1、I . : HP Archive . . This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! . . On-line curator: Tony Gerbic RadioFans.CN 收音机爱 好者资料库 INSTRUCTION AND O P E R A T I N G MANUAL F O R MODEL 540A TRANSFER OSCILLATOR Serial 492 and Above Copyright 1955 by
2、Hcwlett-Packard Company The information contained in this booklet i s intended for the operation and main- tenance of Hewlett-Packard equipment and i s not to be used otherwiseor reproduced without the writtenconsentof theHewlett- Packard Company. HEWLETT-PACKARD COMPANY 275 PAGE MILL ROAD, PAL0 ALT
3、O, CALIFORNIA, U. S. A. 540A003-2 RadioFans.CN 收音机爱 好者资料库 SPECIFICATIONS FOR I MODEL 540A TRANSFER OSCILLATOR GENERAL FREQUENCY RANGE: TYPE INPUT SIGNAL: INPUT SIGNAL LEVEL: ACCURACY: AUXILIARY EQUIPMENT: OSCILLATOR FUNDAMENTAL FREQ. RANGE: HARMONIC FREQ. RANGE: STABILITY: DIAL: VERNIER DIAL: OUTPUT
4、: ATTENUATOR RANGE: INPUT IMPEDANCE: AMPLIFIER 10 MC to 5,000 MC. (10 MC to 12,000 MC or high- e r with external detector. ) CW, AM, FM, or pulse. 50 mv to 5 v peak cw. 50v peak pulse, max. eq. CW power 1/2 w at 50 ohms. Depends on stability of unknown signal and pulse length - see text. Model 524B
5、Electronic Counter. Model 525B Frequency Converter Unit. Model 150A Oscilloscope (for pulse measure- ments). 100 MC to 220 MC. Above 12,000 MC. Less tkan 0.002?0 change per minute after 30 minute warmup. Six inch diameter, calibrated in 1 MC increments. Accuracy: fl/27?0. Mechanical: Approx. 9:l Ele
6、ctrical: Approx 2 v into 50 - Adjusted for optimum crystal harmonic generation. Approx. +125 parts per million Minimum attenuation is not more than 20 db and maximum attenuation is not less than 80 db at frequencies from 1 kmc to 5 kmc, below 1 kmc minimum attenuation and attenuation range in- creas
7、e. At 100 rnc minimum attenuation is at least 35 db. 50 ohms, SWR: 1.5 max. at 1 KMC; 3 max. at 5 KMC. GAIN: BANDWIDTH: HIGH FREQUENCY CONTROL: LOW FREQUENCY CONTROL: MAX. UNDJSTORTED OUTPUT: Adjustable, 40 db m a x 100 cycles to 2 megacycles. 3 db point adjustable from below 1 KC to above 2 MC. 3 d
8、b point switched from 100 cycles to below 10 KC then continuously adjustable to above 400 KC. 1 volt rms useable signal across 1,000 a load. J . . RadioFans.CN 收音机爱 好者资料库 SPECIFICATIONS FOR MODEL 540A TRANSFER OSCILLATOR (Contd) OS CLLLOS COPE (S e If Contained) FREQ. RANGE: VERTICAL DEFLECTION SENS
9、ITIVITY: HORIZONTAL SWEEP: TUBE: MISCELLANEOUS CONNECTORS : SIZE: WEIGHT: POWER SUPPLY: ACCESSORIES FURNISHED: ACCESSORIES AVAILABLE: AUXILIARY EQUIPMENT: 100 cps to 200 KC. 5 MV rms per inch. External, lv per inch, frequency response 20 cps to 5 KC; Internal sine wave, at power supply frequency wit
10、h phase control. 2 inch diameter. Input, type N; all others type BNC. Cabinet Mount: 20-1/2 wide, 12-1/211 high, 15 - 1 /4 deep. Rack Mount: 19 wide, 10-1/2 high, 15- 1/4 deep. Cabinet Mount: 42 lbs. ; shipping weight 63 lbs. Rack Mount: 35 lbs. ; shipping weight 56 lbs. 115/230v rms *lo%, 50/1,000
11、cps, approximately 11owatts. eAC-16K Cable Assembly, 4 feet of RG-58/U 50 ohm coaxial cable terminated at each end with UG-88/U Type BNC male connectors. QAC-16C Cable Assembly, 6 feet of RG-9A/U 50 ohm coaxial cable terminated at one end with a UG-21B/U Type N Male connector and with a UG-23B/U Typ
12、e N female connector at the other. (For use at frequencies below 4,000 MC. ) AC-16D Cable Assembly, 44 inches of RG-58/U 50 ohm coaxial cable terminated at one end only with a UG-88/U Type BNC male connector. $2.65 AC-16F Cable Assembly 6 feet of RG-9A/U 50 ohm coaxial cable terminated at each end w
13、ith UG-21B/U Type N male connectors. use at frequencies below 4,000 MC. ) AC-l6Q Cable Assembly, 6 feet of specially treated RG-SA/U 50 ohm coaxial cable term- inated at each end with UG-ZlB/U Type N male connectors. Each cable is tested and selected for minimum SWR at frequencies above 4,000 MC . (
14、For Model 524B Electronic Counter, cabinet mount. 0 Model 524BR Electronic Counter, rack mount. Model 525B Frequency Converter Unit, 100-220 MC. i Model 440A Detector Mount. TABLE OF CONTENTS MODEL 540A TRANSFER OSCILLATOR Page Section I GENERAL DESCRIPTION 1-1 Description . . . . . . . . . . . . .
15、. . . . . 1-1 1-2 Principle of Operation . . . . . . . . . . . . . 1-1 1-3 Accuracy of Measurement . . . . . . . . . . . 1-2 1-4 Accessories Furnished . . . . . . . . . . . . 1-2 Section I1 OPERATING INSTRUCTIONS 2-1 2 -2 2 -3 2 -4 2 -5 2 -6 2 -7 2 -8 2 -9 2-10 Ins tallation . . . . . . . . . . . .
16、. . . . . . Power Line Voltage and Frequency . Frequency Measurement. General . . . . . . . Measuring CW Frequencies . . . . . . . . . . Measuring Frequency-Modulated R-F Signals . . . Measuring Pulsed R-F Signals . . . . . . . . . Inc r eas ing Sensitivity . . . . . . . . . . . . . . Operating the
17、540A Above 5 KMC- The Frequency Control Jack on the Rear Panel . . Measurement Precautions . . . . . . . . . . . Special Applications of the 540A Transfer Oscillator . . . . . . . . . . . . . . . . . . 2-1 2-1 2-1 2-6 2 -9 2-11 2-15 2-15 2-17 2-17 Section 1 1 1 THEORY OF OPERATION 3-1 BlockDiagram .
18、 . . . . . . . . . . . . . . . 3-1 3 -2 100 to 220 MC Oscillator . . . . . . . . . . . . 3-2 3-3 Input Attenuator . . . . . . . . . . . . . . . . 3-3 Mixer . 3-3 3 -4 3-5 Video Amplifier . . . . . . . . . . . . . . . . 3-3 3-6 Vertical Amplifier for the Oscilloscope . . . . . 3-4 3-7 Horizontal Ampl
19、ifier and Sweep Circuits . . . . . 3-4 3-8 Power Supply . . . . . . . . . . . . . . . . 3-5 Section IV SERVICE INSTRUCTIONS 4-1 Removing the Instrument Cabinet . . . . . . . . 4-1 4-2 Tube Replacement . . . . . . . . . . . . . . . 4-1 4-3 Checking and Adjusting the Power Supply . . . . . 4-2 Horizon
20、tal Positioning . . . . . . . . . . . . . 4-4 4-5 Calibrating the Main Tuning Dial . . . . . . . . 4-4 4-6 Replacing the Crystal Diode Mixer . . . . . . . 4-5 4-7 Trouble Shooting . . . . . . . . . . . . . . . 4-5 4-4 Adjusting the Oscilloscope Vertical and . Section V TABLE OF REPLACEABLE PARTS 5 -
21、2 SECTION I GENERAL DESCRIPTION 1-1 DESCRIPTION The Model 540A Transfer Oscillator is a precision frequency- measuring instrument which can be used with the 524B Elec- tronic Counter and 525B Frequency Converter to measure frequen- cies from 100 megacycles to over 5,000 megacycles with frequency- st
22、andard accuracy and with better than 0. 1-volt sensitivity. Types of r-f signals that can be measured include continuous-wave, fre- quenc y -modulate d, amplitude -modulated and pulse -modulate d signals, and signals containing troublesome amounts of noise. In addition, the residual frequency-modula
23、tion in c -w signals, the limits of incidental frequency-deviation in amplitude -modulated signals and the limits of frequency deviation in frequency-modulated signals can also be measured. As a result of the Transfer Oscillator method of making a frequency measurement and the use of an oscilloscope
24、 to observe the beat- frequency, each of the above types of signals is easily distinguished and in all cases the zero-beat is quickly determined. By using two 440A Tunable Detectors with the 540A, the range of fre- quency measurement is extended to above 12,400 megacycles with the same 0. 1-volt sen
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-540A-Manual 电路图 HP 540 Manual
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf