3havethemostaffect.The amplifierhasapproximately45dbofnegativefeedback whichmakesthefrequencyresponsealmostindepe
10、ndent oftubeagingatmid-frequencies.Weaktubeswill affectthefrequencyresponsesomewhatat600kcand 10cps,wherethefeedbackisless. The1000:1resistiveinputdlviderisadjustedforflat frequencyresponsewlthC3onthe3-voltrange.NO ATTEMPTTOADJUST C3SHOULDBEMADEUNLESS A REFERENCE VOLTMETERISAVAILABLEWHICHHASFLATFREQ
11、UENCY RESPONSEFROM400cpsTO600KC. .- RadioFans.CN 收音机爱 好者资料库 Model400ABpage-3- TheTableofReplaceablePartsshouldbechangedasfollows R3,R4:changetoresistor,matched,R3=10031megohms, R4=10.21K;-hp-StockNo.400D-67;Mfr.,HP R5:deletethiscircuitreference ADDR65:,resistorfixed,composition,100ohms,+10%,1/2W; -h
12、p-StocNo.23-100;Mfr.,B ADDR66:resistor,2.2megohms,10%,Electricalvalueadjusted atfactory;averagevalueshown. Theschematicdiagramshouldbechangedasshowninthefollowing sketch. . MODEL400AB PRODUCATIONCHANGE Serial1182andAbove Inputvoltagedividerchangedfromcapacitivetoresistivetype. adjutfrequ.encyrespons
13、e on 3voltrangeat500 kc Cl.01Jlf C30 110JlJlR6470 2 R33 R710K 10.3lM 4 5 6 7 R4 8 SlaIC51,0 C4 10.2lK 9 Rl .017. R66* 330K2.2M R65 100 - C2 + R2 20Jlf lOOK - *Valueadjustedatfactory. ,. OPERATINGANDSERVICINGMANUAL FOR MODEL400AB VACUUMTUBEVOLTMETER Serial982andAbove Copyright1957byHewlett-PackardCom
14、pany Theinformationcontainedinthisbooklet isintendedfortheoperationandmain- tenanceoCHewlett-Packardequipmentand isnottobeusedotherwiseorreproduced withoutthewrittenconsentoftheHewlett- PackardCompany. HEWLETT-PACKARDCOMPANY 275PAGEMILLROAD,PALOALTO,CALIFORNIA,U.S.A. 400AB004-3 TABLE1.SPECIFICATIONS
15、FORMODEL400AB VOLTAGERANGE:0.3mvto300volts.11ranges,selected withfrontpanelswitch.Fullscaleread- ingsof: FREQUENCYRANGE: 0.003volts 0.01 0.3 10cpsto600KC. O. 1 0.3 l.0 3.0 10.0 30 100 300 ACCURACY: CALIBRATION: INPUTIMPEDANCE: AMPLIFIER: POWER: SIZE: WEIGHT: Withnominallinevoltage10%(103volts to127v
16、olts),overallaccuracyiswithin 2%offullscale,20cpsto100KC,3% 10cpsto600KC. Readsrmsvalueofsinewave.Voltage indicationproportionaltoaveragevalue ofappliedwave.Linearvoltagescales, oto3and0toL0;dbscale,-12dbto +2db,basedon0dbm=1mwin600ohms, 10dbintervalsbetweenranges. 10megohmsshuntedbylessthan25l-L. O
17、utputterminalsareprovidedsovolt- metercanbeusedtoamplifysmallsig- nalsormonitorwaveformsundertest withanoscilloscope.Atleast0.25volts availablefrom600ohmsource.Ampli- fierresponsesameasvoltmeterabove 20cps. 115/230volts,10%,50/1000cps,approx. 75watts. CabinetMount:11-1/2high,7-1/2 wide,8-1/4deep. Ra
18、ckMount:19wide,7high, 8-1/4deep. CabinetMount:Net13Ibs.;shipping weight19lbs. RackMount:Net16lbs.;shipping weight26lbs. TABLEOFCONTENTS MODEL400AB VACUUMTUBEVOLTMETER PageNo. SectionIGENERAL 1-1GeneralDescription.I-I 1-2DamageinTransit1-1 1-3PowerTransformerConversionI-I 1-4AccessoriesAvailable.1-2
19、SectionIIOPERATINGINSTRUCTIONS 2-I 2-2 2-3 2-4 2-5 2-6 ControlsandTerminals Operation,General. VoltageMeasurement DBMeasurement Usingthe400ABasanAmplifier. AverageRespondingMeters 2-1 2-2 2-2 2-4 2-5 2-5 SectionIIITHEORYOFOPERATION 3-1 3-2 3-3 3-4 3-5 General InputVoltageDivider VoltmeterAmplifier.
20、MeterandRectifier. PowerSupply. . . . . . 3-1 3-2 3-2 3-2 3-2 SectionIVMAINTENANCE 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 4-9 4-10 Introductory CaseRemoval ServicingEqipmentRequired. TroubleLocalization. PowerSupply. VoltmeterCalibrationandGain TubeReplacement MeterZeroAdjustment ResidualMeterReading Frequ
21、encyResponse. 4-1 4-1 4-1 4-2 4-3 4-3 4-4 4-5 4-5 4-6 SectionVTABLEOFREPLACEABLEPARTS5-1 SECTIONI GENERAL 1-1GENERALDESCRIPTION TheModel400ABisacompactvacuumtubevoltmeterwhichwill measurevoltagesfrom.003voltsfullscaleto300voltsfullscale overafrequencyrangefrom10cpsto600KC.Theinputimped- anceis10mego
22、hmsshuntedbylessthan25-L-Lf. Thebasicaccuracyofthesemeasurementsis2%offullscalein- dicationonallrangesfrom20cpsto100KCwitha3%accuracy offullscaleindicationsonallrangesovertheentirerangefrom lOcpsto600KC.IthasareadablesensitivitytoO.3millivolts whichissufficienttomeasurehumlevelandnoisedirectly,as we
23、llasperformingavarietyoflaboratoryfunctionsinmeasuring gain,networkresponse,andoutputlevel. Theinstrumentisprovidedwithoutputterminalssothatitmaybe usedasahighgain(40db)broadbandamplifiertoincreasethe sensitivityofexternalequipmentsuchasoscilloscopesorpridges. 1-2DAMAGEINTRANSIT Shouldshippingdamage
24、becomeevidentuponunpackingthisinstru- ment,followtheprocedureoutlinedintheClaimforDamage sectiononthelastpageofthismanual. 1-3POWERTRANSFORMERCONVERSION ShoulditbedesiredtoconverttheModel400ABtooperatefrom a230vsupplyproceedasfollows: a.Removethetwobarewirejumpersontheterminal striplocatedontheright
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-400AB-Manual-sn-482 电路图 HP 400 AB Manual sn 482
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf