1、I . : HP Archive . . This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! . . On-line curator: Tony Gerbic RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 SPECIFICATIONS PRELIMINARY CHECKOUT 1. Controls and Terminals 2. Testing PUTTING THE SUPPLY I
2、NTO SERVICE 1. Mode of Operation 2. Special Considerations INDEX MEASURING THE PERFORMANCE OF THE SUPPLY MAINTENANCE CIRCUIT DESCRIPTION SERVICE 1 . Procedure 2. Trouble Shooting 3. Table I. 4. Table 11. 5 . Alignment Procedure PARTS LIST DRAWINGS Fig. 1. Fig. 2. Fig. 3. Fig. 4. Fig. 5 . Fig. 6. Fig
3、. 8 . Fig. 9 . Rear Terminal Connections Normal Operation Remote Programming, Local Sensing Remote Sensing, Local Programming Remote Sensing, Remote Programming Test Data Block Diagram Schema tic Page 2 4 4 5 7 8 8 9 11 11 12 14 15 17 RadioFans.CN 收音机爱 好者资料库 I I I I 1 I i I 1 I I i i I i i I I I I i
4、 I I j I J i I I I SPECIFICATIONS Input: 105-125VAC, single phase 60 cps, 3.9A and 255W at 117VAC input and full output . Output: 0-320 volts, 0-0.6 amperes Load Regulation: Less than 0 . 007% or 20 mv change (whichever is greater) for a 0.6 ampere load change. Line Regulation: Less than 0.007% or 2
5、0 mv change (whichever is greater) for 105 to 125 volt line change. Ripple and Noise: Less than 2 millivolts rms. Plus or minus output terminal must be grounded through a low impedance path. Maximum Operating Temperature: 5OoC Temperature Coefficient: Output voltage change per degree Centigrade is l
6、ess than 0.03% plus 1.5 millivolts. 3. Stability: The total drift for 8 hours (after 30 minutes warmup) at a constant ambient temperature is less than 0 . 1% plus 5 millivolts. Internal Impedance: Less than 0.04 ohms from DC to 1 Kc. Less than 0.2 ohms from 1 K c to 10 Kc. Less than 1.0 ohms from 10
7、 Kc to 1 Mc. Less than 10 ohms from 1 Mc to 10 Mc. Transient Recovery Time: Less than 100psec is required for output voltage recovery to within 20 millivolts of the nominal output voltage following a 0 . 6 ampere change in output current. For this measurement, the nominal output voltage is defined a
8、s the mean between the no load and full load voltages. Overload Protection: An all-electronic, continuously acting current limit circuit protects the power supply for all overloads, including a short circuit placed directly across the output terminals. However, a fuse is placed in the output circuit
9、 to protect against an instantaneous short circuit at high output voltages. The unit may be safely turned on into a short circuit. Turn-on-Turn-off Transient: On output voltages above 10 volts, there will be no turn-on or turn-off overshoot and will be less than 0 . 2 of a volt at 10 volts or less o
10、utput. 2) Controls: A lO-turn potentiometer (with concentric knoblock) on the front panel makes possible continuous adjustment of the output voltage over the entire range from 0 to 320 volts. Meters: A 0-32OV voltmeter and 0-0.8A ammeter are provided. Output Terminals: An output terminal strip is lo
11、cated on the rear of the chassis. All power supply terminals are isolated from the chassis and either the positive or negative terminal may be connected to the chassis through a separate ground terminal located adjacent to the output terminals . Error Sensing Remote Programming and Remote Programmin
12、g . I ALIGNMENT PROCEDURE I 89 O A Step 1. High-Voltage Test I See Preliminary of Service Section and Figure 6A. Step 2 Preturn-on Adjustments A. Set voltmeter and ammeter to zero. B. Set programming control full clockwise. D. Check for proper fuses (DC 1 amp, AC 5 amp). E. Wire for normal operation
13、, see Figure 1. F. I C, Set line switch to off . I Disconnect main power rectifier from T3 (lugs 11 & 12) . 1 Step 3. Turn on Unit I Output voltage should rise to about 20 volts. Step 4. Connect A1 to +Output Output voltage should fall to zero. If 3 or 4.are not correct, check voltages 1 through 7 i
14、n Table I and check Q1, 2, 5, 7, 8 , 9 . i I 1 Step 5. Connect a 0-1 .O amp ammeter directly across the output terminals. Adjust P4 for . 8 ampere on external meter. Adjust P7 for 08 ampere on internal meter. Remove meter. I Step 6. Turn programming control down until supply goes into regulation-abo
15、ut 3/4 I turn from full counterclockwise. Rock control up and down. Connect an I , control circuit . oscilloscope between minus bus and test point 30. Waveform should shift left and right. See Figure 6B. Improper waveform indicates trouble in SCR Step 7. Turn control about one turn up from full coun
16、terclockwise . Connect scope between the cathode and gate of each SCR and observe waveforms as in Figure 6C. A very low on high pulse voltage usually indicates a defective SCR. I I 1 Step 80 Adjust output voltage to about 5 volts. Load supply to .65 amperes ard observe output voltage with scope. The
17、 peak-to-peak ripple should be less I than 300yv. Step 9. Turn off unit and reconnect the main rectifier bridge to lugs 11 and 12 on T3 . Set programming control to one turn from full clockwise. Turn on unit. Output voltage should rise to about 300 volts. Observe output voltage on scope, Ripple shou
18、ld not exceed 300yv peak-to-peak. I Step 10. Increase load on supply slowly. Output current meter should rise to 0.8 ampere then remain constant as the load resistance is decreased. P4 can be used to adjust the current limit. Step 11. Load supply from nearly zero current to .65 amperes at any voltag
19、e above 20 volts output. Measure the voltage between 28 and 27 with a voltmeter. It should drop from about 15 volts to about 1.3 volts as the current is in- creased from zero to about 150 ma and then remain nearly constant as the load current is further increased . Step 12, Set output voltage to abo
20、ut 320 volts. Vary line from 105 to 125. Load supply to .65 amps. Observe output of supply at its sensing terminals with digital voltmeter or potentiometric differential voltmeter such as a John Fluke Model 801H. Adjust P2 until output voltage shifts less than 2 mv as an immediate shift of line volt
21、age. Step 13. Apply and remove the .65 amp load. Observe output as in step 12. Adjust P1 until output voltage change is less than 2 mv. Step 14. Alternately apply and disconnect the -65 amp load (non-inductive) with a Mercury wetted relay at any frequency up to 100 cps (Relay-Clare type HGP 1002). O
22、bserve output voltage on scope at the sensing terminals. Adjust P3 until trace is similar to Figure 6D. Step 15. Turn line voltage to 125 volts. Remove load from supply, Pull QS from its socket. Observe output voltage on a multimeter. Adjust P5 for 400 volts output . Step 16. Turn off supply, replac
23、e 05, disconnect +S from A2, connect a 96K +1/2% 5 watt resistor between +S and Al. Turn on unit. Output voltage should rise to 320 volts +1/2%. If unit is outside of this value then turn off unit and remove R2 on the stand-off terminals and replace it with a resistance decade box. Turn on unit and
24、adjust the decade box for exactly 320 volts output . Substitute a fixed resistor for the decade box and recheck . DO not use a value less than 47K unless it has a temperature coefficient less than 100 ppm/OC. Adjust P6 until output voltmeter reads 320 volts. Step 17. Short output of the supply with