HP-1707B-Manual 电路图.pdf
《HP-1707B-Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-1707B-Manual 电路图.pdf(217页珍藏版)》请在收音机爱好者资料库上搜索。
1、I . : HP Archive . . This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! . . On-line curator: Tony Gerbic RadioFans.CN 收音机爱 好者资料库 m r - 0 b F P O P E R A T I N G A N D S E R V I C E M A N U A L OSCILLOSCOPE 1707B - - _ - - HEWLETT PACKARD RadioFan
2、s.CN 收音机爱 好者资料库 . OPERATING AND SERVICE MANUAL MODEL 1707B OSCILLOSCOPE 4 SERIALS PREFIXED: 1410A Refer to Section VI1 for instruments with the following standard options: 002,007,011,012,015,602,607,611 and 631. H EWLETT-PAC KA R D COMPANY/COLO RA DO SPRINGS DIV IS1 O N 1900 GARDEN OF THE GODS ROAD
3、, COLORADO SPRINGS, COLORADO, U.S.A. Manual Part Number 01707-90916 Microfiche Number 01 707-908 16 PRINTED: APRIL 1974 RadioFans.CN 收音机爱 好者资料库 SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to
4、comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Hewlett- Packard Company assumes no liability for the customers failure to comply with these requirements. GROUND THE INSTRUMENT. To
5、minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. The instrument is equipped with a three-conductor ac power cable. The power cable must either be plugged into an approved three-contact electrical outlet or used with a three- contact to two-contact
6、adapter with the grounding wire (green) firmly connected to an elmtrical ground (safety ground) at the power outlet. The power jack and mating plug of the-power cable meet International Electrotechnical Commission (IEC) safety standards. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Do not operate the
7、instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard. KEEP AWAY FROM LIVE CIRCUITS. Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made
8、 by qualified maintenance personnel. Do not replace components with power ca ble connected. Under certain conditions, dangerous voltages may exist even with the power cable removed. To avoid injuries, always disconnect power and discharge circuits before touching them. DO NOT SERVICE OR ADJUST ALONE
9、. Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present. USE CAUTION WHEN EXPOSING OR HANDLING THE CRT. Breakage of the cathode-ray tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To prevent CRT
10、implosion, avoid rough handling or jarring of the instrument. Handling of the CRT shall be done only by qualified maintenance personnel using approved safety mask and gloves. DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT. Because of the danger of introducing additional hazards, do not install substit
11、ute parts or perform any un- authorized modification to the instrument. Return the instrument to a Hewlett-Packard Sales and Service Office for service and repair to ensure that safety features are maintained. DANGEROUS PROCEDURE WARNINGS. Warnings, such as the example below, precede potentially dan
12、gerous procedures throughout this manual. Instructions contained in the warnings must be followed. Dangerous voltages, capable of causing death, are present in this instrumezt. Use extreme caution when handling, testing, and adjusting. I Model 1707H TABLE OF CONTENTS J I I Section Page I GENERAL INF
13、ORMATION . 1-1 1.1 . 1.4 . 1.5 . 1.7 . 1-1 1 . 1.17 . 1.20 . 1.22 . 1.24 . 1.26 . 1.30 . Introduction . 1-1 Description . 1 . 1 Introduction . 1-1 Vertical Circuits . 1-1 Horizontal Circuits . 1-1 Cathode-ray Tube . 1-5 Warranty . 1-5 Accessories Furnished . 1-5 Accessories Available . 1-5 Instrumen
14、t and Manual Identification . 1-5 Inquiries . 1-5 I1 INSTALLATION . 2-1 2.1 . 2.3 . 2.6 . 2.7 . 2-1 1 . 2.13 . 2- 15 . 2.17 . 2.19 . Introduction . 2-1 Initial Inspection . 2-1 Preparation for Use . 2-1 Power Requirements . 2-1 Three-conductor AC Power Cable . 2-1 DC Plug . 2-2 Battery Installation
15、. 2-2 Claims . 2-2 Repacking for Shipment . 2-2 I11 OPERATION . 3-1 3.1 . Introduction . 3-1 3.3 . Controls and Connectors . 3-1 3.5 . Beam Finder . 3-1 3.7 . Scale Illumination . 3-1 3.9 . Trace Align . 3-1 3.11 . Calibrator . 3-1 3.13 . Focus and Astigmatism . 3-1 3.15 . Coupling . 3-1 3.17 . Disp
16、lay . 3-4 3.24 . Trig . 3-4 3.26 . B Polarity . 3-4 3.28 . Sweep Display . 3-4 3.30 . Ext Horiz Input . 3-4 3.32 . Main Sweep . 3-4 3.34 . Mixed Sweep . 3-4 3.36 . Delayed Sweep . 3-4 3.38 . Time/Div . 3-4 3.40 . Vernier . 3-4 3.42 . Trigger Level . 3-4 3.44 . Trigger Holdoff 3-4 3.46 . Slope . 3.4
17、. Section Page 3.48 . 3.51 . 3.54 . 3.56 . 3.58 . 3.59 . 3.61 . 3.63 . 3.65 . 3.67 . 3.69 . 3.71 . 3.73 . 3.75 . 3.77 . 3.80 . Sweep Mode . 3-5 Trigger Selection . 3-5 Magnetic Interference . 3-5 Battery Recharge Operation . 3-5 Preoperational Adjustments . 3-5 Initial Turn.on . 3-5 Focus and Astigm
18、atism Adjust . 3-6 Operating Procedures . 3-6 Operators Performance Check . 3-6 Operating Information . 3-7 Auto Versus Norm . 3-7 Auto Versus Trig . 3-7 AC Versus DC . 3-7 Mixed Sweep . 3-7 Delayed Sweep . 3-7 Line Sync . 3-7 IV PRINC111,ES OF OPERATION . 4-1 4.1 . 4.3 . 4.6 . 4 . 8 . 4- 10 . 4-12
19、4.14 . 4- 16 . 4.21 . 4.24 . 4.27 . Introduction . 4-1 Block Diagram Discussion . 4-1 Input Attenuator . 4-1 Vertical Ircamplifier . 4-1 1)cllay I.ine . 4-1 Vertical Output Amplifier . 4-1 Trigger Circuits . 4-1 M ai n In t egr a t o r . 4 . 1 Holdoff and Comparator . 4-2 I )el ay ed Integra tor . 4