1、 HP Archive This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! On-line curator: John Miles, KE5FX RadioFans.CN 收音机爱 好者资料库 m HEWLETT PACKARD OPERATING AND SERVICE HAHUAL M O D E L 3 0 4 8 A O P T I O N K 2 3 D C B L O C K I N G F I L T E R How To
2、Use This Manual This Manual should be used in conjunction with the HP 3048A Operating Manual, HP Part Number 03048-90001 (printed March 1988), the HP 3048A Reference Manual, HP Part Number 03048-90002 (printed June 1988), and the HP 3048A System Calibration Manual, HP Part Number 03048-90015 (printe
3、d January 1988). Applicable Serial Numbers This Manual applies to instruments with serial number prefixes greater than or equal to 2820A. Updates to this Hanual Periodically, changes are made to this Manual to correct errors in the original printing and to include Option improvements. Corrections ar
4、e indicated by a mark at the right-hand edge of the modified text. The mark used is keyed to the date the corrections are added (found on this cover page below the issue date). Operating and Service Manual Issued December 1988 HP Part Number 03048-92036 Updated June 1989 Updated April 1990 Copyright
5、 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. RadioFans.CN 收音机爱 好者资料库 m HEWLETT PACKARD 3048A Option K23 03048-92036 Page 2 of 20 SECTION h 6ENERAI IUFPRMATION 1-1. INTRODUCTION This manual contains information required to install, o
6、perate, and service the Hewlett-Packard Model 3048A Option K23 DC Blocking Filter, an optional accessory for the HP 3048A Phase Noise Measurement System. The DC Blocking Filter Operating and Service Manual has five sections. The subjects addressed are: SECTION I GENERAL INFORMATION SECTION II OPERAT
7、ION SECTION III PERFORMANCE TESTS SECTION IV REPLACEABLE PARTS SECTION V SERVICE 1-2. SPECIFICATIONS Instrument specifications are listed in table 1-1. These specifications are the performance standards or limits against which the instrument may be tested. CHARACTERISTICS MAXIMUM INPUT DC FLATNESS T
8、able 1-1. Specifications PERFORMANCE LIMITS +/-30 V +/-0.5 dB CONDITIONS 5 Hz to 40 MHz o9 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. RadioFans.CN 收音机爱 好者资料库 WL-m HFWLPTT 3048A Option K23 Whn SFZI 03048-92036 %Lf!M PACKAR
9、D p 3 o f 2 0 1-3. DESCRIPTION The HP Model 3048A Option K23 DC Blocking Filter is an accessory to the HP 3048A Phase Noise Measurement System. It contains a blocking capacitor designed to allow noise measurements on power supplies with the HP 3048A. The Insertion loss of the DC Blocking Filter is t
10、ypically 6.0 dB when loaded by the 50 ohm input of the HP 11848A Phase Noise Interface. The switch on the front cover can be set for either a positive or negative power supply. 1-4. INITIAL INSPECTION Inspect the shipping container. If the container and/or packing material is damaged, it should be k
11、ept until the contents of the shipment have been checked mechanically and electrically. If there is mechanical damage or if the instrument does not pass the performance tests, notify the nearest Hewlett-Packard office. Keep the damaged shipping materials (if any) for inspection by the carrier and a
12、Hewlett-Packard representative. 1-5. ACCESSORIES The accessories supplied with the HP 3048A Opt. K23 are listed below: IMPEDANCE MATCHING NETWORK 03048-62015 CALIBRATION LOAD 03048-62016 CALIBRATION CABLES (2) 03048-62017 ADAPTER SMA(F) TO SMC(F) (3) 1250-1694 ADAPTER SMA(M) TO SMC(F) (1) 1250-1697
13、ADAPTER RT ANGLE SMA(M) TO SMA(M) 1250-1397 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. tvi HEWLETT PACKARD 3048A Option K23 03048-92036 Page 4 of 20 SECTION II. OPERATION 2-1. APPLICATIONS The HP 3048A Opt. K23 DC Blockin
14、g Filters main purpose is to make noise measurements on power supplies or any other baseband noise source that has a DC offset. The DC Blocking Filter will enable the HP 3048A to have maximum dynamic range. The HP 3048A has two methods of measuring baseband noise. Noise Measurement Using the HP 3561
15、A Only, and Baseband Noise Measurement. These methods are described in the HP 3048A Phase Noise Measurement System Reference Manual (HP part number 03048-90002), Section 2, Measurement Definitions. 2-1. CONNECTIONS Connect the output of the baseband noise source to the input of the DC Blocking Filte
16、r. The output of the DC Blocking Filter is connected to either the NOISE INPUT of the HP 11848A or directly to the input of the HP 3561A. The best results will be obtained when semirigid coaxial cables are used to connect the components used in the measurement and should be used whenever possible. A
17、 equipment setup diagram is given for each type of baseband measurement that the HP 3048A can perform. The setup diagrams for Noise Measurement Using the HP 3561A Only and Baseband Noise Measurement are shown in figure 2-1 and figure 2-2 respectively. Table 2-1 gives the insertion loss and low frequ
18、ency cutoff for each of these measurement types. Table 2-1. HP 3048A Option K23 Insertion Loss and Low Freq. Cutoff HP 3048A MEASUREMENT TYPE INSERTION LOSS LOW FREQUENCY CUTOFF Baseband Noise HP 3561A Only 6.0 dB typical B key on the HP 3585A/B. 5. Press the A-B key on the HP 3585A/B to activate th
19、e trace. 6. Turn off the B trace by pressing the VIEW B key on the HP 3585A/B. There should only be one trace on the HP 3585A/B CRT and it should be a straight line in the middle of the screen. 7. Replace the Calibration Load with the Opt. K23 DC Blocking Filter as shown in Figure 3-2. HP3585A/B SPE
20、CTOUM ANALYZER Mwawa MKHM * 30*8* OPI -23 KBlOOONGflLl Figure 3-2. Setup for Flatness Test with HP 3585A/B Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m HEWLETT PACKARD 3048A Option K23 03048-92036 Page 9 of 20 8. Set the
- 配套讲稿: